{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1099343059"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1099343059","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Fracture characteristics, hardness, and grain size of five polycrystalline alumina orthodontic brackets","abstract":"While polycrystalline alumina ceramic brackets have superior esthetics compared to stainless steel brackets, there is concert about fracture of these ceramic brackets during clinical manipulation and debonding. The purpose of this study was to investigate the fracture characteristics and related properties of five currently marketed alumina maxillary central incisor brackets (0.018 x 0.022 inch slot width). The following products were selected: Clarity (Unitek/3M), Allure NSB (GAC), Intrigue (Lancer), Contour (Class One) and MXi (TP). Five samples of each bracket were resin-mounted, and the bases were polished using diamond abrasives. Vickers indentations were made on the bases, using a 1 kg load, to measure the hardness and determine the fracture toughness. Three sample brackets of each brand were notched with a diamond disk and fractured to reveal the bulk microstructure. In addition, another sample of each brand was left in the as-received condition for examination of the bracket design...","abstract_html":"While polycrystalline alumina ceramic brackets have superior esthetics compared to stainless steel brackets, there is concert about fracture of these ceramic brackets during clinical manipulation and debonding. The purpose of this study was to investigate the fracture characteristics and related properties of five currently marketed alumina maxillary central incisor brackets (0.018 x 0.022 inch slot width). The following products were selected: Clarity (Unitek/3M), Allure NSB (GAC), Intrigue (Lancer), Contour (Class One) and MXi (TP). Five samples of each bracket were resin-mounted, and the bases were polished using diamond abrasives. Vickers indentations were made on the bases, using a 1 kg load, to measure the hardness and determine the fracture toughness. Three sample brackets of each brand were notched with a diamond disk and fractured to reveal the bulk microstructure. In addition, another sample of each brand was left in the as-received condition for examination of the bracket design...","abstract_has_math":false,"creators":["Pham, Giao Robert Ngoc"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":[],"advisors":["Brantley, William"],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999","date_published":"1999","updated_at":"2026-11-27T04:32:15Z","subjects":[],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1099343059","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1099343059","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1099343059","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1099343059","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brantley, William"]},{"key":"dc:creator","label":"Author","values":["Pham, Giao Robert Ngoc"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1999"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1099343059"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["While polycrystalline alumina ceramic brackets have superior esthetics compared to stainless steel brackets, there is concert about fracture of these ceramic brackets during clinical manipulation and debonding. The purpose of this study was to investigate the fracture characteristics and related properties of five currently marketed alumina maxillary central incisor brackets (0.018 x 0.022 inch slot width). The following products were selected: Clarity (Unitek/3M), Allure NSB (GAC), Intrigue (Lancer), Contour (Class One) and MXi (TP). Five samples of each bracket were resin-mounted, and the bases were polished using diamond abrasives. Vickers indentations were made on the bases, using a 1 kg load, to measure the hardness and determine the fracture toughness. Three sample brackets of each brand were notched with a diamond disk and fractured to reveal the bulk microstructure. In addition, another sample of each brand was left in the as-received condition for examination of the bracket design..."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.47","1.73 MB"]},{"key":"dc:title","label":"Title","values":["Fracture characteristics, hardness, and grain size of five polycrystalline alumina orthodontic brackets"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brantley, William"],"dc:creator":["Pham, Giao Robert Ngoc"],"dc:date":["1999"],"dc:description":["While polycrystalline alumina ceramic brackets have superior esthetics compared to stainless steel brackets, there is concert about fracture of these ceramic brackets during clinical manipulation and debonding. The purpose of this study was to investigate the fracture characteristics and related properties of five currently marketed alumina maxillary central incisor brackets (0.018 x 0.022 inch slot width). The following products were selected: Clarity (Unitek/3M), Allure NSB (GAC), Intrigue (Lancer), Contour (Class One) and MXi (TP). Five samples of each bracket were resin-mounted, and the bases were polished using diamond abrasives. Vickers indentations were made on the bases, using a 1 kg load, to measure the hardness and determine the fracture toughness. Three sample brackets of each brand were notched with a diamond disk and fractured to reveal the bulk microstructure. In addition, another sample of each brand was left in the as-received condition for examination of the bracket design..."],"dc:format":["application/pdf","p.47","1.73 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1099343059"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:title":["Fracture characteristics, hardness, and grain size of five polycrystalline alumina orthodontic brackets"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:32:15Z"}