{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1390322545"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1390322545","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"GRADIENT CHROMATOFOCUSING AND REVERSED PHASE HPLC IN PROTEIN ANALYSIS AND LC-MS/MS DETERMINATION OF THIAZOLIDINEDIONE NL-1 IN MOUSE SERUM AND BRAIN","abstract":"Gradient chromatofocusing (GCF) is a technique developed using linear pH gradients on weak-anion exchange HPLC columns. GCF greatly extends the capabilities of chromatofocusing by overcoming the shortcomings of the conventional chromatofocusing technique. GCF has been interfaced to mass spectrometry in protein separations. Chapter 1 demonstrates the advantage of GCF technique over reversed-phase (RP) HPLC in protein analysis. All RP protein peaks were eluted in a narrower region (40 &#x2013; 60% organic in a gradient) of the gradient compared to GCF, in which the proteins peaks were distributed along the entire length of the gradient due their differences in iso-electric points. Regarding peak widths, some had narrower widths with RP, others with GCF. The median, average peak widths for both the techniques were similar, however, overall, GCF is advantageous when compared with RP technique in the separation of proteins. Chapter 2 demonstrates a new procedure for characterizing weak anion-exchange (WAX) HPLC columns. Peak figures-of-merit results from injection of the 100 &#xb5;M NaNO3 standard were compared to that of injections toluene recommended by the manufacturer (20 mM toluene) has reveled that the peak width increases by 50% for the NaNO3 while the increase in toluene peak width is 30%. And, the shift in the retention time of 100 &#xb5;M NaNO3 from 3.17 mins to 1.52 mins beginning and after extensive use respectively has shown that 52% of function ion-exchange sites has been lost after an extensive usage. Chapter 3, 4 and 5 demonstrates developing a quantitative LC-MS/MS method for determination of thiazolidinedione (TZD) mitoNEET ligand NL-1 in mouse serum and its pharmacokinetic applications. A sensitive LC-MS/MS assay has been developed and validated for quantification of NL-1 {5-[(3,5-di-tert-butyl-4-hydroxyphenyl)methyl]-1,3-thiazolidine-2,4-dione} in mouse serum. The method is suitable for pharmacokinetic (PK) studies of the parent drug NL-1 based on the preliminary serum results from dosed NL-1 mouse studies. The key pharmacokinetic parameters of NL-1 in its serum and brain concentration &#x2013;were shown good penetration of drug into mice brain, More extensive metabolite studies should be performed as a part of future studies in order to investigate the fate of the analyte.","abstract_html":"Gradient chromatofocusing (GCF) is a technique developed using linear pH gradients on weak-anion exchange HPLC columns. GCF greatly extends the capabilities of chromatofocusing by overcoming the shortcomings of the conventional chromatofocusing technique. GCF has been interfaced to mass spectrometry in protein separations. Chapter 1 demonstrates the advantage of GCF technique over reversed-phase (RP) HPLC in protein analysis. All RP protein peaks were eluted in a narrower region (40 &amp;#x2013; 60% organic in a gradient) of the gradient compared to GCF, in which the proteins peaks were distributed along the entire length of the gradient due their differences in iso-electric points. Regarding peak widths, some had narrower widths with RP, others with GCF. The median, average peak widths for both the techniques were similar, however, overall, GCF is advantageous when compared with RP technique in the separation of proteins. Chapter 2 demonstrates a new procedure for characterizing weak anion-exchange (WAX) HPLC columns. Peak figures-of-merit results from injection of the 100 &amp;#xb5;M NaNO3 standard were compared to that of injections toluene recommended by the manufacturer (20 mM toluene) has reveled that the peak width increases by 50% for the NaNO3 while the increase in toluene peak width is 30%. And, the shift in the retention time of 100 &amp;#xb5;M NaNO3 from 3.17 mins to 1.52 mins beginning and after extensive use respectively has shown that 52% of function ion-exchange sites has been lost after an extensive usage. Chapter 3, 4 and 5 demonstrates developing a quantitative LC-MS/MS method for determination of thiazolidinedione (TZD) mitoNEET ligand NL-1 in mouse serum and its pharmacokinetic applications. A sensitive LC-MS/MS assay has been developed and validated for quantification of NL-1 {5-[(3,5-di-tert-butyl-4-hydroxyphenyl)methyl]-1,3-thiazolidine-2,4-dione} in mouse serum. The method is suitable for pharmacokinetic (PK) studies of the parent drug NL-1 based on the preliminary serum results from dosed NL-1 mouse studies. The key pharmacokinetic parameters of NL-1 in its serum and brain concentration &amp;#x2013;were shown good penetration of drug into mice brain, More extensive metabolite studies should be performed as a part of future studies in order to investigate the fate of the analyte.","abstract_has_math":false,"creators":["Pedada, Kiran K., Mr"],"institution":"Cleveland State University","degree_name":"Doctor of Philosophy in Clinical-Bioanalytical Chemistry","degree_level":"doctoral","degree_discipline":"College of Sciences and Health Professions","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Anderson , David"],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-27T04:39:15Z","subjects":["Chemistry","Analytical Chemistry"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1390322545","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1390322545","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1390322545","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1390322545","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Anderson , David"]},{"key":"dc:creator","label":"Author","values":["Pedada, Kiran K., Mr"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Sciences