{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1367503283"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1367503283","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"IN VITRO BIOMECHANICAL TESTING AND COMPUTATIONALMODELING IN SPINE","abstract":"Two separate in vitro biomechanical studies were conducted on human cadaveric spines (Lumbar) to evaluate the stability following the implantation of two different spinal fixation devices; interspinous fixation device (ISD) and Hybrid dynamic stabilizers. ISD was evaluated as a stand-alone and in combination with unilateral pedicle rod system. The results were compared against the gold standard, spinal fusion (bilateral pedicle rod system). The second study involving the hybrid dynamic system, evaluated the effect on adjacent levels using a hybrid testing protocol. A robotic spine testing system was used to conduct the biomechanical tests. This system has the ability to apply continuous unconstrained pure moments while dynamically optimizing the motion path to minimize off-axis loads during testing. Thus enabling precise control over the loading and boundary conditions of the test. This ensures test reliability and reproducibility. We found that in flexion-extension, the ISD can provide lumbar stability comparable to spinal fusion. However, it provides minimal rigidity in lateral bending and axial rotation when used as a stand-alone. The ISD with a unilateral pedicle rod system when compared to the spinal fusion construct were shown to provide similar levels of stability in all directions, though the spinal fusion construct showed a trend toward improved stiffness overall. The results for the dynamic stabilization system showed stability characteristics similar to a solid all metal construct. Its addition to the supra adjacent level (L3- L4) to the fusion (L4- L5) indeed protected the adjacent level from excessive motion. However, it essentially transformed a 1 level into a 2 level lumbar fusion with exponential transfer of motion to the fewer remaining discs (excessive adjacent level motion).The computational aspect of the study involved the development of a spine model (single segment). The kinematic data from these biomechanical studies (ISD study) was then used to validate a finite element model of the spine.","abstract_html":"Two separate in vitro biomechanical studies were conducted on human cadaveric spines (Lumbar) to evaluate the stability following the implantation of two different spinal fixation devices; interspinous fixation device (ISD) and Hybrid dynamic stabilizers. ISD was evaluated as a stand-alone and in combination with unilateral pedicle rod system. The results were compared against the gold standard, spinal fusion (bilateral pedicle rod system). The second study involving the hybrid dynamic system, evaluated the effect on adjacent levels using a hybrid testing protocol. A robotic spine testing system was used to conduct the biomechanical tests. This system has the ability to apply continuous unconstrained pure moments while dynamically optimizing the motion path to minimize off-axis loads during testing. Thus enabling precise control over the loading and boundary conditions of the test. This ensures test reliability and reproducibility. We found that in flexion-extension, the ISD can provide lumbar stability comparable to spinal fusion. However, it provides minimal rigidity in lateral bending and axial rotation when used as a stand-alone. The ISD with a unilateral pedicle rod system when compared to the spinal fusion construct were shown to provide similar levels of stability in all directions, though the spinal fusion construct showed a trend toward improved stiffness overall. The results for the dynamic stabilization system showed stability characteristics similar to a solid all metal construct. Its addition to the supra adjacent level (L3- L4) to the fusion (L4- L5) indeed protected the adjacent level from excessive motion. However, it essentially transformed a 1 level into a 2 level lumbar fusion with exponential transfer of motion to the fewer remaining discs (excessive adjacent level motion).The computational aspect of the study involved the development of a spine model (single segment). The kinematic data from these biomechanical studies (ISD study) was then used to validate a finite element model of the spine.","abstract_has_math":false,"creators":["Prasath, Mageswaran"],"institution":"Cleveland State University","degree_name":"Doctor of Engineering","degree_level":"doctoral","degree_discipline":"Fenn College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["McLain, Robert"],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-27T04:12:47Z","subjects":["Biomechanics","Biomedical Research","Biomedical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1367503283","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1367503283","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1367503283","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1367503283","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["McLain, Robert"]},{"key":"dc:creator","label":"Author","values":["Prasath, Mageswaran"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fenn