{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1211995092"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1211995092","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Solar Ultraviolet Radiation Exposure in Outdoor Work Environment at Bowling Green, Ohio","abstract":"Outdoor workers are routinely unprotected from solar UVR, which can result in healtheffects. Approximately 5 ft from the ground Actinic (effective) were measured within anopen field at Bowling Green, Ohio. Measurements occurred on 10 days during theperiod of October - December, 2007. UVR levels were determined for the directions ofup (0.601), down-asphalt (0.121 μW/cm2), down-grass (0.078 μW/cm2), down-snow(0.396 μW/cm2), north (0.243 μW/cm2), south (0.767 μW/cm2), east (0.362 μW/cm2),west (0.332 μW/cm2), and toward the sun (0.935 μW/cm2). When the sun is 100% or upto 75% cloud-free, one can predict the UVR irradiance exposures and maximumallowable exposure times (MAETs). When the sun is < 75% cloud-free, one can nolonger make accurate predictions according to statistical analysis used in this study.This research indicates that outdoor workers are exposed to solar UVR at or above theACGIH (2008) criteria during their 8-hr workshift, which means that the hazard needs tobe controlled to protect workers; this may be done by wearing protective clothing,reducing the exposure time or applying other appropriate control methods.","abstract_html":"Outdoor workers are routinely unprotected from solar UVR, which can result in healtheffects. Approximately 5 ft from the ground Actinic (effective) were measured within anopen field at Bowling Green, Ohio. Measurements occurred on 10 days during theperiod of October - December, 2007. UVR levels were determined for the directions ofup (0.601), down-asphalt (0.121 μW/cm2), down-grass (0.078 μW/cm2), down-snow(0.396 μW/cm2), north (0.243 μW/cm2), south (0.767 μW/cm2), east (0.362 μW/cm2),west (0.332 μW/cm2), and toward the sun (0.935 μW/cm2). When the sun is 100% or upto 75% cloud-free, one can predict the UVR irradiance exposures and maximumallowable exposure times (MAETs). When the sun is &lt; 75% cloud-free, one can nolonger make accurate predictions according to statistical analysis used in this study.This research indicates that outdoor workers are exposed to solar UVR at or above theACGIH (2008) criteria during their 8-hr workshift, which means that the hazard needs tobe controlled to protect workers; this may be done by wearing protective clothing,reducing the exposure time or applying other appropriate control methods.","abstract_has_math":false,"creators":["Weaver, Bess A."],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Occupational Health (MSOH)","degree_level":"masters","degree_discipline":"College of Graduate Studies","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Akbar-Khanzadeh, Farhang"],"committee_members":[],"year":2008,"date_issued":"2008-06-18","date_published":"2008-06-18","updated_at":"2026-11-27T04:17:19Z","subjects":["Occupational Safety","Radiation","solar ultraviolet radiation","sun exposure","solar UVR"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1211995092","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1211995092","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1211995092","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1211995092","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Akbar-Khanzadeh, Farhang"]},{"key":"dc:creator","label":"Author","values":["Weaver, Bess A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-06-18"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Graduate Studies"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Occupational Health (MSOH)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Occupational Safety","Radiation","solar ultraviolet radiation","sun exposure","solar UVR"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1211995092"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Outdoor workers are routinely unprotected from solar UVR, which can result in healtheffects. Approximately 5 ft from the ground Actinic (effective) were measured within anopen field at Bowling Green, Ohio. Measurements occurred on 10 days during theperiod of October - December, 2007. UVR levels were determined for the directions ofup (0.601), down-asphalt (0.121 μW/cm2), down-grass (0.078 μW/cm2), down-snow(0.396 μW/cm2), north (0.243 μW/cm2), south (0.767 μW/cm2), east (0.362 μW/cm2),west (0.332 μW/cm2), and toward the sun (0.935 μW/cm2). When the sun is 100% or upto 75% cloud-free, one can predict the UVR irradiance exposures and maximumallowable exposure times (MAETs). When the sun is < 75% cloud-free, one can nolonger make accurate predictions according to statistical analysis used in this study.This research indicates that outdoor workers are exposed to solar UVR at or above theACGIH (2008) criteria during their 8-hr workshift, which means that the hazard needs tobe controlled to protect workers; this may be done by wearing protective clothing,reducing the exposure time or applying other appropriate control methods."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.86","387.9 KB"]},{"key":"dc:title","label":"Title","values":["Solar Ultraviolet Radiation Exposure in Outdoor Work Environment at Bowling Green, Ohio"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Akbar-Khanzadeh, Farhang"],"dc:creator":["Weaver, Bess A."],"dc:date":["2008-06-18"],"dc:description":["Outdoor workers are routinely unprotected from solar UVR, which can result in healtheffects. Approximately 5 ft from the ground Actinic (effective) were measured within anopen field at Bowling Green, Ohio. Measurements occurred on 10 days during theperiod of October - December, 2007. UVR levels were determined for the directions ofup (0.601), down-asphalt (0.121 μW/cm2), down-grass (0.078 μW/cm2), down-snow(0.396 μW/cm2), north (0.243 μW/cm2), south (0.767 μW/cm2), east (0.362 μW/cm2),west (0.332 μW/cm2), and toward the sun (0.935 μW/cm2). When the sun is 100% or upto 75% cloud-free, one can predict the UVR irradiance exposures and maximumallowable exposure times (MAETs). When the sun is < 75% cloud-free, one can nolonger make accurate predictions according to statistical analysis used in this study.This research indicates that outdoor workers are exposed to solar UVR at or above theACGIH (2008) criteria during their 8-hr workshift, which means that the hazard needs tobe controlled to protect workers; this may be done by wearing protective clothing,reducing the exposure time or applying other appropriate control methods."],"dc:format":["application/pdf","p.86","387.9 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1211995092"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Occupational Safety","Radiation","solar ultraviolet radiation","sun exposure","solar UVR"],"dc:title":["Solar Ultraviolet Radiation Exposure in Outdoor Work Environment at Bowling Green, Ohio"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Graduate Studies"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Occupational Health (MSOH)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}