{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:mco1331557547"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:mco1331557547","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of an Automated Program for Calculating Radiation Shielding in a Radiotherapy Vault","abstract":"<p>The software program, Automatic Radiotherapy Vault Calculator, is designed to provide quick and accurate calculation of required shielding for radiotherapy vaults. Utilizing values entered by the user and various conditional lookup tables, the program is able to calculate: machine workload, primary barrier thickness, secondary barrier thickness, and the entrance door thickness for shilding considerations of both photons and neutrons generated in the treatment room. </p><p> The purpose of this work is to compare the calculations performed by this program to the calculations suggested in the National Council on Radiation Protection and Measurement’s report 151 for primary beam, scattered beam, and neutron shielding applications. Automatic Radiotherapy Vault Calculator succeeds in providing timely and accurate calculations of required barrier thicknesses and in material conversion calculations for the retrofitting of a previously built vault.</p>","abstract_html":"&lt;p&gt;The software program, Automatic Radiotherapy Vault Calculator, is designed to provide quick and accurate calculation of required shielding for radiotherapy vaults. Utilizing values entered by the user and various conditional lookup tables, the program is able to calculate: machine workload, primary barrier thickness, secondary barrier thickness, and the entrance door thickness for shilding considerations of both photons and neutrons generated in the treatment room. &lt;/p&gt;&lt;p&gt; The purpose of this work is to compare the calculations performed by this program to the calculations suggested in the National Council on Radiation Protection and Measurement’s report 151 for primary beam, scattered beam, and neutron shielding applications. Automatic Radiotherapy Vault Calculator succeeds in providing timely and accurate calculations of required barrier thicknesses and in material conversion calculations for the retrofitting of a previously built vault.&lt;/p&gt;","abstract_has_math":false,"creators":["Rhodes, Charles Ray, III"],"institution":"University of Toledo Health Science Campus","degree_name":"Master of Science in Biomedical Sciences (MSBS)","degree_level":"masters","degree_discipline":"College of Medicine","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Parsai, E. Ishmael"],"committee_members":[],"year":2012,"date_issued":"2012-05-16","date_published":"2012-05-16","updated_at":"2026-11-27T04:17:26Z","subjects":["Oncology","Physics","Radiation","Radiation Shielding","Program","Radiation Safety","Radiation Oncology"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1331557547","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=mco1331557547","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amco1331557547","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amco1331557547","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Parsai, E. Ishmael"]},{"key":"dc:creator","label":"Author","values":["Rhodes, Charles Ray, III"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-05-16"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo Health Science Campus / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Medicine"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Sciences (MSBS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo Health Science Campus"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Oncology","Physics","Radiation","Radiation Shielding","Program","Radiation Safety","Radiation Oncology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1331557547"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The software program, Automatic Radiotherapy Vault Calculator, is designed to provide quick and accurate calculation of required shielding for radiotherapy vaults. Utilizing values entered by the user and various conditional lookup tables, the program is able to calculate: machine workload, primary barrier thickness, secondary barrier thickness, and the entrance door thickness for shilding considerations of both photons and neutrons generated in the treatment room. </p><p> The purpose of this work is to compare the calculations performed by this program to the calculations suggested in the National Council on Radiation Protection and Measurement’s report 151 for primary beam, scattered beam, and neutron shielding applications. Automatic Radiotherapy Vault Calculator succeeds in providing timely and accurate calculations of required barrier thicknesses and in material conversion calculations for the retrofitting of a previously built vault.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.99","854.2 KB"]},{"key":"dc:title","label":"Title","values":["Development of an Automated Program for Calculating Radiation Shielding in a Radiotherapy Vault"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Parsai, E. Ishmael"],"dc:creator":["Rhodes, Charles Ray, III"],"dc:date":["2012-05-16"],"dc:description":["<p>The software program, Automatic Radiotherapy Vault Calculator, is designed to provide quick and accurate calculation of required shielding for radiotherapy vaults. Utilizing values entered by the user and various conditional lookup tables, the program is able to calculate: machine workload, primary barrier thickness, secondary barrier thickness, and the entrance door thickness for shilding considerations of both photons and neutrons generated in the treatment room. </p><p> The purpose of this work is to compare the calculations performed by this program to the calculations suggested in the National Council on Radiation Protection and Measurement’s report 151 for primary beam, scattered beam, and neutron shielding applications. Automatic Radiotherapy Vault Calculator succeeds in providing timely and accurate calculations of required barrier thicknesses and in material conversion calculations for the retrofitting of a previously built vault.</p>"],"dc:format":["application/pdf","p.99","854.2 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=mco1331557547"],"dc:language":["English"],"dc:publisher":["University of Toledo Health Science Campus / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Oncology","Physics","Radiation","Radiation Shielding","Program","Radiation Safety","Radiation Oncology"],"dc:title":["Development of an Automated Program for Calculating Radiation Shielding in a Radiotherapy Vault"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Medicine"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Sciences (MSBS)"],"thesis:institution_name":["University of Toledo Health Science Campus"]},"updated_at":"2026-11-27T04:17:26Z"}