{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1462795576"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1462795576","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"HIGH CONTENT IMAGING ASSAYS ON MICROARRAY CHIP BASED PLATFORM","abstract":"Hepatotoxicity is a very common reason for drug withdrawal from the market. The conventional toxicology assessment models can lead to false negative and false positive outcomes due to lack of genetic relevance to humans (e.g., in vivo animal models) and poor cell-to-cell and cell-to-extracellular matrix (ECM) interactions (e.g., in vitro 2D cell models). Recent advances in “bioprinting” technology open up new possibilities for rapid and more reliable human cell-based toxicity assays. The present study aims at mechanistic toxicity assessment by using the Hep3B human hepatoma cell line encapsulated in two different hydrogel formulations via bioprinting on a micropillar/microwell chip platform and conducting high-content imaging (HCI) assays. The Hep3B cells grown into spheroids were exposed to six model compounds that are known to cause hepatotoxicity through different mechanisms, including mitochondrial dysfunction, DNA impairment, oxidative stress, and apoptosis/necrosis. The automated bioprinting technique we optimized on the chip platform provided robust data from HCI assays, with low coefficient of variation (CV) from the chips. The twenty four different dose response curves and IC50 values were obtained from the four different endpoints with the six compounds, and the results were compared with the previously published data. Altogether, the present study demonstrates that the Hep3B cells cultured in 3D on the chip platform can be used for rapid screening of compounds for their mechanistic hepatotoxicity via HCI assays.","abstract_html":"Hepatotoxicity is a very common reason for drug withdrawal from the market. The conventional toxicology assessment models can lead to false negative and false positive outcomes due to lack of genetic relevance to humans (e.g., in vivo animal models) and poor cell-to-cell and cell-to-extracellular matrix (ECM) interactions (e.g., in vitro 2D cell models). Recent advances in “bioprinting” technology open up new possibilities for rapid and more reliable human cell-based toxicity assays. The present study aims at mechanistic toxicity assessment by using the Hep3B human hepatoma cell line encapsulated in two different hydrogel formulations via bioprinting on a micropillar/microwell chip platform and conducting high-content imaging (HCI) assays. The Hep3B cells grown into spheroids were exposed to six model compounds that are known to cause hepatotoxicity through different mechanisms, including mitochondrial dysfunction, DNA impairment, oxidative stress, and apoptosis/necrosis. The automated bioprinting technique we optimized on the chip platform provided robust data from HCI assays, with low coefficient of variation (CV) from the chips. The twenty four different dose response curves and IC50 values were obtained from the four different endpoints with the six compounds, and the results were compared with the previously published data. Altogether, the present study demonstrates that the Hep3B cells cultured in 3D on the chip platform can be used for rapid screening of compounds for their mechanistic hepatotoxicity via HCI assays.","abstract_has_math":false,"creators":["Datar, Akshata"],"institution":"Cleveland State University","degree_name":"Master of Science in Biomedical Engineering","degree_level":"masters","degree_discipline":"Washkewicz College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Lee, Moo-Yeal"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05-13","date_published":"2016-05-13","updated_at":"2026-11-27T04:41:05Z","subjects":["Biomedical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1462795576","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1462795576","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1462795576","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1462795576","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lee, Moo-Yeal"]},{"key":"dc:creator","label":"Author","values":["Datar, Akshata"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05-13"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Washkewicz College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1462795576"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Hepatotoxicity is a very common reason for drug withdrawal from the market. The conventional toxicology assessment models can lead to false negative and false positive outcomes due to lack of genetic relevance to humans (e.g., in vivo animal models) and poor cell-to-cell and cell-to-extracellular matrix (ECM) interactions (e.g., in vitro 2D cell models). Recent advances in “bioprinting” technology open up new possibilities for rapid and more reliable human cell-based toxicity assays. The present study aims at mechanistic toxicity assessment by using the Hep3B human hepatoma cell line encapsulated in two different hydrogel formulations via bioprinting on a micropillar/microwell chip platform and conducting high-content imaging (HCI) assays. The Hep3B cells grown into spheroids were exposed to six model compounds that are known to cause hepatotoxicity through different mechanisms, including mitochondrial dysfunction, DNA impairment, oxidative stress, and apoptosis/necrosis. The automated bioprinting technique we optimized on the chip platform provided robust data from HCI assays, with low coefficient of variation (CV) from the chips. The twenty four different dose response curves and IC50 values were obtained from the four different endpoints with the six compounds, and the results were compared with the previously published data. Altogether, the present study demonstrates that the Hep3B cells cultured in 3D on the chip platform can be used for rapid screening of compounds for their mechanistic hepatotoxicity via HCI assays."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.105","16.08 MB"]},{"key":"dc:title","label":"Title","values":["HIGH CONTENT IMAGING ASSAYS ON MICROARRAY CHIP BASED PLATFORM"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lee, Moo-Yeal"],"dc:creator":["Datar, Akshata"],"dc:date":["2016-05-13"],"dc:description":["Hepatotoxicity is a very common reason for drug withdrawal from the market. The conventional toxicology assessment models can lead to false negative and false positive outcomes due to lack of genetic relevance to humans (e.g., in vivo animal models) and poor cell-to-cell and cell-to-extracellular matrix (ECM) interactions (e.g., in vitro 2D cell models). Recent advances in “bioprinting” technology open up new possibilities for rapid and more reliable human cell-based toxicity assays. The present study aims at mechanistic toxicity assessment by using the Hep3B human hepatoma cell line encapsulated in two different hydrogel formulations via bioprinting on a micropillar/microwell chip platform and conducting high-content imaging (HCI) assays. The Hep3B cells grown into spheroids were exposed to six model compounds that are known to cause hepatotoxicity through different mechanisms, including mitochondrial dysfunction, DNA impairment, oxidative stress, and apoptosis/necrosis. The automated bioprinting technique we optimized on the chip platform provided robust data from HCI assays, with low coefficient of variation (CV) from the chips. The twenty four different dose response curves and IC50 values were obtained from the four different endpoints with the six compounds, and the results were compared with the previously published data. Altogether, the present study demonstrates that the Hep3B cells cultured in 3D on the chip platform can be used for rapid screening of compounds for their mechanistic hepatotoxicity via HCI assays."],"dc:format":["application/pdf","p.105","16.08 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1462795576"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering"],"dc:title":["HIGH CONTENT IMAGING ASSAYS ON MICROARRAY CHIP BASED PLATFORM"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Washkewicz College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:41:05Z"}