{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1221066740"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1221066740","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Dosimetric Comparison of Superficial X-Rays and a Custom HDR Surface Applicator for the Treatment of Superficial Cancers","abstract":"The purpose of this study was to design and characterize a custom HDR applicator for the treatment of cancers in the region 0-5 mm, comparing it to the dosimetric properties of the MaximaR-100 superficial x-ray unit. The superficial machine was characterized in terms of percent depth dose, beam profiles, and dose rate and similar measurements were taken for the copper HDR applicator. The applicator alone had an unacceptably large dose inhomogeneity across the beam so a primary filter, modified filter, and secondary lead collimator were designed and manufactured to help shape the dose into a profile similar to the superficial applicator. Beam flatness and width were nearly replicated but beam divergence was more pronounced for the HDR applicators. Percent depth dose measurements for the HDR applicator showed a dose fall-off nearly identical to superficial x-rays rather than the assumed inverse square dose fall-off.","abstract_html":"The purpose of this study was to design and characterize a custom HDR applicator for the treatment of cancers in the region 0-5 mm, comparing it to the dosimetric properties of the MaximaR-100 superficial x-ray unit. The superficial machine was characterized in terms of percent depth dose, beam profiles, and dose rate and similar measurements were taken for the copper HDR applicator. The applicator alone had an unacceptably large dose inhomogeneity across the beam so a primary filter, modified filter, and secondary lead collimator were designed and manufactured to help shape the dose into a profile similar to the superficial applicator. Beam flatness and width were nearly replicated but beam divergence was more pronounced for the HDR applicators. Percent depth dose measurements for the HDR applicator showed a dose fall-off nearly identical to superficial x-rays rather than the assumed inverse square dose fall-off.","abstract_has_math":false,"creators":["Merz, Brandon A."],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Biomedical Sciences (MSBS)","degree_level":"masters","degree_discipline":"College of Graduate Studies","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Parsai, E. Ishmael"],"committee_members":[],"year":2008,"date_issued":"2008-11-12","date_published":"2008-11-12","updated_at":"2026-11-27T04:17:19Z","subjects":["Oncology","HDR","orthovoltage","custom applicator","filter","superficial","flattening filter"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1221066740","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1221066740","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1221066740","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1221066740","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Parsai, E. Ishmael"]},{"key":"dc:creator","label":"Author","values":["Merz, Brandon A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-11-12"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Graduate Studies"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Sciences (MSBS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Oncology","HDR","orthovoltage","custom applicator","filter","superficial","flattening filter"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1221066740"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to design and characterize a custom HDR applicator for the treatment of cancers in the region 0-5 mm, comparing it to the dosimetric properties of the MaximaR-100 superficial x-ray unit. The superficial machine was characterized in terms of percent depth dose, beam profiles, and dose rate and similar measurements were taken for the copper HDR applicator. The applicator alone had an unacceptably large dose inhomogeneity across the beam so a primary filter, modified filter, and secondary lead collimator were designed and manufactured to help shape the dose into a profile similar to the superficial applicator. Beam flatness and width were nearly replicated but beam divergence was more pronounced for the HDR applicators. Percent depth dose measurements for the HDR applicator showed a dose fall-off nearly identical to superficial x-rays rather than the assumed inverse square dose fall-off."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.46","754.2 KB"]},{"key":"dc:title","label":"Title","values":["Dosimetric Comparison of Superficial X-Rays and a Custom HDR Surface Applicator for the Treatment of Superficial Cancers"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Parsai, E. Ishmael"],"dc:creator":["Merz, Brandon A."],"dc:date":["2008-11-12"],"dc:description":["The purpose of this study was to design and characterize a custom HDR applicator for the treatment of cancers in the region 0-5 mm, comparing it to the dosimetric properties of the MaximaR-100 superficial x-ray unit. The superficial machine was characterized in terms of percent depth dose, beam profiles, and dose rate and similar measurements were taken for the copper HDR applicator. The applicator alone had an unacceptably large dose inhomogeneity across the beam so a primary filter, modified filter, and secondary lead collimator were designed and manufactured to help shape the dose into a profile similar to the superficial applicator. Beam flatness and width were nearly replicated but beam divergence was more pronounced for the HDR applicators. Percent depth dose measurements for the HDR applicator showed a dose fall-off nearly identical to superficial x-rays rather than the assumed inverse square dose fall-off."],"dc:format":["application/pdf","p.46","754.2 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1221066740"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Oncology","HDR","orthovoltage","custom applicator","filter","superficial","flattening filter"],"dc:title":["Dosimetric Comparison of Superficial X-Rays and a Custom HDR Surface Applicator for the Treatment of Superficial Cancers"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Graduate Studies"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Sciences (MSBS)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}