{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:miami1250281122"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:miami1250281122","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"MAGNETIC RESONANCE IN THE PROXIMITY OF AN INSTABILITY: PERPENDICULAR RESONANCE IN PERMALLOY NEAR THE CRITICAL FIELD","abstract":"The linear relationship between resonant frequency as a function of applied magneticfield was investigated using a FMR experimental technique for the field perpendicular toa Permalloy thin film. Measurements were taken near a critical point (Happlied=4πM),which occurs at low frequencies in the frequency versus field curve. In order to do this, aspecial apparatus had to be designed and constructed so that the film could be preciselyoriented. The design and operation of this apparatus can provide angular adjustments ontwo axes to within 0.01°. It was also necessary to design and make a waveguide thatoperated between 8.0 GHz and 1.6 GHz. It was found that the high field resonance peakfollowed a linear dispersion while the low field resonant peak followed a nonlineardispersion that appeared to result from local areas of the sample not beingperpendicularly aligned.","abstract_html":"The linear relationship between resonant frequency as a function of applied magneticfield was investigated using a FMR experimental technique for the field perpendicular toa Permalloy thin film. Measurements were taken near a critical point (Happlied=4πM),which occurs at low frequencies in the frequency versus field curve. In order to do this, aspecial apparatus had to be designed and constructed so that the film could be preciselyoriented. The design and operation of this apparatus can provide angular adjustments ontwo axes to within 0.01°. It was also necessary to design and make a waveguide thatoperated between 8.0 GHz and 1.6 GHz. It was found that the high field resonance peakfollowed a linear dispersion while the low field resonant peak followed a nonlineardispersion that appeared to result from local areas of the sample not beingperpendicularly aligned.","abstract_has_math":false,"creators":["Bechtel, Kyle A."],"institution":"Miami University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Pechan, Michael"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-08-17","date_published":"2009-08-17","updated_at":"2026-11-27T04:17:43Z","subjects":["Electromagnetism","Physics","FMR","resonance","Permalloy","perpendicular","applied field","field","angular dependence"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=miami1250281122","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=miami1250281122","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amiami1250281122","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amiami1250281122","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pechan, Michael"]},{"key":"dc:creator","label":"Author","values":["Bechtel, Kyle A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-08-17"]},{"key":"dc:publisher","label":"Institution","values":["Miami University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Miami University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electromagnetism","Physics","FMR","resonance","Permalloy","perpendicular","applied field","field","angular dependence"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=miami1250281122"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The linear relationship between resonant frequency as a function of applied magneticfield was investigated using a FMR experimental technique for the field perpendicular toa Permalloy thin film. Measurements were taken near a critical point (Happlied=4πM),which occurs at low frequencies in the frequency versus field curve. In order to do this, aspecial apparatus had to be designed and constructed so that the film could be preciselyoriented. The design and operation of this apparatus can provide angular adjustments ontwo axes to within 0.01°. It was also necessary to design and make a waveguide thatoperated between 8.0 GHz and 1.6 GHz. It was found that the high field resonance peakfollowed a linear dispersion while the low field resonant peak followed a nonlineardispersion that appeared to result from local areas of the sample not beingperpendicularly aligned."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.45","11.57 MB"]},{"key":"dc:title","label":"Title","values":["MAGNETIC RESONANCE IN THE PROXIMITY OF AN INSTABILITY: PERPENDICULAR RESONANCE IN PERMALLOY NEAR THE CRITICAL FIELD"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pechan, Michael"],"dc:creator":["Bechtel, Kyle A."],"dc:date":["2009-08-17"],"dc:description":["The linear relationship between resonant frequency as a function of applied magneticfield was investigated using a FMR experimental technique for the field perpendicular toa Permalloy thin film. Measurements were taken near a critical point (Happlied=4πM),which occurs at low frequencies in the frequency versus field curve. In order to do this, aspecial apparatus had to be designed and constructed so that the film could be preciselyoriented. The design and operation of this apparatus can provide angular adjustments ontwo axes to within 0.01°. It was also necessary to design and make a waveguide thatoperated between 8.0 GHz and 1.6 GHz. It was found that the high field resonance peakfollowed a linear dispersion while the low field resonant peak followed a nonlineardispersion that appeared to result from local areas of the sample not beingperpendicularly aligned."],"dc:format":["application/pdf","p.45","11.57 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=miami1250281122"],"dc:language":["English"],"dc:publisher":["Miami University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electromagnetism","Physics","FMR","resonance","Permalloy","perpendicular","applied field","field","angular dependence"],"dc:title":["MAGNETIC RESONANCE IN THE PROXIMITY OF AN INSTABILITY: PERPENDICULAR RESONANCE IN PERMALLOY NEAR THE CRITICAL FIELD"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Miami University"]},"updated_at":"2026-11-27T04:17:43Z"}