{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:miami1310145461"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:miami1310145461","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Novel heat exchanger fin surface design for improved condensate management","abstract":"The objective of this work was to assess the effectiveness of round tube, plain fin heat exchangers constructed from anisotropic aluminum fins to more completely drain the condensate formed on the heat transfer surface during normal operation. This study critically evaluates the behavior of condensate droplets on micro-grooved fins as well as the efficacy of full-scale heat exchangers by measuring dynamic contact angles, critical inclination angles for sliding, dynamic dip testing data, and the air-side heat transfer coefficient under both dry and wet operating conditions. The results show that the micro-grooved structure of the fin in combination with the alkyl silane coating increased the hydrophobicity of the surface and reduced the water retention of the heat exchanger by more than 27%. In addition, these prototype fin surfaces were shown to have a negligible effect on the heat transfer coefficient under both dry and wet conditions while at the same time reducing the wet air-side pressure drop thereby decreasing fan power consumption. This paper also presents data pertaining to the durability of the alkyl silane coating and recommendations for further study.","abstract_html":"The objective of this work was to assess the effectiveness of round tube, plain fin heat exchangers constructed from anisotropic aluminum fins to more completely drain the condensate formed on the heat transfer surface during normal operation. This study critically evaluates the behavior of condensate droplets on micro-grooved fins as well as the efficacy of full-scale heat exchangers by measuring dynamic contact angles, critical inclination angles for sliding, dynamic dip testing data, and the air-side heat transfer coefficient under both dry and wet operating conditions. The results show that the micro-grooved structure of the fin in combination with the alkyl silane coating increased the hydrophobicity of the surface and reduced the water retention of the heat exchanger by more than 27%. In addition, these prototype fin surfaces were shown to have a negligible effect on the heat transfer coefficient under both dry and wet conditions while at the same time reducing the wet air-side pressure drop thereby decreasing fan power consumption. This paper also presents data pertaining to the durability of the alkyl silane coating and recommendations for further study.","abstract_has_math":false,"creators":["Yu, Rong"],"institution":"Miami University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Chemical, Paper and Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sommers, Andrew"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-07-13","date_published":"2011-07-13","updated_at":"2026-11-27T04:17:52Z","subjects":["air-conditioning","condensate","anisotropic fins","micro-channels","dip testing","heat transfer"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=miami1310145461","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=miami1310145461","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Amiami1310145461","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Amiami1310145461","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sommers, Andrew"]},{"key":"dc:creator","label":"Author","values":["Yu, Rong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-07-13"]},{"key":"dc:publisher","label":"Institution","values":["Miami University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical, Paper and Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Miami University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["air-conditioning","condensate","anisotropic fins","micro-channels","dip testing","heat transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=miami1310145461"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The objective of this work was to assess the effectiveness of round tube, plain fin heat exchangers constructed from anisotropic aluminum fins to more completely drain the condensate formed on the heat transfer surface during normal operation. This study critically evaluates the behavior of condensate droplets on micro-grooved fins as well as the efficacy of full-scale heat exchangers by measuring dynamic contact angles, critical inclination angles for sliding, dynamic dip testing data, and the air-side heat transfer coefficient under both dry and wet operating conditions. The results show that the micro-grooved structure of the fin in combination with the alkyl silane coating increased the hydrophobicity of the surface and reduced the water retention of the heat exchanger by more than 27%. In addition, these prototype fin surfaces were shown to have a negligible effect on the heat transfer coefficient under both dry and wet conditions while at the same time reducing the wet air-side pressure drop thereby decreasing fan power consumption. This paper also presents data pertaining to the durability of the alkyl silane coating and recommendations for further study."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.71 MB"]},{"key":"dc:title","label":"Title","values":["Novel heat exchanger fin surface design for improved condensate management"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sommers, Andrew"],"dc:creator":["Yu, Rong"],"dc:date":["2011-07-13"],"dc:description":["The objective of this work was to assess the effectiveness of round tube, plain fin heat exchangers constructed from anisotropic aluminum fins to more completely drain the condensate formed on the heat transfer surface during normal operation. This study critically evaluates the behavior of condensate droplets on micro-grooved fins as well as the efficacy of full-scale heat exchangers by measuring dynamic contact angles, critical inclination angles for sliding, dynamic dip testing data, and the air-side heat transfer coefficient under both dry and wet operating conditions. The results show that the micro-grooved structure of the fin in combination with the alkyl silane coating increased the hydrophobicity of the surface and reduced the water retention of the heat exchanger by more than 27%. In addition, these prototype fin surfaces were shown to have a negligible effect on the heat transfer coefficient under both dry and wet conditions while at the same time reducing the wet air-side pressure drop thereby decreasing fan power consumption. This paper also presents data pertaining to the durability of the alkyl silane coating and recommendations for further study."],"dc:format":["application/pdf","1.71 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=miami1310145461"],"dc:language":["English"],"dc:publisher":["Miami University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["air-conditioning","condensate","anisotropic fins","micro-channels","dip testing","heat transfer"],"dc:title":["Novel heat exchanger fin surface design for improved condensate management"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical, Paper and Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Miami University"]},"updated_at":"2026-11-27T04:17:52Z"}