{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1391128419"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1391128419","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Live Cell Imaging to Investigate Bone Marrow Stromal Cell Adhesion and Migration on Titanium Surfaces: A Micro-Incubator <i>in vitro</i> Model","abstract":"Under this research, live cell imaging of osteoblast-like marrow stromal cells has been carried out on polished and nanotextured (NaOH-etched) medical-grade titanium alloy (Ti-6Al-4V) surfaces to examine cellular adhesion and migration. The purpose of this research was to:1)Build and assemble suitable hardware and software to conduct live cell imaging in a micro-incubator over an extended period of time.2)Monitor and record live osteoblast-like marrow stromal cells on polished and NaOH-etched titanium alloy surfaces from cell inoculation to about one week of culture. 3)Measure location, area and perimeter of individual cells as a function of time, and examine if, as compared / contrasted with the polished titanium surface, that the NaOH-etched titanium surface promotes adhesion and migration of cells.This was achieved by describing the mobility, morphology and overall behavior of osteoblast-like marrow stromal cells. During the cell growth cycles, data generated from image analysis included the cells’ center of mass (X,Y), their area, perimeter and shape as a function of incubation time. From the change in center of mass after each 15-minute interval, the real time speed of the cells was obtained. Major observations to support comparison studies between the surfaces determined that compared with polished titanium, NaOH-etched titanium promotes cellular filopodia growth, thus, promotes attachment. Filopodia provide cellular anchoring support and when prevalent, make cells more angular in shape. The median aspect ratio (length / width) of cells was found to be 1.38 on polished and 2.36 on NaOH-etched titanium. This, in addition to lower mean circularity shape factor values of 0.26 ± 0.03 on polished and 0.11 ± 0.01 on NaOH-etched titanium imply that the nanotextured surface promotes growth of cells more anchored to the substrate. This is also confirmed by increased perimeters of cells found on the NaOH-etched surface (950.92 ± 84.88 μm) compared with perimeter lengths of cells on the polished surface (668.55 ± 22.55 μm). Lastly, lower real time cell migration speed of 9 ± 1.2 μm / hour also suggests improved attachment of cells on NaOH-etched titanium with values speeds on the polished surface being 65 ± 19 μm / hour.","abstract_html":"Under this research, live cell imaging of osteoblast-like marrow stromal cells has been carried out on polished and nanotextured (NaOH-etched) medical-grade titanium alloy (Ti-6Al-4V) surfaces to examine cellular adhesion and migration. The purpose of this research was to:1)Build and assemble suitable hardware and software to conduct live cell imaging in a micro-incubator over an extended period of time.2)Monitor and record live osteoblast-like marrow stromal cells on polished and NaOH-etched titanium alloy surfaces from cell inoculation to about one week of culture. 3)Measure location, area and perimeter of individual cells as a function of time, and examine if, as compared / contrasted with the polished titanium surface, that the NaOH-etched titanium surface promotes adhesion and migration of cells.This was achieved by describing the mobility, morphology and overall behavior of osteoblast-like marrow stromal cells. During the cell growth cycles, data generated from image analysis included the cells’ center of mass (X,Y), their area, perimeter and shape as a function of incubation time. From the change in center of mass after each 15-minute interval, the real time speed of the cells was obtained. Major observations to support comparison studies between the surfaces determined that compared with polished titanium, NaOH-etched titanium promotes cellular filopodia growth, thus, promotes attachment. Filopodia provide cellular anchoring support and when prevalent, make cells more angular in shape. The median aspect ratio (length / width) of cells was found to be 1.38 on polished and 2.36 on NaOH-etched titanium. This, in addition to lower mean circularity shape factor values of 0.26 ± 0.03 on polished and 0.11 ± 0.01 on NaOH-etched titanium imply that the nanotextured surface promotes growth of cells more anchored to the substrate. This is also confirmed by increased perimeters of cells found on the NaOH-etched surface (950.92 ± 84.88 μm) compared with perimeter lengths of cells on the polished surface (668.55 ± 22.55 μm). Lastly, lower real time cell migration speed of 9 ± 1.2 μm / hour also suggests improved attachment of cells on NaOH-etched titanium with values speeds on the polished surface being 65 ± 19 μm / hour.","abstract_has_math":false,"creators":["Jensen, Rebecca Leah"],"institution":"Cleveland State University","degree_name":"Master of Science in Chemical Engineering","degree_level":"masters","degree_discipline":"Fenn College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Tewari, Surendra"],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-27T04:39:15Z","subjects":["Biomedical Engineering","marrow stromal cells","titanium implant","nano-texture","NaOH-etched surface","cellular attachment","shape factor","live cell imaging","micro-incubator","osteoblast cells","cell migration","cell morphology","aspect ratio","in vitro","green fluorescent protein"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1391128419","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1391128419","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1391128419","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1391128419","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Tewari, Surendra"]},{"key":"dc:creator","label":"Author","values":["Jensen, Rebecca Leah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fenn College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","marrow