{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1078788946"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1078788946","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Study of thin-wall injection molding","abstract":"Thin-wall injection molding has received increasing attention. However, the combination of viscoelastic materials, complex molding geometry and cyclic processing conditions has generated some problems. In this study, alternate and synchronous dull and glossy flow marks, two surface quality problems, were studied. The effect of polymer rheology, mold geometry, operating variables, and mold surface coatings on the appearance of the flow marks was studied. The flow marks occurred above a critical wall shear stress, but disappeared at high injection speeds. Mold geometry and mold temperature were found to affect the wavelength and the width of the flow marks, while melt temperature did not have much effect. Mold surface coatings did not eliminate the flow marks, and slip was not the cause of the generation of the alternate flow marks. The generation of these flow marks was explained by an entry viscoelastic flow instability. Furthermore, thin-wall injection molding with micro-features was investigated. The filling length in microchannels was measured and compared with simulation. The heat transfer coefficient was found to be very sensitive to the filling length prediction. In order to investigate the effect of input properties on the simulation output, mold cavity pressure was studied. The goal was to understand the effect of pressure-dependent viscosity, heat capacity, heat transfer coefficient, juncture pressure loss and pvT-data on cavity pressure and pressure drop prediction, and evaluate the importance of each parameter. The cavity pressure and pressure drop were measured experimentally and compared. Furthermore, the method to improve the prediction accuracy was discussed to help design and predict. The final part of the research focuses on the mechanical and rheological properties of virgin and recycled high impact polystyrene materials. In this study, we describe our progress in evaluating the viability of reusing post-consumer and virgin polymer blends of HIPS from electronics equipment housings. Plastics reuse challenges are briefly reviewed, and experimental results, such as rheological properties, mechanical properties, molecular weight and morphology of different blends, are summarized and discussed for reuse of HIPS. Finally, the study introduces a new approach to determine initial processing parameters for thin-wall injection molding of post-consumer resin.","abstract_html":"Thin-wall injection molding has received increasing attention. However, the combination of viscoelastic materials, complex molding geometry and cyclic processing conditions has generated some problems. In this study, alternate and synchronous dull and glossy flow marks, two surface quality problems, were studied. The effect of polymer rheology, mold geometry, operating variables, and mold surface coatings on the appearance of the flow marks was studied. The flow marks occurred above a critical wall shear stress, but disappeared at high injection speeds. Mold geometry and mold temperature were found to affect the wavelength and the width of the flow marks, while melt temperature did not have much effect. Mold surface coatings did not eliminate the flow marks, and slip was not the cause of the generation of the alternate flow marks. The generation of these flow marks was explained by an entry viscoelastic flow instability. Furthermore, thin-wall injection molding with micro-features was investigated. The filling length in microchannels was measured and compared with simulation. The heat transfer coefficient was found to be very sensitive to the filling length prediction. In order to investigate the effect of input properties on the simulation output, mold cavity pressure was studied. The goal was to understand the effect of pressure-dependent viscosity, heat capacity, heat transfer coefficient, juncture pressure loss and pvT-data on cavity pressure and pressure drop prediction, and evaluate the importance of each parameter. The cavity pressure and pressure drop were measured experimentally and compared. Furthermore, the method to improve the prediction accuracy was discussed to help design and predict. The final part of the research focuses on the mechanical and rheological properties of virgin and recycled high impact polystyrene materials. In this study, we describe our progress in evaluating the viability of reusing post-consumer and virgin polymer blends of HIPS from electronics equipment housings. Plastics reuse challenges are briefly reviewed, and experimental results, such as rheological properties, mechanical properties, molecular weight and morphology of different blends, are summarized and discussed for reuse of HIPS. Finally, the study introduces a new approach to determine initial processing parameters for thin-wall injection molding of post-consumer resin.","abstract_has_math":false,"creators":["Xu, Guojung"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["KOELLING, KURT"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-03-10","date_published":"2004-03-10","updated_at":"2026-11-27T04:31:57Z","subjects":["Engineering, Chemical","INJECTION MOLDING","FLOW MARKS","MICROFEATURE","CAVITY PRESSURE","REUSE."],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1078788946","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1078788946","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1078788946","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1078788946","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["KOELLING, KURT"]},{"key":"dc:creator","label":"Author","values":["Xu, Guojung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-03-10"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Chemical","INJECTION MOLDING","FLOW MARKS","MICROFEATURE","CAVITY PRESSURE","REUSE."