{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1188924969"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1188924969","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Design and Set Up of a System for Testing HEPA Filter Efficiency","abstract":"High efficiency particulate air (HEPA) filters by definition have an air particle removal efficiency of ≥ 99.97%. Installation of a HEPA filter, however, introduces variables that can compromise the filter’s efficiency. The main objective of this research project was to set up a “filter testing unit” to evaluate HEPA filter efficiency in relation to specific filter handling and installation variables. A closed system “HEPA filter testing unit” was assembled consisting of a fan, industrial damper, two ducts, and filter housing. The concentrations of a challenge aerosol up-stream and down-stream were used to calculate the filters capture efficiency. Eight filters were evaluated based on filter characteristics, particle capture efficiency, and consistency of proper installation. The results of this study indicated that any damage to the filter or flaw in the handling and installation process can compromise the performance of the HEPA filter significantly.","abstract_html":"High efficiency particulate air (HEPA) filters by definition have an air particle removal efficiency of ≥ 99.97%. Installation of a HEPA filter, however, introduces variables that can compromise the filter’s efficiency. The main objective of this research project was to set up a “filter testing unit” to evaluate HEPA filter efficiency in relation to specific filter handling and installation variables. A closed system “HEPA filter testing unit” was assembled consisting of a fan, industrial damper, two ducts, and filter housing. The concentrations of a challenge aerosol up-stream and down-stream were used to calculate the filters capture efficiency. Eight filters were evaluated based on filter characteristics, particle capture efficiency, and consistency of proper installation. The results of this study indicated that any damage to the filter or flaw in the handling and installation process can compromise the performance of the HEPA filter significantly.","abstract_has_math":false,"creators":["Smigielski, Ken Alan"],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Occupational Health (MSOH)","degree_level":"masters","degree_discipline":"College of Graduate Studies","degree_department":null,"school":null,"contributors":[],"advisors":["Akbar, Farhang"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-09-25","date_published":"2007-09-25","updated_at":"2026-11-27T04:17:19Z","subjects":["HEPA","Filter","Efficiency"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1188924969","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1188924969","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1188924969","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1188924969","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Akbar, Farhang"]},{"key":"dc:creator","label":"Author","values":["Smigielski, Ken Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-09-25"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Graduate Studies"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Occupational Health (MSOH)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["HEPA","Filter","Efficiency"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1188924969"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["High efficiency particulate air (HEPA) filters by definition have an air particle removal efficiency of ≥ 99.97%. Installation of a HEPA filter, however, introduces variables that can compromise the filter’s efficiency. The main objective of this research project was to set up a “filter testing unit” to evaluate HEPA filter efficiency in relation to specific filter handling and installation variables. A closed system “HEPA filter testing unit” was assembled consisting of a fan, industrial damper, two ducts, and filter housing. The concentrations of a challenge aerosol up-stream and down-stream were used to calculate the filters capture efficiency. Eight filters were evaluated based on filter characteristics, particle capture efficiency, and consistency of proper installation. The results of this study indicated that any damage to the filter or flaw in the handling and installation process can compromise the performance of the HEPA filter significantly."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.37","558.9 KB"]},{"key":"dc:title","label":"Title","values":["Design and Set Up of a System for Testing HEPA Filter Efficiency"]}]}],"canonical_facts":{"dc:contributor.advisor":["Akbar, Farhang"],"dc:creator":["Smigielski, Ken Alan"],"dc:date":["2007-09-25"],"dc:description":["High efficiency particulate air (HEPA) filters by definition have an air particle removal efficiency of ≥ 99.97%. Installation of a HEPA filter, however, introduces variables that can compromise the filter’s efficiency. The main objective of this research project was to set up a “filter testing unit” to evaluate HEPA filter efficiency in relation to specific filter handling and installation variables. A closed system “HEPA filter testing unit” was assembled consisting of a fan, industrial damper, two ducts, and filter housing. The concentrations of a challenge aerosol up-stream and down-stream were used to calculate the filters capture efficiency. Eight filters were evaluated based on filter characteristics, particle capture efficiency, and consistency of proper installation. The results of this study indicated that any damage to the filter or flaw in the handling and installation process can compromise the performance of the HEPA filter significantly."],"dc:format":["application/pdf","p.37","558.9 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1188924969"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["HEPA","Filter","Efficiency"],"dc:title":["Design and Set Up of a System for Testing HEPA Filter Efficiency"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Graduate Studies"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Occupational Health (MSOH)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}