{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1449314893"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1449314893","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Determining the Transport Enhancement of Sodium Fluorescein in Mechanically-Loaded Canine Tibia","abstract":"Quantitative research concerning the impact of mechanical loading on the transport properties of bone has several critical applications. One such application is the effect of a microgravity environment, where the lack of mechanical forces on bone has been shown to negatively impact both growth and repair. A method has been developed in our lab that can potentially allow for the measurement of the effective permeability of large molecules (i.e., 300-15,000 Da in size) in bone tissue under both unloaded and mechanically loaded conditions. In proof-of-concept experiments, previous students have measured the effective diffusivity of the model solute, sodium fluorescein (376 Da) in a sample of unloaded bone tissue. A mechanical loading system has been modified to measure the effective permeability of sodium fluorescein for a bone beam undergoing four point bend testing in a bioreactor system in order to quantify the effect of mechanical loading on solute transport. The first goal of the present work was to validate that deflection of the bone beam was occurring at applied displacements of less than 40 µm. Once the deflection of the bone beam in the mechanical loading system was validated, the primary objective of measuring the transport parameter for sodium fluorescein in canine cortical bone under unloaded and loaded conditions could be achieved. The average value and standard error of this parameter for loaded samples was determined to be 3.70x10<sup>-8</sup>±1.31x10<sup>-8</sup> cm<sup>2</sup>s<sup>-1</sup> (n=5), and 6.59x10<sup>-9</sup>±2.46x10<sup>-9</sup> cm<sup>2</sup>s<sup>-1</sup> (n=4) for unloaded samples. Although a student’s t-test showed that the loaded and unloaded values were not statistically different (p=0.08), this is likely due to the small number of samples. These preliminary results do show that the transport parameter of sodium fluorescein in cortical bone increased by more than factor of 5 with the addition of mechanical loading.","abstract_html":"Quantitative research concerning the impact of mechanical loading on the transport properties of bone has several critical applications. One such application is the effect of a microgravity environment, where the lack of mechanical forces on bone has been shown to negatively impact both growth and repair. A method has been developed in our lab that can potentially allow for the measurement of the effective permeability of large molecules (i.e., 300-15,000 Da in size) in bone tissue under both unloaded and mechanically loaded conditions. In proof-of-concept experiments, previous students have measured the effective diffusivity of the model solute, sodium fluorescein (376 Da) in a sample of unloaded bone tissue. A mechanical loading system has been modified to measure the effective permeability of sodium fluorescein for a bone beam undergoing four point bend testing in a bioreactor system in order to quantify the effect of mechanical loading on solute transport. The first goal of the present work was to validate that deflection of the bone beam was occurring at applied displacements of less than 40 µm. Once the deflection of the bone beam in the mechanical loading system was validated, the primary objective of measuring the transport parameter for sodium fluorescein in canine cortical bone under unloaded and loaded conditions could be achieved. The average value and standard error of this parameter for loaded samples was determined to be 3.70x10&lt;sup&gt;-8&lt;/sup&gt;±1.31x10&lt;sup&gt;-8&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;s&lt;sup&gt;-1&lt;/sup&gt; (n=5), and 6.59x10&lt;sup&gt;-9&lt;/sup&gt;±2.46x10&lt;sup&gt;-9&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;s&lt;sup&gt;-1&lt;/sup&gt; (n=4) for unloaded samples. Although a student’s t-test showed that the loaded and unloaded values were not statistically different (p=0.08), this is likely due to the small number of samples. These preliminary results do show that the transport parameter of sodium fluorescein in cortical bone increased by more than factor of 5 with the addition of mechanical loading.","abstract_has_math":false,"creators":["Zak, Andrew Joseph"],"institution":"Cleveland State University","degree_name":"Master of Science in Chemical Engineering","degree_level":"masters","degree_discipline":"Washkewicz College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Belovich, Joanne"],"committee_members":[],"year":2015,"date_issued":"2015-12-09","date_published":"2015-12-09","updated_at":"2026-11-27T04:40:49Z","subjects":["Biomedical Engineering","Chemical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1449314893","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1449314893","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1449314893","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1449314893","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Belovich, Joanne"]},{"key":"dc:creator","label":"Author","values":["Zak, Andrew Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-12-09"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Washkewicz