{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1399314661"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1399314661","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Implementation and Field Testing of Improved Bridge Parapet Designs","abstract":"Premature cracking of concrete bridge parapets is a potentially complex problem, with a number of possible causes. Identifying the cause of premature cracking, and avoiding this problem in the future has several benefits, including: a potential cost savings for the district, improving the safety of these structures in future construction, and increasing the overall understanding of parapets. The objective of this study was to analyze the reasons for uncontrolled cracking in order to establish an improved parapet design, and provide recommendations to the Ohio Department of Transportation (ODOT) to prevent such cracking in the future. Previous research carried out a forensic investigation of four bridges in Northeast Ohio that exhibited extensive parapet cracking. In many cases, vertical cracks appeared between control joints. The study evaluated a number of hypotheses as to the causes of cracking, which were utilized in developing modifications to implement on test parapets for continued research. Potential factors examined in this study to continue research included: properties of the concrete mixtures used, construction methods, joint details, composite structural action, and durability of the concrete and reinforcement. A total of 22 test parapets were constructed as part of this project to evaluate different approaches to address premature cracking. In this study, 15 of the 22 parapets were constructed and examined. Not enough information was gathered thus far on the use of deeper saw cuts through glass fiber reinforced polymer (GFRP) reinforcement or field cut steel reinforcement to determine if this modification is a cost-effective choice. The parapets that included polypropylene fibers in the mixture did not perform any differently than the parapets without fiber in regards to early age cracking. Fibers may not have been needed with the concrete mixture that was used to prevent shrinkage or thermal cracking, but it may prove to be an efficient modification in the future by improving the durability and service life of parapets. Reducing the joint spacing over the negative moment regions of the bridge is an important modification that should be included in the design of concrete bridge parapets.","abstract_html":"Premature cracking of concrete bridge parapets is a potentially complex problem, with a number of possible causes. Identifying the cause of premature cracking, and avoiding this problem in the future has several benefits, including: a potential cost savings for the district, improving the safety of these structures in future construction, and increasing the overall understanding of parapets. The objective of this study was to analyze the reasons for uncontrolled cracking in order to establish an improved parapet design, and provide recommendations to the Ohio Department of Transportation (ODOT) to prevent such cracking in the future. Previous research carried out a forensic investigation of four bridges in Northeast Ohio that exhibited extensive parapet cracking. In many cases, vertical cracks appeared between control joints. The study evaluated a number of hypotheses as to the causes of cracking, which were utilized in developing modifications to implement on test parapets for continued research. Potential factors examined in this study to continue research included: properties of the concrete mixtures used, construction methods, joint details, composite structural action, and durability of the concrete and reinforcement. A total of 22 test parapets were constructed as part of this project to evaluate different approaches to address premature cracking. In this study, 15 of the 22 parapets were constructed and examined. Not enough information was gathered thus far on the use of deeper saw cuts through glass fiber reinforced polymer (GFRP) reinforcement or field cut steel reinforcement to determine if this modification is a cost-effective choice. The parapets that included polypropylene fibers in the mixture did not perform any differently than the parapets without fiber in regards to early age cracking. Fibers may not have been needed with the concrete mixture that was used to prevent shrinkage or thermal cracking, but it may prove to be an efficient modification in the future by improving the durability and service life of parapets. Reducing the joint spacing over the negative moment regions of the bridge is an important modification that should be included in the design of concrete bridge parapets.","abstract_has_math":false,"creators":["Kalabon, Amy Elizabeth"],"institution":"Cleveland State University","degree_name":"Master of Science in Civil Engineering","degree_level":"masters","degree_discipline":"Washkewicz College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Delatte, Norbert"],"committee_members":[],"year":2014,"date_issued":"2014-05-30","date_published":"2014-05-30","updated_at":"2026-11-27T04:39:37Z","subjects":["Civil Engineering","Engineering","Bridge parapets, concrete, cracking, improved parapet designs, joint details, deeper saw cuts, fibers, GFRP"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1399314661","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1399314661","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1399314661","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1399314661","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Delatte, Norbert"]},{"key":"dc:creator","label":"Author","values":["Kalabon, Amy Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-05-30"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Washkewicz