and Health Professions"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy in Clinical-Bioanalytical Chemistry"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry","Analytical Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1390322545"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Gradient chromatofocusing (GCF) is a technique developed using linear pH gradients on weak-anion exchange HPLC columns. GCF greatly extends the capabilities of chromatofocusing by overcoming the shortcomings of the conventional chromatofocusing technique. GCF has been interfaced to mass spectrometry in protein separations. Chapter 1 demonstrates the advantage of GCF technique over reversed-phase (RP) HPLC in protein analysis. All RP protein peaks were eluted in a narrower region (40 &#x2013; 60% organic in a gradient) of the gradient compared to GCF, in which the proteins peaks were distributed along the entire length of the gradient due their differences in iso-electric points. Regarding peak widths, some had narrower widths with RP, others with GCF. The median, average peak widths for both the techniques were similar, however, overall, GCF is advantageous when compared with RP technique in the separation of proteins. Chapter 2 demonstrates a new procedure for characterizing weak anion-exchange (WAX) HPLC columns. Peak figures-of-merit results from injection of the 100 &#xb5;M NaNO3 standard were compared to that of injections toluene recommended by the manufacturer (20 mM toluene) has reveled that the peak width increases by 50% for the NaNO3 while the increase in toluene peak width is 30%. And, the shift in the retention time of 100 &#xb5;M NaNO3 from 3.17 mins to 1.52 mins beginning and after extensive use respectively has shown that 52% of function ion-exchange sites has been lost after an extensive usage. Chapter 3, 4 and 5 demonstrates developing a quantitative LC-MS/MS method for determination of thiazolidinedione (TZD) mitoNEET ligand NL-1 in mouse serum and its pharmacokinetic applications. A sensitive LC-MS/MS assay has been developed and validated for quantification of NL-1 {5-[(3,5-di-tert-butyl-4-hydroxyphenyl)methyl]-1,3-thiazolidine-2,4-dione} in mouse serum. The method is suitable for pharmacokinetic (PK) studies of the parent drug NL-1 based on the preliminary serum results from dosed NL-1 mouse studies. The key pharmacokinetic parameters of NL-1 in its serum and brain concentration &#x2013;were shown good penetration of drug into mice brain, More extensive metabolite studies should be performed as a part of future studies in order to investigate the fate of the analyte."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.07 MB"]},{"key":"dc:title","label":"Title","values":["GRADIENT CHROMATOFOCUSING AND REVERSED PHASE HPLC IN PROTEIN ANALYSIS AND LC-MS/MS DETERMINATION OF THIAZOLIDINEDIONE NL-1 IN MOUSE SERUM AND BRAIN"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Anderson , David"],"dc:creator":["Pedada, Kiran K., Mr"],"dc:date":["2013"],"dc:description":["Gradient chromatofocusing (GCF) is a technique developed using linear pH gradients on weak-anion exchange HPLC columns. GCF greatly extends the capabilities of chromatofocusing by overcoming the shortcomings of the conventional chromatofocusing technique. GCF has been interfaced to mass spectrometry in protein separations. Chapter 1 demonstrates the advantage of GCF technique over reversed-phase (RP) HPLC in protein analysis. All RP protein peaks were eluted in a narrower region (40 &#x2013; 60% organic in a gradient) of the gradient compared to GCF, in which the proteins peaks were distributed along the entire length of the gradient due their differences in iso-electric points. Regarding peak widths, some had narrower widths with RP, others with GCF. The median, average peak widths for both the techniques were similar, however, overall, GCF is advantageous when compared with RP technique in the separation of proteins. Chapter 2 demonstrates a new procedure for characterizing weak anion-exchange (WAX) HPLC columns. Peak figures-of-merit results from injection of the 100 &#xb5;M NaNO3 standard were compared to that of injections toluene recommended by the manufacturer (20 mM toluene) has reveled that the peak width increases by 50% for the NaNO3 while the increase in toluene peak width is 30%. And, the shift in the retention time of 100 &#xb5;M NaNO3 from 3.17 mins to 1.52 mins beginning and after extensive use respectively has shown that 52% of function ion-exchange sites has been lost after an extensive usage. Chapter 3, 4 and 5 demonstrates developing a quantitative LC-MS/MS method for determination of thiazolidinedione (TZD) mitoNEET ligand NL-1 in mouse serum and its pharmacokinetic applications. A sensitive LC-MS/MS assay has been developed and validated for quantification of NL-1 {5-[(3,5-di-tert-butyl-4-hydroxyphenyl)methyl]-1,3-thiazolidine-2,4-dione} in mouse serum. The method is suitable for pharmacokinetic (PK) studies of the parent drug NL-1 based on the preliminary serum results from dosed NL-1 mouse studies. The key pharmacokinetic parameters of NL-1 in its serum and brain concentration &#x2013;were shown good penetration of drug into mice brain, More extensive metabolite studies should be performed as a part of future studies in order to investigate the fate of the analyte."],"dc:format":["application/pdf","2.07 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1390322545"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemistry","Analytical Chemistry"],"dc:title":["GRADIENT CHROMATOFOCUSING AND REVERSED PHASE HPLC IN PROTEIN ANALYSIS AND LC-MS/MS DETERMINATION OF THIAZOLIDINEDIONE NL-1 IN MOUSE SERUM AND BRAIN"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Sciences and Health Professions"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy in Clinical-Bioanalytical Chemistry"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:39:15Z"}