College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Chemical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1449314893"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Quantitative research concerning the impact of mechanical loading on the transport properties of bone has several critical applications. One such application is the effect of a microgravity environment, where the lack of mechanical forces on bone has been shown to negatively impact both growth and repair. A method has been developed in our lab that can potentially allow for the measurement of the effective permeability of large molecules (i.e., 300-15,000 Da in size) in bone tissue under both unloaded and mechanically loaded conditions. In proof-of-concept experiments, previous students have measured the effective diffusivity of the model solute, sodium fluorescein (376 Da) in a sample of unloaded bone tissue. A mechanical loading system has been modified to measure the effective permeability of sodium fluorescein for a bone beam undergoing four point bend testing in a bioreactor system in order to quantify the effect of mechanical loading on solute transport. The first goal of the present work was to validate that deflection of the bone beam was occurring at applied displacements of less than 40 µm. Once the deflection of the bone beam in the mechanical loading system was validated, the primary objective of measuring the transport parameter for sodium fluorescein in canine cortical bone under unloaded and loaded conditions could be achieved. The average value and standard error of this parameter for loaded samples was determined to be 3.70x10<sup>-8</sup>±1.31x10<sup>-8</sup> cm<sup>2</sup>s<sup>-1</sup> (n=5), and 6.59x10<sup>-9</sup>±2.46x10<sup>-9</sup> cm<sup>2</sup>s<sup>-1</sup> (n=4) for unloaded samples. Although a student’s t-test showed that the loaded and unloaded values were not statistically different (p=0.08), this is likely due to the small number of samples. These preliminary results do show that the transport parameter of sodium fluorescein in cortical bone increased by more than factor of 5 with the addition of mechanical loading."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","6.01 MB"]},{"key":"dc:title","label":"Title","values":["Determining the Transport Enhancement of Sodium Fluorescein in Mechanically-Loaded Canine Tibia"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Belovich, Joanne"],"dc:creator":["Zak, Andrew Joseph"],"dc:date":["2015-12-09"],"dc:description":["Quantitative research concerning the impact of mechanical loading on the transport properties of bone has several critical applications. One such application is the effect of a microgravity environment, where the lack of mechanical forces on bone has been shown to negatively impact both growth and repair. A method has been developed in our lab that can potentially allow for the measurement of the effective permeability of large molecules (i.e., 300-15,000 Da in size) in bone tissue under both unloaded and mechanically loaded conditions. In proof-of-concept experiments, previous students have measured the effective diffusivity of the model solute, sodium fluorescein (376 Da) in a sample of unloaded bone tissue. A mechanical loading system has been modified to measure the effective permeability of sodium fluorescein for a bone beam undergoing four point bend testing in a bioreactor system in order to quantify the effect of mechanical loading on solute transport. The first goal of the present work was to validate that deflection of the bone beam was occurring at applied displacements of less than 40 µm. Once the deflection of the bone beam in the mechanical loading system was validated, the primary objective of measuring the transport parameter for sodium fluorescein in canine cortical bone under unloaded and loaded conditions could be achieved. The average value and standard error of this parameter for loaded samples was determined to be 3.70x10<sup>-8</sup>±1.31x10<sup>-8</sup> cm<sup>2</sup>s<sup>-1</sup> (n=5), and 6.59x10<sup>-9</sup>±2.46x10<sup>-9</sup> cm<sup>2</sup>s<sup>-1</sup> (n=4) for unloaded samples. Although a student’s t-test showed that the loaded and unloaded values were not statistically different (p=0.08), this is likely due to the small number of samples. These preliminary results do show that the transport parameter of sodium fluorescein in cortical bone increased by more than factor of 5 with the addition of mechanical loading."],"dc:format":["application/pdf","6.01 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1449314893"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Chemical Engineering"],"dc:title":["Determining the Transport Enhancement of Sodium Fluorescein in Mechanically-Loaded Canine Tibia"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Washkewicz College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Chemical Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:40:49Z"}