College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","Engineering","Bridge parapets, concrete, cracking, improved parapet designs, joint details, deeper saw cuts, fibers, GFRP"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1399314661"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Premature cracking of concrete bridge parapets is a potentially complex problem, with a number of possible causes. Identifying the cause of premature cracking, and avoiding this problem in the future has several benefits, including: a potential cost savings for the district, improving the safety of these structures in future construction, and increasing the overall understanding of parapets. The objective of this study was to analyze the reasons for uncontrolled cracking in order to establish an improved parapet design, and provide recommendations to the Ohio Department of Transportation (ODOT) to prevent such cracking in the future. Previous research carried out a forensic investigation of four bridges in Northeast Ohio that exhibited extensive parapet cracking. In many cases, vertical cracks appeared between control joints. The study evaluated a number of hypotheses as to the causes of cracking, which were utilized in developing modifications to implement on test parapets for continued research. Potential factors examined in this study to continue research included: properties of the concrete mixtures used, construction methods, joint details, composite structural action, and durability of the concrete and reinforcement. A total of 22 test parapets were constructed as part of this project to evaluate different approaches to address premature cracking. In this study, 15 of the 22 parapets were constructed and examined. Not enough information was gathered thus far on the use of deeper saw cuts through glass fiber reinforced polymer (GFRP) reinforcement or field cut steel reinforcement to determine if this modification is a cost-effective choice. The parapets that included polypropylene fibers in the mixture did not perform any differently than the parapets without fiber in regards to early age cracking. Fibers may not have been needed with the concrete mixture that was used to prevent shrinkage or thermal cracking, but it may prove to be an efficient modification in the future by improving the durability and service life of parapets. Reducing the joint spacing over the negative moment regions of the bridge is an important modification that should be included in the design of concrete bridge parapets."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","4.18 MB"]},{"key":"dc:title","label":"Title","values":["Implementation and Field Testing of Improved Bridge Parapet Designs"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Delatte, Norbert"],"dc:creator":["Kalabon, Amy Elizabeth"],"dc:date":["2014-05-30"],"dc:description":["Premature cracking of concrete bridge parapets is a potentially complex problem, with a number of possible causes. Identifying the cause of premature cracking, and avoiding this problem in the future has several benefits, including: a potential cost savings for the district, improving the safety of these structures in future construction, and increasing the overall understanding of parapets. The objective of this study was to analyze the reasons for uncontrolled cracking in order to establish an improved parapet design, and provide recommendations to the Ohio Department of Transportation (ODOT) to prevent such cracking in the future. Previous research carried out a forensic investigation of four bridges in Northeast Ohio that exhibited extensive parapet cracking. In many cases, vertical cracks appeared between control joints. The study evaluated a number of hypotheses as to the causes of cracking, which were utilized in developing modifications to implement on test parapets for continued research. Potential factors examined in this study to continue research included: properties of the concrete mixtures used, construction methods, joint details, composite structural action, and durability of the concrete and reinforcement. A total of 22 test parapets were constructed as part of this project to evaluate different approaches to address premature cracking. In this study, 15 of the 22 parapets were constructed and examined. Not enough information was gathered thus far on the use of deeper saw cuts through glass fiber reinforced polymer (GFRP) reinforcement or field cut steel reinforcement to determine if this modification is a cost-effective choice. The parapets that included polypropylene fibers in the mixture did not perform any differently than the parapets without fiber in regards to early age cracking. Fibers may not have been needed with the concrete mixture that was used to prevent shrinkage or thermal cracking, but it may prove to be an efficient modification in the future by improving the durability and service life of parapets. Reducing the joint spacing over the negative moment regions of the bridge is an important modification that should be included in the design of concrete bridge parapets."],"dc:format":["application/pdf","4.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1399314661"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Civil Engineering","Engineering","Bridge parapets, concrete, cracking, improved parapet designs, joint details, deeper saw cuts, fibers, GFRP"],"dc:title":["Implementation and Field Testing of Improved Bridge Parapet Designs"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Washkewicz College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Civil Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:39:37Z"}