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1078788946"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thin-wall injection molding has received increasing attention. However, the combination of viscoelastic materials, complex molding geometry and cyclic processing conditions has generated some problems. In this study, alternate and synchronous dull and glossy flow marks, two surface quality problems, were studied. The effect of polymer rheology, mold geometry, operating variables, and mold surface coatings on the appearance of the flow marks was studied. The flow marks occurred above a critical wall shear stress, but disappeared at high injection speeds. Mold geometry and mold temperature were found to affect the wavelength and the width of the flow marks, while melt temperature did not have much effect. Mold surface coatings did not eliminate the flow marks, and slip was not the cause of the generation of the alternate flow marks. The generation of these flow marks was explained by an entry viscoelastic flow instability. Furthermore, thin-wall injection molding with micro-features was investigated. The filling length in microchannels was measured and compared with simulation. The heat transfer coefficient was found to be very sensitive to the filling length prediction. In order to investigate the effect of input properties on the simulation output, mold cavity pressure was studied. The goal was to understand the effect of pressure-dependent viscosity, heat capacity, heat transfer coefficient, juncture pressure loss and pvT-data on cavity pressure and pressure drop prediction, and evaluate the importance of each parameter. The cavity pressure and pressure drop were measured experimentally and compared. Furthermore, the method to improve the prediction accuracy was discussed to help design and predict. The final part of the research focuses on the mechanical and rheological properties of virgin and recycled high impact polystyrene materials. In this study, we describe our progress in evaluating the viability of reusing post-consumer and virgin polymer blends of HIPS from electronics equipment housings. Plastics reuse challenges are briefly reviewed, and experimental results, such as rheological properties, mechanical properties, molecular weight and morphology of different blends, are summarized and discussed for reuse of HIPS. Finally, the study introduces a new approach to determine initial processing parameters for thin-wall injection molding of post-consumer resin."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.238","1.73 MB"]},{"key":"dc:title","label":"Title","values":["Study of thin-wall injection molding"]}]}],"canonical_facts":{"dc:contributor.advisor":["KOELLING, KURT"],"dc:creator":["Xu, Guojung"],"dc:date":["2004-03-10"],"dc:description":["Thin-wall injection molding has received increasing attention. However, the combination of viscoelastic materials, complex molding geometry and cyclic processing conditions has generated some problems. In this study, alternate and synchronous dull and glossy flow marks, two surface quality problems, were studied. The effect of polymer rheology, mold geometry, operating variables, and mold surface coatings on the appearance of the flow marks was studied. The flow marks occurred above a critical wall shear stress, but disappeared at high injection speeds. Mold geometry and mold temperature were found to affect the wavelength and the width of the flow marks, while melt temperature did not have much effect. Mold surface coatings did not eliminate the flow marks, and slip was not the cause of the generation of the alternate flow marks. The generation of these flow marks was explained by an entry viscoelastic flow instability. Furthermore, thin-wall injection molding with micro-features was investigated. The filling length in microchannels was measured and compared with simulation. The heat transfer coefficient was found to be very sensitive to the filling length prediction. In order to investigate the effect of input properties on the simulation output, mold cavity pressure was studied. The goal was to understand the effect of pressure-dependent viscosity, heat capacity, heat transfer coefficient, juncture pressure loss and pvT-data on cavity pressure and pressure drop prediction, and evaluate the importance of each parameter. The cavity pressure and pressure drop were measured experimentally and compared. Furthermore, the method to improve the prediction accuracy was discussed to help design and predict. The final part of the research focuses on the mechanical and rheological properties of virgin and recycled high impact polystyrene materials. In this study, we describe our progress in evaluating the viability of reusing post-consumer and virgin polymer blends of HIPS from electronics equipment housings. Plastics reuse challenges are briefly reviewed, and experimental results, such as rheological properties, mechanical properties, molecular weight and morphology of different blends, are summarized and discussed for reuse of HIPS. Finally, the study introduces a new approach to determine initial processing parameters for thin-wall injection molding of post-consumer resin."],"dc:format":["application/pdf","p.238","1.73 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1078788946"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Chemical","INJECTION MOLDING","FLOW MARKS","MICROFEATURE","CAVITY PRESSURE","REUSE."],"dc:title":["Study of thin-wall injection molding"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:31:57Z"}