{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1462375247"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1462375247","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Comparison of the Apple Watch, Fitbit Surge, and Actigraph GT9X Link in Measuring Energy Expenditure, Steps, Distance, and Heart Rate","abstract":"Introduction: Physical activity tracking devices have become a popular tool to help individuals become active and healthy. Purpose: The purpose of this study was to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph in estimating energy expenditure, steps, HR, and distance. Methods: An experimental study was used to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph to indirect calorimetry (energy expenditure), hand counting (steps), ScottCare Telemetry System (HR), and calibrated treadmill (distance). Twenty subjects (10 males, 10 females), wore the Apple Watch, Fitbit Surge and Actigraph while connected to the Cosmed and ScottCare system. Subjects jogged and walked two miles (on two separate testing days) while wearing all devices simultaneously. Energy expenditure, steps, HR, and distance were compared using Repeated Measures. If there was statistical significance, a protected T-Test was used to assess differences between devices. Results: During the two mile walk, both the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001); while the Apple Watch did not differ (p=0.238). For the two mile jog, the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001 and 0.008, respectively); while the Apple Watch did not differ (p=0.231). For steps during the walk and jog, there was no statistical difference between the hand counter and any of the three commercial devices. Compared to ScottCare HR, the Surge, Apple, and Actigraph did not significantly differ (p=0.916) for the walk. During the jog, the Surge and Actigraph did not significantly differ from ScottCare (p= 0.117 and 0.895 respectively), but the Apple watch did significantly differ (p=0 .0001). During the walk and run, the Fitbit significantly differed from the calibrated treadmill (p=0.0001), while the Apple Watch did not significantly differ (p=0.793 and 0.047, respectively). Conclusion: The results of this study support previous research that fitness devices are not always as accurate, but still give individuals a “ballpark” estimate of calories burned, steps, HR, and distance. Of the devices tested, the Apple Watch was generally the most accurate.","abstract_html":"Introduction: Physical activity tracking devices have become a popular tool to help individuals become active and healthy. Purpose: The purpose of this study was to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph in estimating energy expenditure, steps, HR, and distance. Methods: An experimental study was used to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph to indirect calorimetry (energy expenditure), hand counting (steps), ScottCare Telemetry System (HR), and calibrated treadmill (distance). Twenty subjects (10 males, 10 females), wore the Apple Watch, Fitbit Surge and Actigraph while connected to the Cosmed and ScottCare system. Subjects jogged and walked two miles (on two separate testing days) while wearing all devices simultaneously. Energy expenditure, steps, HR, and distance were compared using Repeated Measures. If there was statistical significance, a protected T-Test was used to assess differences between devices. Results: During the two mile walk, both the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001); while the Apple Watch did not differ (p=0.238). For the two mile jog, the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001 and 0.008, respectively); while the Apple Watch did not differ (p=0.231). For steps during the walk and jog, there was no statistical difference between the hand counter and any of the three commercial devices. Compared to ScottCare HR, the Surge, Apple, and Actigraph did not significantly differ (p=0.916) for the walk. During the jog, the Surge and Actigraph did not significantly differ from ScottCare (p= 0.117 and 0.895 respectively), but the Apple watch did significantly differ (p=0 .0001). During the walk and run, the Fitbit significantly differed from the calibrated treadmill (p=0.0001), while the Apple Watch did not significantly differ (p=0.793 and 0.047, respectively). Conclusion: The results of this study support previous research that fitness devices are not always as accurate, but still give individuals a “ballpark” estimate of calories burned, steps, HR, and distance. Of the devices tested, the Apple Watch was generally the most accurate.","abstract_has_math":false,"creators":["Kirk, Sarah E., Kirk"],"institution":"Cleveland State University","degree_name":"Master of Education","degree_level":"masters","degree_discipline":"College of Education and Human Services","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Sparks, Kenneth"],"committee_members":[],"year":2016,"date_issued":"2016-05-05","date_published":"2016-05-05","updated_at":"2026-11-27T04:41:05Z","subjects":["Health","Physical Education","Public Health","Sports Medicine","Fitbit Surge","Apple Watch","Actigraph GT9X","energy expenditure","steps","distance","heart rate","accuracy","physical activity tracking devices"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1462375247","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1462375247","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1462375247","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1462375247","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Sparks, Kenneth"]},{"key":"dc:creator","label":"Author","values":["Kirk, Sarah E., Kirk"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05-05"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Education and Human