{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1099068680"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1099068680","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Immunomagnetic cell separation: continued development of fundamental model of magnetophoretic mobility and further applications","abstract":"In this study, the theoretical model for magnetophoretic mobility was further developed to include the contribution of intrinsic properties of particles or cells and the influence of the properties of the suspending fluid. Using these improvements, the dependence of the magnetophoretic mobility of unlabeled cells/microspheres and cells/microspheres labeled with colloidal magnetic labels on suspending fluid was used to determine the magnetic susceptibility of cells/microspheres and colloidal labels. The combination of these theoretical improvements, and the experimental studies, makes the methodology developed a universal characterization method. To explain the dependence of magnetophoretic mobility or fluorescence intensity on concentrations of the affinity labels, a binding model was proposed. Good agreement was found for lymphocytes labeled with anti CD3 antibody conjugates and the model. The data indicated that the conjugation of larger magnetic labels decreases the binding affinity of the antigen antibody interaction and the antibody binding capacity (ABC). A scale up model was then proposed, and experimentally verified on larger scale immunological labeling. This model assists in other projects in our lab focused on the efficient magnetic cell sorting at large scale. Restricted by high autofluorescence levels, alveolar macrophages, are difficult to analyze using flow cytometry. Immunomagnetically based CTV system was studied to evaluate if CTV can be used as an alternative of flow cytometry on quantitative cellular receptor study. A good agreement between CTV and FCM was found when monocytes were studied. CTV was then successfully used to analyze AM cells for basal receptor expression, and the expression kinetics when LPS was used for activation. CTV was used to determine if proteins can be immunomagnetically separated via the use of colloidal labels or molecular labels by measuring the magnetism of a labeled protein. Feasibility of the separation process was determined by calculating the retention ratio. It was shown that proteins can be separated immunomagnetically with the use of colloidal labels, such as DM beads, but not with the use of molecular labels used in the study, ferritin. Immunomagnetic cell separation was also successfully applied to separate Bacillus cereus spores from food.","abstract_html":"In this study, the theoretical model for magnetophoretic mobility was further developed to include the contribution of intrinsic properties of particles or cells and the influence of the properties of the suspending fluid. Using these improvements, the dependence of the magnetophoretic mobility of unlabeled cells/microspheres and cells/microspheres labeled with colloidal magnetic labels on suspending fluid was used to determine the magnetic susceptibility of cells/microspheres and colloidal labels. The combination of these theoretical improvements, and the experimental studies, makes the methodology developed a universal characterization method. To explain the dependence of magnetophoretic mobility or fluorescence intensity on concentrations of the affinity labels, a binding model was proposed. Good agreement was found for lymphocytes labeled with anti CD3 antibody conjugates and the model. The data indicated that the conjugation of larger magnetic labels decreases the binding affinity of the antigen antibody interaction and the antibody binding capacity (ABC). A scale up model was then proposed, and experimentally verified on larger scale immunological labeling. This model assists in other projects in our lab focused on the efficient magnetic cell sorting at large scale. Restricted by high autofluorescence levels, alveolar macrophages, are difficult to analyze using flow cytometry. Immunomagnetically based CTV system was studied to evaluate if CTV can be used as an alternative of flow cytometry on quantitative cellular receptor study. A good agreement between CTV and FCM was found when monocytes were studied. CTV was then successfully used to analyze AM cells for basal receptor expression, and the expression kinetics when LPS was used for activation. CTV was used to determine if proteins can be immunomagnetically separated via the use of colloidal labels or molecular labels by measuring the magnetism of a labeled protein. Feasibility of the separation process was determined by calculating the retention ratio. It was shown that proteins can be separated immunomagnetically with the use of colloidal labels, such as DM beads, but not with the use of molecular labels used in the study, ferritin. Immunomagnetic cell separation was also successfully applied to separate Bacillus cereus spores from food.","abstract_has_math":false,"creators":["Zhang, Huading"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Chalmers, Jeff"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-11-27T04:32:15Z","subjects":["Engineering, Chemical","MAGNETOPHORETIC","MAGNETOPHORETIC MOBILITY","magnetic","microspheres","CTV","CELL","CELL SEPARATION"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1099068680","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1099068680","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1099068680","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1099068680","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chalmers, Jeff"]},{"key":"dc:creator","label":"Author","values":["Zhang, Huading"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Chemical","MAGNETOPHORETIC","MAGNETOPHORETIC