{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1263404507"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1263404507","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Impact of Bilateral Filter Parameters on Medical Image Noise Reduction and Edge Preservation","abstract":"The objective of this paper is to examine the bilateral filter and its application to digitalmedical imaging. The bilateral filter is a non-linear adaptive smoothing filter which iscapable of preserving the edges of image structures. Selection of the bilateral filter’sparameters greatly influence how well an image is smoothed and how well edges are preserved.The parameters of the bilateral filter were analyzed individually. The noise reduction foreach parameter is related to the much simpler box (averaging) filter. Edges were alsoanalyzed for each parameter. Techniques for proper parameter selection are studied andgeneral guidelines are suggested. After the properties of each parameter were examined,they were recombined and applied to CT images. Solutions addressing the limitations ofthis filter for high noise CT images are also considered.It was found that the bilateral filter is capable of providing effective smoothing and at thesame time preserves edges which are otherwise blurred by other filters. The viability ofthis filter greatly depends on the selection of its parameters.","abstract_html":"The objective of this paper is to examine the bilateral filter and its application to digitalmedical imaging. The bilateral filter is a non-linear adaptive smoothing filter which iscapable of preserving the edges of image structures. Selection of the bilateral filter’sparameters greatly influence how well an image is smoothed and how well edges are preserved.The parameters of the bilateral filter were analyzed individually. The noise reduction foreach parameter is related to the much simpler box (averaging) filter. Edges were alsoanalyzed for each parameter. Techniques for proper parameter selection are studied andgeneral guidelines are suggested. After the properties of each parameter were examined,they were recombined and applied to CT images. Solutions addressing the limitations ofthis filter for high noise CT images are also considered.It was found that the bilateral filter is capable of providing effective smoothing and at thesame time preserves edges which are otherwise blurred by other filters. The viability ofthis filter greatly depends on the selection of its parameters.","abstract_has_math":false,"creators":["Lekan, Michael D."],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Biomedical Sciences (MSBS)","degree_level":"masters","degree_discipline":"College of Medicine","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Dennis, Michael"],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-27T04:17:19Z","subjects":["Computer Science","Radiology","Biomedical Research","bilateral filter","adaptive filtering","image processing","medical imaging","non-linear filtering","CT imaging"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1263404507","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1263404507","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1263404507","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1263404507","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Dennis, Michael"]},{"key":"dc:creator","label":"Author","values":["Lekan, Michael D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Medicine"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Sciences (MSBS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Science","Radiology","Biomedical Research","bilateral filter","adaptive filtering","image processing","medical imaging","non-linear filtering","CT imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1263404507"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The objective of this paper is to examine the bilateral filter and its application to digitalmedical imaging. The bilateral filter is a non-linear adaptive smoothing filter which iscapable of preserving the edges of image structures. Selection of the bilateral filter’sparameters greatly influence how well an image is smoothed and how well edges are preserved.The parameters of the bilateral filter were analyzed individually. The noise reduction foreach parameter is related to the much simpler box (averaging) filter. Edges were alsoanalyzed for each parameter. Techniques for proper parameter selection are studied andgeneral guidelines are suggested. After the properties of each parameter were examined,they were recombined and applied to CT images. Solutions addressing the limitations ofthis filter for high noise CT images are also considered.It was found that the bilateral filter is capable of providing effective smoothing and at thesame time preserves edges which are otherwise blurred by other filters. The viability ofthis filter greatly depends on the selection of its parameters."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.109","3.07 MB"]},{"key":"dc:title","label":"Title","values":["Impact of Bilateral Filter Parameters on Medical Image Noise Reduction and Edge Preservation"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Dennis, Michael"],"dc:creator":["Lekan, Michael D."],"dc:date":["2009"],"dc:description":["The objective of this paper is to examine the bilateral filter and its application to digitalmedical imaging. The bilateral filter is a non-linear adaptive smoothing filter which iscapable of preserving the edges of image structures. Selection of the bilateral filter’sparameters greatly influence how well an image is smoothed and how well edges are preserved.The parameters of the bilateral filter were analyzed individually. The noise reduction foreach parameter is related to the much simpler box (averaging) filter. Edges were alsoanalyzed for each parameter. Techniques for proper parameter selection are studied andgeneral guidelines are suggested. After the properties of each parameter were examined,they were recombined and applied to CT images. Solutions addressing the limitations ofthis filter for high noise CT images are also considered.It was found that the bilateral filter is capable of providing effective smoothing and at thesame time preserves edges which are otherwise blurred by other filters. The viability ofthis filter greatly depends on the selection of its parameters."],"dc:format":["application/pdf","p.109","3.07 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1263404507"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Computer Science","Radiology","Biomedical Research","bilateral filter","adaptive filtering","image processing","medical imaging","non-linear filtering","CT imaging"],"dc:title":["Impact of Bilateral Filter Parameters on Medical Image Noise Reduction and Edge Preservation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Medicine"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Sciences (MSBS)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:19Z"}