College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","Biomedical Research","Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1367503283"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Two separate in vitro biomechanical studies were conducted on human cadaveric spines (Lumbar) to evaluate the stability following the implantation of two different spinal fixation devices; interspinous fixation device (ISD) and Hybrid dynamic stabilizers. ISD was evaluated as a stand-alone and in combination with unilateral pedicle rod system. The results were compared against the gold standard, spinal fusion (bilateral pedicle rod system). The second study involving the hybrid dynamic system, evaluated the effect on adjacent levels using a hybrid testing protocol. A robotic spine testing system was used to conduct the biomechanical tests. This system has the ability to apply continuous unconstrained pure moments while dynamically optimizing the motion path to minimize off-axis loads during testing. Thus enabling precise control over the loading and boundary conditions of the test. This ensures test reliability and reproducibility. We found that in flexion-extension, the ISD can provide lumbar stability comparable to spinal fusion. However, it provides minimal rigidity in lateral bending and axial rotation when used as a stand-alone. The ISD with a unilateral pedicle rod system when compared to the spinal fusion construct were shown to provide similar levels of stability in all directions, though the spinal fusion construct showed a trend toward improved stiffness overall. The results for the dynamic stabilization system showed stability characteristics similar to a solid all metal construct. Its addition to the supra adjacent level (L3- L4) to the fusion (L4- L5) indeed protected the adjacent level from excessive motion. However, it essentially transformed a 1 level into a 2 level lumbar fusion with exponential transfer of motion to the fewer remaining discs (excessive adjacent level motion).The computational aspect of the study involved the development of a spine model (single segment). The kinematic data from these biomechanical studies (ISD study) was then used to validate a finite element model of the spine."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.141","4.9 MB"]},{"key":"dc:title","label":"Title","values":["IN VITRO BIOMECHANICAL TESTING AND COMPUTATIONALMODELING IN SPINE"]}]}],"canonical_facts":{"dc:contributor.committeechair":["McLain, Robert"],"dc:creator":["Prasath, Mageswaran"],"dc:date":["2012"],"dc:description":["Two separate in vitro biomechanical studies were conducted on human cadaveric spines (Lumbar) to evaluate the stability following the implantation of two different spinal fixation devices; interspinous fixation device (ISD) and Hybrid dynamic stabilizers. ISD was evaluated as a stand-alone and in combination with unilateral pedicle rod system. The results were compared against the gold standard, spinal fusion (bilateral pedicle rod system). The second study involving the hybrid dynamic system, evaluated the effect on adjacent levels using a hybrid testing protocol. A robotic spine testing system was used to conduct the biomechanical tests. This system has the ability to apply continuous unconstrained pure moments while dynamically optimizing the motion path to minimize off-axis loads during testing. Thus enabling precise control over the loading and boundary conditions of the test. This ensures test reliability and reproducibility. We found that in flexion-extension, the ISD can provide lumbar stability comparable to spinal fusion. However, it provides minimal rigidity in lateral bending and axial rotation when used as a stand-alone. The ISD with a unilateral pedicle rod system when compared to the spinal fusion construct were shown to provide similar levels of stability in all directions, though the spinal fusion construct showed a trend toward improved stiffness overall. The results for the dynamic stabilization system showed stability characteristics similar to a solid all metal construct. Its addition to the supra adjacent level (L3- L4) to the fusion (L4- L5) indeed protected the adjacent level from excessive motion. However, it essentially transformed a 1 level into a 2 level lumbar fusion with exponential transfer of motion to the fewer remaining discs (excessive adjacent level motion).The computational aspect of the study involved the development of a spine model (single segment). The kinematic data from these biomechanical studies (ISD study) was then used to validate a finite element model of the spine."],"dc:format":["application/pdf","p.141","4.9 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1367503283"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomechanics","Biomedical Research","Biomedical Engineering"],"dc:title":["IN VITRO BIOMECHANICAL TESTING AND COMPUTATIONALMODELING IN SPINE"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Fenn College of Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:12:47Z"}