MOBILITY","magnetic","microspheres","CTV","CELL","CELL SEPARATION"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1099068680"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this study, the theoretical model for magnetophoretic mobility was further developed to include the contribution of intrinsic properties of particles or cells and the influence of the properties of the suspending fluid. Using these improvements, the dependence of the magnetophoretic mobility of unlabeled cells/microspheres and cells/microspheres labeled with colloidal magnetic labels on suspending fluid was used to determine the magnetic susceptibility of cells/microspheres and colloidal labels. The combination of these theoretical improvements, and the experimental studies, makes the methodology developed a universal characterization method. To explain the dependence of magnetophoretic mobility or fluorescence intensity on concentrations of the affinity labels, a binding model was proposed. Good agreement was found for lymphocytes labeled with anti CD3 antibody conjugates and the model. The data indicated that the conjugation of larger magnetic labels decreases the binding affinity of the antigen antibody interaction and the antibody binding capacity (ABC). A scale up model was then proposed, and experimentally verified on larger scale immunological labeling. This model assists in other projects in our lab focused on the efficient magnetic cell sorting at large scale. Restricted by high autofluorescence levels, alveolar macrophages, are difficult to analyze using flow cytometry. Immunomagnetically based CTV system was studied to evaluate if CTV can be used as an alternative of flow cytometry on quantitative cellular receptor study. A good agreement between CTV and FCM was found when monocytes were studied. CTV was then successfully used to analyze AM cells for basal receptor expression, and the expression kinetics when LPS was used for activation. CTV was used to determine if proteins can be immunomagnetically separated via the use of colloidal labels or molecular labels by measuring the magnetism of a labeled protein. Feasibility of the separation process was determined by calculating the retention ratio. It was shown that proteins can be separated immunomagnetically with the use of colloidal labels, such as DM beads, but not with the use of molecular labels used in the study, ferritin. Immunomagnetic cell separation was also successfully applied to separate Bacillus cereus spores from food."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.218","2.19 MB"]},{"key":"dc:title","label":"Title","values":["Immunomagnetic cell separation: continued development of fundamental model of magnetophoretic mobility and further applications"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chalmers, Jeff"],"dc:creator":["Zhang, Huading"],"dc:date":["2004"],"dc:description":["In this study, the theoretical model for magnetophoretic mobility was further developed to include the contribution of intrinsic properties of particles or cells and the influence of the properties of the suspending fluid. Using these improvements, the dependence of the magnetophoretic mobility of unlabeled cells/microspheres and cells/microspheres labeled with colloidal magnetic labels on suspending fluid was used to determine the magnetic susceptibility of cells/microspheres and colloidal labels. The combination of these theoretical improvements, and the experimental studies, makes the methodology developed a universal characterization method. To explain the dependence of magnetophoretic mobility or fluorescence intensity on concentrations of the affinity labels, a binding model was proposed. Good agreement was found for lymphocytes labeled with anti CD3 antibody conjugates and the model. The data indicated that the conjugation of larger magnetic labels decreases the binding affinity of the antigen antibody interaction and the antibody binding capacity (ABC). A scale up model was then proposed, and experimentally verified on larger scale immunological labeling. This model assists in other projects in our lab focused on the efficient magnetic cell sorting at large scale. Restricted by high autofluorescence levels, alveolar macrophages, are difficult to analyze using flow cytometry. Immunomagnetically based CTV system was studied to evaluate if CTV can be used as an alternative of flow cytometry on quantitative cellular receptor study. A good agreement between CTV and FCM was found when monocytes were studied. CTV was then successfully used to analyze AM cells for basal receptor expression, and the expression kinetics when LPS was used for activation. CTV was used to determine if proteins can be immunomagnetically separated via the use of colloidal labels or molecular labels by measuring the magnetism of a labeled protein. Feasibility of the separation process was determined by calculating the retention ratio. It was shown that proteins can be separated immunomagnetically with the use of colloidal labels, such as DM beads, but not with the use of molecular labels used in the study, ferritin. Immunomagnetic cell separation was also successfully applied to separate Bacillus cereus spores from food."],"dc:format":["application/pdf","p.218","2.19 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1099068680"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Chemical","MAGNETOPHORETIC","MAGNETOPHORETIC MOBILITY","magnetic","microspheres","CTV","CELL","CELL SEPARATION"],"dc:title":["Immunomagnetic cell separation: continued development of fundamental model of magnetophoretic mobility and further applications"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:32:15Z"}