stromal cells","titanium implant","nano-texture","NaOH-etched surface","cellular attachment","shape factor","live cell imaging","micro-incubator","osteoblast cells","cell migration","cell morphology","aspect ratio","in vitro","green fluorescent protein"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1391128419"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Under this research, live cell imaging of osteoblast-like marrow stromal cells has been carried out on polished and nanotextured (NaOH-etched) medical-grade titanium alloy (Ti-6Al-4V) surfaces to examine cellular adhesion and migration. The purpose of this research was to:1)Build and assemble suitable hardware and software to conduct live cell imaging in a micro-incubator over an extended period of time.2)Monitor and record live osteoblast-like marrow stromal cells on polished and NaOH-etched titanium alloy surfaces from cell inoculation to about one week of culture. 3)Measure location, area and perimeter of individual cells as a function of time, and examine if, as compared / contrasted with the polished titanium surface, that the NaOH-etched titanium surface promotes adhesion and migration of cells.This was achieved by describing the mobility, morphology and overall behavior of osteoblast-like marrow stromal cells. During the cell growth cycles, data generated from image analysis included the cells’ center of mass (X,Y), their area, perimeter and shape as a function of incubation time. From the change in center of mass after each 15-minute interval, the real time speed of the cells was obtained. Major observations to support comparison studies between the surfaces determined that compared with polished titanium, NaOH-etched titanium promotes cellular filopodia growth, thus, promotes attachment. Filopodia provide cellular anchoring support and when prevalent, make cells more angular in shape. The median aspect ratio (length / width) of cells was found to be 1.38 on polished and 2.36 on NaOH-etched titanium. This, in addition to lower mean circularity shape factor values of 0.26 ± 0.03 on polished and 0.11 ± 0.01 on NaOH-etched titanium imply that the nanotextured surface promotes growth of cells more anchored to the substrate. This is also confirmed by increased perimeters of cells found on the NaOH-etched surface (950.92 ± 84.88 μm) compared with perimeter lengths of cells on the polished surface (668.55 ± 22.55 μm). Lastly, lower real time cell migration speed of 9 ± 1.2 μm / hour also suggests improved attachment of cells on NaOH-etched titanium with values speeds on the polished surface being 65 ± 19 μm / hour."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.145","158.25 MB"]},{"key":"dc:title","label":"Title","values":["Live Cell Imaging to Investigate Bone Marrow Stromal Cell Adhesion and Migration on Titanium Surfaces: A Micro-Incubator <i>in vitro</i> Model"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Tewari, Surendra"],"dc:creator":["Jensen, Rebecca Leah"],"dc:date":["2013"],"dc:description":["Under this research, live cell imaging of osteoblast-like marrow stromal cells has been carried out on polished and nanotextured (NaOH-etched) medical-grade titanium alloy (Ti-6Al-4V) surfaces to examine cellular adhesion and migration. The purpose of this research was to:1)Build and assemble suitable hardware and software to conduct live cell imaging in a micro-incubator over an extended period of time.2)Monitor and record live osteoblast-like marrow stromal cells on polished and NaOH-etched titanium alloy surfaces from cell inoculation to about one week of culture. 3)Measure location, area and perimeter of individual cells as a function of time, and examine if, as compared / contrasted with the polished titanium surface, that the NaOH-etched titanium surface promotes adhesion and migration of cells.This was achieved by describing the mobility, morphology and overall behavior of osteoblast-like marrow stromal cells. During the cell growth cycles, data generated from image analysis included the cells’ center of mass (X,Y), their area, perimeter and shape as a function of incubation time. From the change in center of mass after each 15-minute interval, the real time speed of the cells was obtained. Major observations to support comparison studies between the surfaces determined that compared with polished titanium, NaOH-etched titanium promotes cellular filopodia growth, thus, promotes attachment. Filopodia provide cellular anchoring support and when prevalent, make cells more angular in shape. The median aspect ratio (length / width) of cells was found to be 1.38 on polished and 2.36 on NaOH-etched titanium. This, in addition to lower mean circularity shape factor values of 0.26 ± 0.03 on polished and 0.11 ± 0.01 on NaOH-etched titanium imply that the nanotextured surface promotes growth of cells more anchored to the substrate. This is also confirmed by increased perimeters of cells found on the NaOH-etched surface (950.92 ± 84.88 μm) compared with perimeter lengths of cells on the polished surface (668.55 ± 22.55 μm). Lastly, lower real time cell migration speed of 9 ± 1.2 μm / hour also suggests improved attachment of cells on NaOH-etched titanium with values speeds on the polished surface being 65 ± 19 μm / hour."],"dc:format":["application/pdf","p.145","158.25 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1391128419"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","marrow stromal cells","titanium implant","nano-texture","NaOH-etched surface","cellular attachment","shape factor","live cell imaging","micro-incubator","osteoblast cells","cell migration","cell morphology","aspect ratio","in vitro","green fluorescent protein"],"dc:title":["Live Cell Imaging to Investigate Bone Marrow Stromal Cell Adhesion and Migration on Titanium Surfaces: A Micro-Incubator <i>in vitro</i> Model"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Fenn College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Chemical Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:39:15Z"}