{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1140102086"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1140102086","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Positron Emission Tomography (PET)System Comparison Utilizing the American College of Radiology Accreditation Phantom","abstract":"This work utilizes the American College of Radiology (ACR) Positron Emission Tomography (PET) Accreditation Phantom to compare and contrast PET systems utilizing the ACR’s testing procedure and evaluation parameters. The ACR PET accreditation test instructions are re-written with step-by-step instructions to facilitate performance of either the “long” or “short” version of the test procedure. Possible errors encountered while completing over sixteen ACR PET accreditation tests during a 14- month span are presented along with the specific results of these tests. Each camera model was tested twice at different PET imaging facilities to reduce site specific variations Analysis of the measurements indicated that the types of transmission sources appeared to matter less than the transmission source activity; the newer scintillation materials with faster response, GSO and LSO, appear to outperform the BGO and NaI systems; and the full-ring systems outperformed the split-ring systems overall.","abstract_html":"This work utilizes the American College of Radiology (ACR) Positron Emission Tomography (PET) Accreditation Phantom to compare and contrast PET systems utilizing the ACR’s testing procedure and evaluation parameters. The ACR PET accreditation test instructions are re-written with step-by-step instructions to facilitate performance of either the “long” or “short” version of the test procedure. Possible errors encountered while completing over sixteen ACR PET accreditation tests during a 14- month span are presented along with the specific results of these tests. Each camera model was tested twice at different PET imaging facilities to reduce site specific variations Analysis of the measurements indicated that the types of transmission sources appeared to matter less than the transmission source activity; the newer scintillation materials with faster response, GSO and LSO, appear to outperform the BGO and NaI systems; and the full-ring systems outperformed the split-ring systems overall.","abstract_has_math":false,"creators":["Borrelli, Leonard M."],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Biomedical Sciences (MSBS)","degree_level":"masters","degree_discipline":"College of Graduate Studies","degree_department":null,"school":null,"contributors":[],"advisors":["Dennis, Ph.D., Michael"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-27T04:17:19Z","subjects":["Health Sciences, Radiology","PET","Positron Emission Tomography","Accreditation Testing"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1140102086","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1140102086","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1140102086","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1140102086","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dennis, Ph.D., Michael"]},{"key":"dc:creator","label":"Author","values":["Borrelli, Leonard M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Graduate Studies"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Sciences (MSBS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Sciences, Radiology","PET","Positron Emission Tomography","Accreditation Testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1140102086"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This work utilizes the American College of Radiology (ACR) Positron Emission Tomography (PET) Accreditation Phantom to compare and contrast PET systems utilizing the ACR’s testing procedure and evaluation parameters. The ACR PET accreditation test instructions are re-written with step-by-step instructions to facilitate performance of either the “long” or “short” version of the test procedure. Possible errors encountered while completing over sixteen ACR PET accreditation tests during a 14- month span are presented along with the specific results of these tests. Each camera model was tested twice at different PET imaging facilities to reduce site specific variations Analysis of the measurements indicated that the types of transmission sources appeared to matter less than the transmission source activity; the newer scintillation materials with faster response, GSO and LSO, appear to outperform the BGO and NaI systems; and the full-ring systems outperformed the split-ring systems overall."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.82","2.56 MB"]},{"key":"dc:title","label":"Title","values":["A Positron Emission Tomography (PET)System Comparison Utilizing the American College of Radiology Accreditation Phantom"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dennis, Ph.D., Michael"],"dc:creator":["Borrelli, Leonard M."],"dc:date":["2005"],"dc:description":["This work utilizes the American College of Radiology (ACR) Positron Emission Tomography (PET) Accreditation Phantom to compare and contrast PET systems utilizing the ACR’s testing procedure and evaluation parameters. The ACR PET accreditation test instructions are re-written with step-by-step instructions to facilitate performance of either the “long” or “short” version of the test procedure. Possible errors encountered while completing over sixteen ACR PET accreditation tests during a 14- month span are presented along with the specific results of these tests. Each camera model was tested twice at different PET imaging facilities to reduce site specific variations Analysis of the measurements indicated that the types of transmission sources appeared to matter less than the transmission source activity; the newer scintillation materials with faster response, GSO and LSO, appear to outperform the BGO and NaI systems; and the full-ring systems outperformed the split-ring systems overall."],"dc:format":["application/pdf","p.82","2.56 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1140102086"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health Sciences, Radiology","PET","Positron Emission Tomography","Accreditation Testing"],"dc:title":["A Positron Emission Tomography (PET)System Comparison Utilizing the American College of Radiology Accreditation Phantom"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Graduate Studies"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Sciences (MSBS)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}