{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1213734675"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1213734675","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development, validation and clinical application of finite element human pelvis model","abstract":"Finite element analysis became a very effective and essential tool in the studies of spinaland pelvic biomechanics. Most previous pelvic models included such simplifications asnon-complete pelvic structures presentation, non-physiologic properties of ligaments,model validation against just only one mode. Out study is the first attempt, to ourknowledge, to generate model with physiologic non-linear characteristic of theligamentous structures of sacroiliac joint and accurate presentation of entirely pelvicanatomy. The model validation against data in literature showed good prediction ofmotions in the sacroiliac joint and stress-distribution across pelvic bone. The clinicalapplication showed increased motions and stresses across sacroiliac joint which were notpreviously confirmed by the clinical and experimental studies due to their low sensitivityand specificity. The developed finite element human pelvis model might be a usefulinstrument in further clinical and biomechanical studies.","abstract_html":"Finite element analysis became a very effective and essential tool in the studies of spinaland pelvic biomechanics. Most previous pelvic models included such simplifications asnon-complete pelvic structures presentation, non-physiologic properties of ligaments,model validation against just only one mode. Out study is the first attempt, to ourknowledge, to generate model with physiologic non-linear characteristic of theligamentous structures of sacroiliac joint and accurate presentation of entirely pelvicanatomy. The model validation against data in literature showed good prediction ofmotions in the sacroiliac joint and stress-distribution across pelvic bone. The clinicalapplication showed increased motions and stresses across sacroiliac joint which were notpreviously confirmed by the clinical and experimental studies due to their low sensitivityand specificity. The developed finite element human pelvis model might be a usefulinstrument in further clinical and biomechanical studies.","abstract_has_math":false,"creators":["Ivanov, Alexander"],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Biomedical Sciences (MSBS)","degree_level":"masters","degree_discipline":"College of Graduate Studies","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Ebraheim, Nabil"],"committee_members":[],"year":2008,"date_issued":"2008-06-18","date_published":"2008-06-18","updated_at":"2026-11-27T04:17:19Z","subjects":["Surgery","finite element analysis","sacroiliac joint","pelvis"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1213734675","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1213734675","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1213734675","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1213734675","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ebraheim, Nabil"]},{"key":"dc:creator","label":"Author","values":["Ivanov, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-06-18"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Graduate Studies"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Sciences (MSBS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Surgery","finite element analysis","sacroiliac joint","pelvis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1213734675"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Finite element analysis became a very effective and essential tool in the studies of spinaland pelvic biomechanics. Most previous pelvic models included such simplifications asnon-complete pelvic structures presentation, non-physiologic properties of ligaments,model validation against just only one mode. Out study is the first attempt, to ourknowledge, to generate model with physiologic non-linear characteristic of theligamentous structures of sacroiliac joint and accurate presentation of entirely pelvicanatomy. The model validation against data in literature showed good prediction ofmotions in the sacroiliac joint and stress-distribution across pelvic bone. The clinicalapplication showed increased motions and stresses across sacroiliac joint which were notpreviously confirmed by the clinical and experimental studies due to their low sensitivityand specificity. The developed finite element human pelvis model might be a usefulinstrument in further clinical and biomechanical studies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.110","4.51 MB"]},{"key":"dc:title","label":"Title","values":["Development, validation and clinical application of finite element human pelvis model"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Ebraheim, Nabil"],"dc:creator":["Ivanov, Alexander"],"dc:date":["2008-06-18"],"dc:description":["Finite element analysis became a very effective and essential tool in the studies of spinaland pelvic biomechanics. Most previous pelvic models included such simplifications asnon-complete pelvic structures presentation, non-physiologic properties of ligaments,model validation against just only one mode. Out study is the first attempt, to ourknowledge, to generate model with physiologic non-linear characteristic of theligamentous structures of sacroiliac joint and accurate presentation of entirely pelvicanatomy. The model validation against data in literature showed good prediction ofmotions in the sacroiliac joint and stress-distribution across pelvic bone. The clinicalapplication showed increased motions and stresses across sacroiliac joint which were notpreviously confirmed by the clinical and experimental studies due to their low sensitivityand specificity. The developed finite element human pelvis model might be a usefulinstrument in further clinical and biomechanical studies."],"dc:format":["application/pdf","p.110","4.51 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1213734675"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Surgery","finite element analysis","sacroiliac joint","pelvis"],"dc:title":["Development, validation and clinical application of finite element human pelvis model"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Graduate Studies"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Sciences (MSBS)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}