Services"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Education"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health","Physical Education","Public Health","Sports Medicine","Fitbit Surge","Apple Watch","Actigraph GT9X","energy expenditure","steps","distance","heart rate","accuracy","physical activity tracking devices"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1462375247"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Introduction: Physical activity tracking devices have become a popular tool to help individuals become active and healthy. Purpose: The purpose of this study was to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph in estimating energy expenditure, steps, HR, and distance. Methods: An experimental study was used to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph to indirect calorimetry (energy expenditure), hand counting (steps), ScottCare Telemetry System (HR), and calibrated treadmill (distance). Twenty subjects (10 males, 10 females), wore the Apple Watch, Fitbit Surge and Actigraph while connected to the Cosmed and ScottCare system. Subjects jogged and walked two miles (on two separate testing days) while wearing all devices simultaneously. Energy expenditure, steps, HR, and distance were compared using Repeated Measures. If there was statistical significance, a protected T-Test was used to assess differences between devices. Results: During the two mile walk, both the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001); while the Apple Watch did not differ (p=0.238). For the two mile jog, the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001 and 0.008, respectively); while the Apple Watch did not differ (p=0.231). For steps during the walk and jog, there was no statistical difference between the hand counter and any of the three commercial devices. Compared to ScottCare HR, the Surge, Apple, and Actigraph did not significantly differ (p=0.916) for the walk. During the jog, the Surge and Actigraph did not significantly differ from ScottCare (p= 0.117 and 0.895 respectively), but the Apple watch did significantly differ (p=0 .0001). During the walk and run, the Fitbit significantly differed from the calibrated treadmill (p=0.0001), while the Apple Watch did not significantly differ (p=0.793 and 0.047, respectively). Conclusion: The results of this study support previous research that fitness devices are not always as accurate, but still give individuals a “ballpark” estimate of calories burned, steps, HR, and distance. Of the devices tested, the Apple Watch was generally the most accurate."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.54","924. KB"]},{"key":"dc:title","label":"Title","values":["Comparison of the Apple Watch, Fitbit Surge, and Actigraph GT9X Link in Measuring Energy Expenditure, Steps, Distance, and Heart Rate"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Sparks, Kenneth"],"dc:creator":["Kirk, Sarah E., Kirk"],"dc:date":["2016-05-05"],"dc:description":["Introduction: Physical activity tracking devices have become a popular tool to help individuals become active and healthy. Purpose: The purpose of this study was to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph in estimating energy expenditure, steps, HR, and distance. Methods: An experimental study was used to compare the accuracy of the Apple Watch, Fitbit Surge, and Actigraph to indirect calorimetry (energy expenditure), hand counting (steps), ScottCare Telemetry System (HR), and calibrated treadmill (distance). Twenty subjects (10 males, 10 females), wore the Apple Watch, Fitbit Surge and Actigraph while connected to the Cosmed and ScottCare system. Subjects jogged and walked two miles (on two separate testing days) while wearing all devices simultaneously. Energy expenditure, steps, HR, and distance were compared using Repeated Measures. If there was statistical significance, a protected T-Test was used to assess differences between devices. Results: During the two mile walk, both the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001); while the Apple Watch did not differ (p=0.238). For the two mile jog, the Fitbit Surge and Actigraph significantly differed from the Cosmed (p=0.0001 and 0.008, respectively); while the Apple Watch did not differ (p=0.231). For steps during the walk and jog, there was no statistical difference between the hand counter and any of the three commercial devices. Compared to ScottCare HR, the Surge, Apple, and Actigraph did not significantly differ (p=0.916) for the walk. During the jog, the Surge and Actigraph did not significantly differ from ScottCare (p= 0.117 and 0.895 respectively), but the Apple watch did significantly differ (p=0 .0001). During the walk and run, the Fitbit significantly differed from the calibrated treadmill (p=0.0001), while the Apple Watch did not significantly differ (p=0.793 and 0.047, respectively). Conclusion: The results of this study support previous research that fitness devices are not always as accurate, but still give individuals a “ballpark” estimate of calories burned, steps, HR, and distance. Of the devices tested, the Apple Watch was generally the most accurate."],"dc:format":["application/pdf","p.54","924. KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1462375247"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health","Physical Education","Public Health","Sports Medicine","Fitbit Surge","Apple Watch","Actigraph GT9X","energy expenditure","steps","distance","heart rate","accuracy","physical activity tracking devices"],"dc:title":["Comparison of the Apple Watch, Fitbit Surge, and Actigraph GT9X Link in Measuring Energy Expenditure, Steps, Distance, and Heart Rate"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Education and Human Services"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Education"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:41:05Z"}