{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1389795972"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1389795972","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Computational Study of Savonius Wind Turbine","abstract":"This project involves study of 2-Blade and 3-Blade Savonius vertical wind turbines positioned at different orientations. For a 2-Blade turbine the orientations considered were 0 degree, 45 degree, 90 degree and 135 degree in reference to the direction of the prevailing wind and for the 3-Blade turbine the orientations taken into account were 0 degree, 30 degree, 60 degree and 90 degree in reference to the direction of the prevailing wind. The basic aim of this thesis was to study how the two designs are different from each other and which design produces more power when applied with constant wind velocity of 10mps. Computational Fluid Dynamics (CFD) analyses were conducted for every case to find out the torque and power generated by the turbines for each orientation. To ensure the accuracy of the results, CFD techniques were applied using Gambit 2.2.30 and Fluent 6.2.16. All cases were run using “transition-SST” flow model and the faces were meshed using `Quadrilateral Pave’ meshing scheme. The turbine was also tested for varying wind velocities of 5mps, 20mps, and 30mps for a constant orientation of turbine. The results were later compared and graphs were created for easy comparison of power and torque generated by turbines at different velocities. Maximum change in pressure occurs when 2-Blade turbine in perpendicular to direction of wind flow direction i.e. at 90 degree and when 3-Blade turbine is at 60 degree orientation. The 2-Blade Turbine generates higher value of torque (215.28 N) as compared to 3-Blade turbine, generating torque of value 110.92 N for any given constant wind velocity; 30mps in this case. This information can help the designer of the system to select the proper wind turbine considering the efficiency and stability along with other factors.","abstract_html":"This project involves study of 2-Blade and 3-Blade Savonius vertical wind turbines positioned at different orientations. For a 2-Blade turbine the orientations considered were 0 degree, 45 degree, 90 degree and 135 degree in reference to the direction of the prevailing wind and for the 3-Blade turbine the orientations taken into account were 0 degree, 30 degree, 60 degree and 90 degree in reference to the direction of the prevailing wind. The basic aim of this thesis was to study how the two designs are different from each other and which design produces more power when applied with constant wind velocity of 10mps. Computational Fluid Dynamics (CFD) analyses were conducted for every case to find out the torque and power generated by the turbines for each orientation. To ensure the accuracy of the results, CFD techniques were applied using Gambit 2.2.30 and Fluent 6.2.16. All cases were run using “transition-SST” flow model and the faces were meshed using `Quadrilateral Pave’ meshing scheme. The turbine was also tested for varying wind velocities of 5mps, 20mps, and 30mps for a constant orientation of turbine. The results were later compared and graphs were created for easy comparison of power and torque generated by turbines at different velocities. Maximum change in pressure occurs when 2-Blade turbine in perpendicular to direction of wind flow direction i.e. at 90 degree and when 3-Blade turbine is at 60 degree orientation. The 2-Blade Turbine generates higher value of torque (215.28 N) as compared to 3-Blade turbine, generating torque of value 110.92 N for any given constant wind velocity; 30mps in this case. This information can help the designer of the system to select the proper wind turbine considering the efficiency and stability along with other factors.","abstract_has_math":false,"creators":["Chinchore, Asmita C."],"institution":"Cleveland State University","degree_name":"Master of Science in Mechanical Engineering","degree_level":"masters","degree_discipline":"Fenn College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Rashidi, Majid"],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-27T04:39:15Z","subjects":["Mechanical Engineering","Savonius Wind Turbine","Wind Turbines","2-Blade Turbine","3-Blade Turbine","CFD","Betz Limit","Fluid Flow Analysis","Ansys","Torque","Power"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1389795972","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1389795972","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1389795972","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1389795972","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Rashidi, Majid"]},{"key":"dc:creator","label":"Author","values":["Chinchore, Asmita C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fenn College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Savonius Wind Turbine","Wind Turbines","2-Blade Turbine","3-Blade Turbine","CFD","Betz Limit","Fluid Flow Analysis","Ansys","Torque","Power"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1389795972"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This project involves study of 2-Blade and 3-Blade Savonius vertical wind turbines positioned at different orientations. For a 2-Blade turbine the orientations considered were 0 degree, 45 degree, 90 degree and 135 degree in reference to the direction of the prevailing wind and for the 3-Blade turbine the orientations taken into account were 0 degree, 30 degree, 60 degree and 90 degree in reference to the direction of the prevailing wind. The basic aim of this thesis was to study how the two designs are different from each other and which design produces more power when applied with constant wind velocity of 10mps. Computational Fluid Dynamics (CFD) analyses were conducted for every case to find out the torque and power generated by the turbines for each orientation. To ensure the accuracy of the results, CFD techniques were applied using Gambit 2.2.30 and Fluent 6.2.16. All cases were run using “transition-SST” flow model and the faces were meshed using `Quadrilateral Pave’ meshing scheme. The turbine was also tested for varying wind velocities of 5mps, 20mps, and 30mps for a constant orientation of turbine. The results were later compared and graphs were created for easy comparison of power and torque generated by turbines at different velocities. Maximum change in pressure occurs when 2-Blade turbine in perpendicular to direction of wind flow direction i.e. at 90 degree and when 3-Blade turbine is at 60 degree orientation. The 2-Blade Turbine generates higher value of torque (215.28 N) as compared to 3-Blade turbine, generating torque of value 110.92 N for any given constant wind velocity; 30mps in this case. This information can help the designer of the system to select the proper wind turbine considering the efficiency and stability along with other factors."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","3.96 MB"]},{"key":"dc:title","label":"Title","values":["Computational Study of Savonius Wind Turbine"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Rashidi, Majid"],"dc:creator":["Chinchore, Asmita C."],"dc:date":["2013"],"dc:description":["This project involves study of 2-Blade and 3-Blade Savonius vertical wind turbines positioned at different orientations. For a 2-Blade turbine the orientations considered were 0 degree, 45 degree, 90 degree and 135 degree in reference to the direction of the prevailing wind and for the 3-Blade turbine the orientations taken into account were 0 degree, 30 degree, 60 degree and 90 degree in reference to the direction of the prevailing wind. The basic aim of this thesis was to study how the two designs are different from each other and which design produces more power when applied with constant wind velocity of 10mps. Computational Fluid Dynamics (CFD) analyses were conducted for every case to find out the torque and power generated by the turbines for each orientation. To ensure the accuracy of the results, CFD techniques were applied using Gambit 2.2.30 and Fluent 6.2.16. All cases were run using “transition-SST” flow model and the faces were meshed using `Quadrilateral Pave’ meshing scheme. The turbine was also tested for varying wind velocities of 5mps, 20mps, and 30mps for a constant orientation of turbine. The results were later compared and graphs were created for easy comparison of power and torque generated by turbines at different velocities. Maximum change in pressure occurs when 2-Blade turbine in perpendicular to direction of wind flow direction i.e. at 90 degree and when 3-Blade turbine is at 60 degree orientation. The 2-Blade Turbine generates higher value of torque (215.28 N) as compared to 3-Blade turbine, generating torque of value 110.92 N for any given constant wind velocity; 30mps in this case. This information can help the designer of the system to select the proper wind turbine considering the efficiency and stability along with other factors."],"dc:format":["application/pdf","3.96 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1389795972"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Savonius Wind Turbine","Wind Turbines","2-Blade Turbine","3-Blade Turbine","CFD","Betz Limit","Fluid Flow Analysis","Ansys","Torque","Power"],"dc:title":["Computational Study of Savonius Wind Turbine"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Fenn College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:39:15Z"}