{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1115061845"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1115061845","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Assessment of Cervical Spine Morphology by Computed Tomography and its Utility as a Presurgical Planning Tool","abstract":"Cadaver cervical spine specimens from the Medical College of Ohio Anatomy Department were scanned using various protocols on two separate CT scanners. The slice thickness, technique parameters and image algorithms were varied and compared. The CT measurements were compared to actual physical measurements from the specimens and correlated. The study concluded that CT is useful for evaluation of osseous structures in the cervical spine and adequately demonstrate the relationship to essential neurovascular structures. Partial volume averaging is a considerable problem in sectional imaging. This study found that a smaller slice thickness minimized the partial volume averaging, minimized the overestimation of size of small structures, such as the pedicle, and provided a more accurate pre-surgical assessment. The choice of image algorithm for pre-surgical planning of the cervical spine is the bone algorithm. The standard or soft tissue algorithm results in overestimation of size. A simple theoretical calculation of CT numbers to determine percent bone in voxel necessary for the voxel to be identified as bone show 20% bone will identify the voxel as bone at 60, 80 and 100 keV.","abstract_html":"Cadaver cervical spine specimens from the Medical College of Ohio Anatomy Department were scanned using various protocols on two separate CT scanners. The slice thickness, technique parameters and image algorithms were varied and compared. The CT measurements were compared to actual physical measurements from the specimens and correlated. The study concluded that CT is useful for evaluation of osseous structures in the cervical spine and adequately demonstrate the relationship to essential neurovascular structures. Partial volume averaging is a considerable problem in sectional imaging. This study found that a smaller slice thickness minimized the partial volume averaging, minimized the overestimation of size of small structures, such as the pedicle, and provided a more accurate pre-surgical assessment. The choice of image algorithm for pre-surgical planning of the cervical spine is the bone algorithm. The standard or soft tissue algorithm results in overestimation of size. A simple theoretical calculation of CT numbers to determine percent bone in voxel necessary for the voxel to be identified as bone show 20% bone will identify the voxel as bone at 60, 80 and 100 keV.","abstract_has_math":false,"creators":["Martensen, Jan"],"institution":"University of Toledo Health Science Campus","degree_name":"Doctor of Philosophy in Medical Sciences (Ph.D.)","degree_level":"doctoral","degree_discipline":"Graduate School","degree_department":null,"school":null,"contributors":[],"advisors":["Dennis, Ph.D., Michael"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-11-27T04:17:19Z","subjects":["Health Sciences, Radiology","spine","anatomic morphology","image processing","pre-surgical evaluation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1115061845","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1115061845","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1115061845","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1115061845","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dennis, Ph.D., Michael"]},{"key":"dc:creator","label":"Author","values":["Martensen, Jan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Graduate School"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy in Medical Sciences (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Sciences, Radiology","spine","anatomic morphology","image processing","pre-surgical evaluation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1115061845"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Cadaver cervical spine specimens from the Medical College of Ohio Anatomy Department were scanned using various protocols on two separate CT scanners. The slice thickness, technique parameters and image algorithms were varied and compared. The CT measurements were compared to actual physical measurements from the specimens and correlated. The study concluded that CT is useful for evaluation of osseous structures in the cervical spine and adequately demonstrate the relationship to essential neurovascular structures. Partial volume averaging is a considerable problem in sectional imaging. This study found that a smaller slice thickness minimized the partial volume averaging, minimized the overestimation of size of small structures, such as the pedicle, and provided a more accurate pre-surgical assessment. The choice of image algorithm for pre-surgical planning of the cervical spine is the bone algorithm. The standard or soft tissue algorithm results in overestimation of size. A simple theoretical calculation of CT numbers to determine percent bone in voxel necessary for the voxel to be identified as bone show 20% bone will identify the voxel as bone at 60, 80 and 100 keV."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.169","4.8 MB"]},{"key":"dc:title","label":"Title","values":["Assessment of Cervical Spine Morphology by Computed Tomography and its Utility as a Presurgical Planning Tool"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dennis, Ph.D., Michael"],"dc:creator":["Martensen, Jan"],"dc:date":["2004"],"dc:description":["Cadaver cervical spine specimens from the Medical College of Ohio Anatomy Department were scanned using various protocols on two separate CT scanners. The slice thickness, technique parameters and image algorithms were varied and compared. The CT measurements were compared to actual physical measurements from the specimens and correlated. The study concluded that CT is useful for evaluation of osseous structures in the cervical spine and adequately demonstrate the relationship to essential neurovascular structures. Partial volume averaging is a considerable problem in sectional imaging. This study found that a smaller slice thickness minimized the partial volume averaging, minimized the overestimation of size of small structures, such as the pedicle, and provided a more accurate pre-surgical assessment. The choice of image algorithm for pre-surgical planning of the cervical spine is the bone algorithm. The standard or soft tissue algorithm results in overestimation of size. A simple theoretical calculation of CT numbers to determine percent bone in voxel necessary for the voxel to be identified as bone show 20% bone will identify the voxel as bone at 60, 80 and 100 keV."],"dc:format":["application/pdf","p.169","4.8 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1115061845"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health Sciences, Radiology","spine","anatomic morphology","image processing","pre-surgical evaluation"],"dc:title":["Assessment of Cervical Spine Morphology by Computed Tomography and its Utility as a Presurgical Planning Tool"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Graduate School"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy in Medical Sciences (Ph.D.)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}