{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:kent1256325512"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:kent1256325512","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"OXYBUOY: CONSTRUCTING A REAL-TIME INEXPENSIVE HYPOXIA MONITORING PLATFORM","abstract":"Hypoxia is a world-wide anthropogenic phenomenon related to pollution. Hypoxia is poorly understood and requires extensive observations. We describe the construction of an inexpensive sensor buoy system, Oxybuoy, designed for long-term unattended oxygen sensor measurements. The technology is available to construct such sensor buoys. However, the market niche is too narrow to justify specialized sensor development by commercial companies. The available equipment is either too expensive or not adequate. We propose to use commercial off-the shelf components: an embedded PC, an optical dissolved oxygen sensor, a temperature sensor, a WiFi transmitter and a satellite transmitter. It’s total cost is around $5,000 to construct, program and test a proof of concept of such sensor. We describe the buoy’s architectural design and three experiments that we carried out to demonstrate its viability: a laboratory test in a water tank with controlled oxygen level, a lake deployment and an extensive electric power consumption test. Our experiments indicate the viability of such an approach to dissolved oxygen monitoring and promise further advances in hypoxia studies.","abstract_html":"Hypoxia is a world-wide anthropogenic phenomenon related to pollution. Hypoxia is poorly understood and requires extensive observations. We describe the construction of an inexpensive sensor buoy system, Oxybuoy, designed for long-term unattended oxygen sensor measurements. The technology is available to construct such sensor buoys. However, the market niche is too narrow to justify specialized sensor development by commercial companies. The available equipment is either too expensive or not adequate. We propose to use commercial off-the shelf components: an embedded PC, an optical dissolved oxygen sensor, a temperature sensor, a WiFi transmitter and a satellite transmitter. It’s total cost is around $5,000 to construct, program and test a proof of concept of such sensor. We describe the buoy’s architectural design and three experiments that we carried out to demonstrate its viability: a laboratory test in a water tank with controlled oxygen level, a lake deployment and an extensive electric power consumption test. Our experiments indicate the viability of such an approach to dissolved oxygen monitoring and promise further advances in hypoxia studies.","abstract_has_math":false,"creators":["MOHD NOR, RIZAL"],"institution":"Kent State University","degree_name":"MS","degree_level":"masters","degree_discipline":"College of Arts and Sciences / Department of Computer Science","degree_department":null,"school":null,"contributors":[],"advisors":["Nesterenko, Mikhail"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-10-27","date_published":"2009-10-27","updated_at":"2026-11-27T04:15:18Z","subjects":["Computer Science","Sensor Networks","Hypoxia","Embedded Devices","Satellite Communication","Optical Dissolved Oxygen Sensor"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=kent1256325512","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=kent1256325512","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Akent1256325512","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Akent1256325512","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Nesterenko, Mikhail"]},{"key":"dc:creator","label":"Author","values":["MOHD NOR, RIZAL"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-10-27"]},{"key":"dc:publisher","label":"Institution","values":["Kent State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Arts and Sciences / Department of Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Kent State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Science","Sensor Networks","Hypoxia","Embedded Devices","Satellite Communication","Optical Dissolved Oxygen Sensor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=kent1256325512"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Hypoxia is a world-wide anthropogenic phenomenon related to pollution. Hypoxia is poorly understood and requires extensive observations. We describe the construction of an inexpensive sensor buoy system, Oxybuoy, designed for long-term unattended oxygen sensor measurements. The technology is available to construct such sensor buoys. However, the market niche is too narrow to justify specialized sensor development by commercial companies. The available equipment is either too expensive or not adequate. We propose to use commercial off-the shelf components: an embedded PC, an optical dissolved oxygen sensor, a temperature sensor, a WiFi transmitter and a satellite transmitter. It’s total cost is around $5,000 to construct, program and test a proof of concept of such sensor. We describe the buoy’s architectural design and three experiments that we carried out to demonstrate its viability: a laboratory test in a water tank with controlled oxygen level, a lake deployment and an extensive electric power consumption test. Our experiments indicate the viability of such an approach to dissolved oxygen monitoring and promise further advances in hypoxia studies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.34","770.3 KB"]},{"key":"dc:title","label":"Title","values":["OXYBUOY: CONSTRUCTING A REAL-TIME INEXPENSIVE HYPOXIA MONITORING PLATFORM"]}]}],"canonical_facts":{"dc:contributor.advisor":["Nesterenko, Mikhail"],"dc:creator":["MOHD NOR, RIZAL"],"dc:date":["2009-10-27"],"dc:description":["Hypoxia is a world-wide anthropogenic phenomenon related to pollution. Hypoxia is poorly understood and requires extensive observations. We describe the construction of an inexpensive sensor buoy system, Oxybuoy, designed for long-term unattended oxygen sensor measurements. The technology is available to construct such sensor buoys. However, the market niche is too narrow to justify specialized sensor development by commercial companies. The available equipment is either too expensive or not adequate. We propose to use commercial off-the shelf components: an embedded PC, an optical dissolved oxygen sensor, a temperature sensor, a WiFi transmitter and a satellite transmitter. It’s total cost is around $5,000 to construct, program and test a proof of concept of such sensor. We describe the buoy’s architectural design and three experiments that we carried out to demonstrate its viability: a laboratory test in a water tank with controlled oxygen level, a lake deployment and an extensive electric power consumption test. Our experiments indicate the viability of such an approach to dissolved oxygen monitoring and promise further advances in hypoxia studies."],"dc:format":["application/pdf","p.34","770.3 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=kent1256325512"],"dc:language":["English"],"dc:publisher":["Kent State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Computer Science","Sensor Networks","Hypoxia","Embedded Devices","Satellite Communication","Optical Dissolved Oxygen Sensor"],"dc:title":["OXYBUOY: CONSTRUCTING A REAL-TIME INEXPENSIVE HYPOXIA MONITORING PLATFORM"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Arts and Sciences / Department of Computer Science"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["Kent State University"]},"updated_at":"2026-11-27T04:15:18Z"}