{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1147298726"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1147298726","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation","abstract":"Moderated gold foil activation was used to measure the neutron fluence from the Siemens Oncor linear accelerator. Measurements were made both in the photon beam and in peripheral locations using 20x20cm jaw settings. The head leakage was measured as well, with the jaws closed as is prescribed in AAPM report 19. The neutron fluence values then were used to calculate source strength (Q) along with the respective equivalent doses. The neutron fluence from the 20cm x 20cm field resulted in a Q value of 0.33 x1012 n/Gy. The peripheral dose equivalent was found to be 0.27 mSv/Gy at a 100cm radius from isocenter. The in-beam neutrons delivered a dose of 0.958 mGy/Gy. The total neutron leakage through the head was 2.8 x106 n/cm2/Gy, measured at 28cm out from the isocenter. It was found that the neutron production did not pose any risk greater than other machines currently available.","abstract_html":"Moderated gold foil activation was used to measure the neutron fluence from the Siemens Oncor linear accelerator. Measurements were made both in the photon beam and in peripheral locations using 20x20cm jaw settings. The head leakage was measured as well, with the jaws closed as is prescribed in AAPM report 19. The neutron fluence values then were used to calculate source strength (Q) along with the respective equivalent doses. The neutron fluence from the 20cm x 20cm field resulted in a Q value of 0.33 x1012 n/Gy. The peripheral dose equivalent was found to be 0.27 mSv/Gy at a 100cm radius from isocenter. The in-beam neutrons delivered a dose of 0.958 mGy/Gy. The total neutron leakage through the head was 2.8 x106 n/cm2/Gy, measured at 28cm out from the isocenter. It was found that the neutron production did not pose any risk greater than other machines currently available.","abstract_has_math":false,"creators":["Hill, Todd Michael"],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Biomedical Sciences (MSBS)","degree_level":"masters","degree_discipline":"College of Graduate Studies","degree_department":null,"school":null,"contributors":[],"advisors":["Parsai, Ph.D., E. Ishmael"],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-05-10","date_published":"2006-05-10","updated_at":"2026-11-27T04:17:19Z","subjects":["Neutron Measurement","Gold Foil Activation","Seimens Primus","Siemens Oncor"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1147298726","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1147298726","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1147298726","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1147298726","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parsai, Ph.D., E. Ishmael"]},{"key":"dc:creator","label":"Author","values":["Hill, Todd Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-05-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Graduate Studies"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Sciences (MSBS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neutron Measurement","Gold Foil Activation","Seimens Primus","Siemens Oncor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1147298726"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Moderated gold foil activation was used to measure the neutron fluence from the Siemens Oncor linear accelerator. Measurements were made both in the photon beam and in peripheral locations using 20x20cm jaw settings. The head leakage was measured as well, with the jaws closed as is prescribed in AAPM report 19. The neutron fluence values then were used to calculate source strength (Q) along with the respective equivalent doses. The neutron fluence from the 20cm x 20cm field resulted in a Q value of 0.33 x1012 n/Gy. The peripheral dose equivalent was found to be 0.27 mSv/Gy at a 100cm radius from isocenter. The in-beam neutrons delivered a dose of 0.958 mGy/Gy. The total neutron leakage through the head was 2.8 x106 n/cm2/Gy, measured at 28cm out from the isocenter. It was found that the neutron production did not pose any risk greater than other machines currently available."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.43","967.1 KB"]},{"key":"dc:title","label":"Title","values":["Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parsai, Ph.D., E. Ishmael"],"dc:creator":["Hill, Todd Michael"],"dc:date":["2006-05-10"],"dc:description":["Moderated gold foil activation was used to measure the neutron fluence from the Siemens Oncor linear accelerator. Measurements were made both in the photon beam and in peripheral locations using 20x20cm jaw settings. The head leakage was measured as well, with the jaws closed as is prescribed in AAPM report 19. The neutron fluence values then were used to calculate source strength (Q) along with the respective equivalent doses. The neutron fluence from the 20cm x 20cm field resulted in a Q value of 0.33 x1012 n/Gy. The peripheral dose equivalent was found to be 0.27 mSv/Gy at a 100cm radius from isocenter. The in-beam neutrons delivered a dose of 0.958 mGy/Gy. The total neutron leakage through the head was 2.8 x106 n/cm2/Gy, measured at 28cm out from the isocenter. It was found that the neutron production did not pose any risk greater than other machines currently available."],"dc:format":["application/pdf","p.43","967.1 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1147298726"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Neutron Measurement","Gold Foil Activation","Seimens Primus","Siemens Oncor"],"dc:title":["Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Graduate Studies"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Sciences (MSBS)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}