{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ohiou1126909697"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ohiou1126909697","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Capture of Soluble Mercury Using Membrane-Based Wet Electrostatic Precipitator as a Function of Temperature","abstract":"<p>Concern over the difficulty of limiting emissions of trace amounts of hazardous air pollutants in large flue gas streams to meet potential environmental regulations has been a driving force for the development and characterization of control technologies for utility boilers. In cooperation with Ohio University and Ohio Coal Development office, Ohio Coal Research Center has been conducting advanced studies of mercury removal using membrane based wet electrostatic precipitator (ESP). This ESP in which heavy metal plates are replaced by light and thin membranes made from Omnisil 1000 (silica fiber) could be beneficial for wet precipitators as a cost-effective control of mercury emissions. This research conducted on bench scale has proved the effectiveness of using membrane wet precipitation to facilitate and enhance capture of soluble mercury. Ontario Hydro Method (OHM), which is a generally accepted method to measure Hg in utility coal-fired boilers, was the designated method to sample and analyze for Hg in flue gas stream.</p>","abstract_html":"&lt;p&gt;Concern over the difficulty of limiting emissions of trace amounts of hazardous air pollutants in large flue gas streams to meet potential environmental regulations has been a driving force for the development and characterization of control technologies for utility boilers. In cooperation with Ohio University and Ohio Coal Development office, Ohio Coal Research Center has been conducting advanced studies of mercury removal using membrane based wet electrostatic precipitator (ESP). This ESP in which heavy metal plates are replaced by light and thin membranes made from Omnisil 1000 (silica fiber) could be beneficial for wet precipitators as a cost-effective control of mercury emissions. This research conducted on bench scale has proved the effectiveness of using membrane wet precipitation to facilitate and enhance capture of soluble mercury. Ontario Hydro Method (OHM), which is a generally accepted method to measure Hg in utility coal-fired boilers, was the designated method to sample and analyze for Hg in flue gas stream.&lt;/p&gt;","abstract_has_math":false,"creators":["Yatavelli, Laxmi Narasimha R."],"institution":"Ohio University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Mechanical Engineering (Engineering)","degree_department":null,"school":null,"contributors":[],"advisors":["Bayless, David"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-12-08","date_published":"2005-12-08","updated_at":"2026-11-27T04:18:18Z","subjects":["Engineering, Mechanical","Mercury control","Electrostatic precipitator","Wet membrane ESP"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1126909697","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1126909697","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aohiou1126909697","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aohiou1126909697","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bayless, David"]},{"key":"dc:creator","label":"Author","values":["Yatavelli, Laxmi Narasimha R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-12-08"]},{"key":"dc:publisher","label":"Institution","values":["Ohio University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering (Engineering)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ohio University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Mechanical","Mercury control","Electrostatic precipitator","Wet membrane ESP"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1126909697"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Concern over the difficulty of limiting emissions of trace amounts of hazardous air pollutants in large flue gas streams to meet potential environmental regulations has been a driving force for the development and characterization of control technologies for utility boilers. In cooperation with Ohio University and Ohio Coal Development office, Ohio Coal Research Center has been conducting advanced studies of mercury removal using membrane based wet electrostatic precipitator (ESP). This ESP in which heavy metal plates are replaced by light and thin membranes made from Omnisil 1000 (silica fiber) could be beneficial for wet precipitators as a cost-effective control of mercury emissions. This research conducted on bench scale has proved the effectiveness of using membrane wet precipitation to facilitate and enhance capture of soluble mercury. Ontario Hydro Method (OHM), which is a generally accepted method to measure Hg in utility coal-fired boilers, was the designated method to sample and analyze for Hg in flue gas stream.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.97","1.68 MB"]},{"key":"dc:title","label":"Title","values":["Capture of Soluble Mercury Using Membrane-Based Wet Electrostatic Precipitator as a Function of Temperature"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bayless, David"],"dc:creator":["Yatavelli, Laxmi Narasimha R."],"dc:date":["2005-12-08"],"dc:description":["<p>Concern over the difficulty of limiting emissions of trace amounts of hazardous air pollutants in large flue gas streams to meet potential environmental regulations has been a driving force for the development and characterization of control technologies for utility boilers. In cooperation with Ohio University and Ohio Coal Development office, Ohio Coal Research Center has been conducting advanced studies of mercury removal using membrane based wet electrostatic precipitator (ESP). This ESP in which heavy metal plates are replaced by light and thin membranes made from Omnisil 1000 (silica fiber) could be beneficial for wet precipitators as a cost-effective control of mercury emissions. This research conducted on bench scale has proved the effectiveness of using membrane wet precipitation to facilitate and enhance capture of soluble mercury. Ontario Hydro Method (OHM), which is a generally accepted method to measure Hg in utility coal-fired boilers, was the designated method to sample and analyze for Hg in flue gas stream.</p>"],"dc:format":["application/pdf","p.97","1.68 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1126909697"],"dc:language":["English"],"dc:publisher":["Ohio University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Mechanical","Mercury control","Electrostatic precipitator","Wet membrane ESP"],"dc:title":["Capture of Soluble Mercury Using Membrane-Based Wet Electrostatic Precipitator as a Function of Temperature"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering (Engineering)"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Ohio University"]},"updated_at":"2026-11-27T04:18:18Z"}