{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1133285376"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1133285376","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Chromium-free consumable for welding stainless steel: corrosion perspective","abstract":"Arc welding of stainless steels generates welding fumes containing carcinogenic hexavalent chromium. To mitigate this problem, a Cr-free filler metal needs to be developed to reduce the health risks for welding stainless steel. Ni-Cu alloy, Monel K400, was selected initially based on its galvanic compatibility with types 304 and 316 SS in chloride environments Type 304L (UNS S30403) stainless steel plate was successfully welded with Monel filler wire, resulting in high quality welds with no cracks. The welds survived long term exposure in 0.1 M NaCl with no evidence of corrosion. However, segregated regions in weld that are rich in Cu are the weak spots for corrosion susceptibility. The effects of alloying elements on the corrosion properties of Ni-Cu alloy were investigated to optimize the composition of a Cr-free consumable for welding of stainless steels. Cyclic polarization experiments were performed in 0.1 M NaCl on Ni-base alloys containing different amounts of Cu, Pd, Mo, Fe, and Cr. The localized corrosion behavior improved as the Cu content decreased from 30 to 5 wt%. The addition of 1 wt% Pd ennobled the alloy and greatly improved the localized corrosion properties. The optimized composition is a Ni-based alloy containing 5-10 wt% Cu and 1 wt% Pd. Ni-10Cu-1Pd alloy across the entire dilution range exhibited higher repassivation potential than Type 304L stainless steel in 0.1 M NaCl solution. The repassivation potential was also higher in aerated solutions with chloride concentrations of 105 through 35000 ppm. The breakdown behavior of Bead-On-Plate weld was similar to that of Type 308L welds. After 31 days exposure of samples with crevice-formers in 500 and 1000 ppm chloride solutions, the Bead-On-Plate weld showed much shallower attack than the 308L weld. The passive film on Ni-10Cu-1Pd alloy mainly consisted of outer Ni-hydroxide and inner oxide, but the noble elements of Pd and Cu did not contribute to the formation of the passive film. However, Pd catalyzed the reduction of Cu at the bottom of the artificial pit, which enhanced the cathodic reaction and thus ennobled the deactivation potential making stable pit growth more difficult.","abstract_html":"Arc welding of stainless steels generates welding fumes containing carcinogenic hexavalent chromium. To mitigate this problem, a Cr-free filler metal needs to be developed to reduce the health risks for welding stainless steel. Ni-Cu alloy, Monel K400, was selected initially based on its galvanic compatibility with types 304 and 316 SS in chloride environments Type 304L (UNS S30403) stainless steel plate was successfully welded with Monel filler wire, resulting in high quality welds with no cracks. The welds survived long term exposure in 0.1 M NaCl with no evidence of corrosion. However, segregated regions in weld that are rich in Cu are the weak spots for corrosion susceptibility. The effects of alloying elements on the corrosion properties of Ni-Cu alloy were investigated to optimize the composition of a Cr-free consumable for welding of stainless steels. Cyclic polarization experiments were performed in 0.1 M NaCl on Ni-base alloys containing different amounts of Cu, Pd, Mo, Fe, and Cr. The localized corrosion behavior improved as the Cu content decreased from 30 to 5 wt%. The addition of 1 wt% Pd ennobled the alloy and greatly improved the localized corrosion properties. The optimized composition is a Ni-based alloy containing 5-10 wt% Cu and 1 wt% Pd. Ni-10Cu-1Pd alloy across the entire dilution range exhibited higher repassivation potential than Type 304L stainless steel in 0.1 M NaCl solution. The repassivation potential was also higher in aerated solutions with chloride concentrations of 105 through 35000 ppm. The breakdown behavior of Bead-On-Plate weld was similar to that of Type 308L welds. After 31 days exposure of samples with crevice-formers in 500 and 1000 ppm chloride solutions, the Bead-On-Plate weld showed much shallower attack than the 308L weld. The passive film on Ni-10Cu-1Pd alloy mainly consisted of outer Ni-hydroxide and inner oxide, but the noble elements of Pd and Cu did not contribute to the formation of the passive film. However, Pd catalyzed the reduction of Cu at the bottom of the artificial pit, which enhanced the cathodic reaction and thus ennobled the deactivation potential making stable pit growth more difficult.","abstract_has_math":false,"creators":["Kim, Yeong Ho"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Frankel, Gerald"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-12-02","date_published":"2005-12-02","updated_at":"2026-11-27T04:33:02Z","subjects":["Engineering, Materials Science","stainless steel","corrosion","weld","hexavalent chromium","nickel","alloy","copper","palladium","molybdenum","dilution","segregation","localized corrosion","breakdown","artificial pit electrode","repassivation","deactivation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1133285376","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1133285376","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1133285376","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1133285376","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Frankel, Gerald"]},{"key":"dc:creator","label":"Author","values":["Kim, Yeong Ho"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-12-02"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Materials Science","stainless steel","corrosion","weld","hexavalent chromium","nickel","alloy","copper","palladium","molybdenum","dilution","segregation","localized corrosion","breakdown","artificial pit electrode","repassivation","deactivation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1133285376"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Arc welding of stainless steels generates welding fumes containing carcinogenic hexavalent chromium. To mitigate this problem, a Cr-free filler metal needs to be developed to reduce the health risks for welding stainless steel. Ni-Cu alloy, Monel K400, was selected initially based on its galvanic compatibility with types 304 and 316 SS in chloride environments Type 304L (UNS S30403) stainless steel plate was successfully welded with Monel filler wire, resulting in high quality welds with no cracks. The welds survived long term exposure in 0.1 M NaCl with no evidence of corrosion. However, segregated regions in weld that are rich in Cu are the weak spots for corrosion susceptibility. The effects of alloying elements on the corrosion properties of Ni-Cu alloy were investigated to optimize the composition of a Cr-free consumable for welding of stainless steels. Cyclic polarization experiments were performed in 0.1 M NaCl on Ni-base alloys containing different amounts of Cu, Pd, Mo, Fe, and Cr. The localized corrosion behavior improved as the Cu content decreased from 30 to 5 wt%. The addition of 1 wt% Pd ennobled the alloy and greatly improved the localized corrosion properties. The optimized composition is a Ni-based alloy containing 5-10 wt% Cu and 1 wt% Pd. Ni-10Cu-1Pd alloy across the entire dilution range exhibited higher repassivation potential than Type 304L stainless steel in 0.1 M NaCl solution. The repassivation potential was also higher in aerated solutions with chloride concentrations of 105 through 35000 ppm. The breakdown behavior of Bead-On-Plate weld was similar to that of Type 308L welds. After 31 days exposure of samples with crevice-formers in 500 and 1000 ppm chloride solutions, the Bead-On-Plate weld showed much shallower attack than the 308L weld. The passive film on Ni-10Cu-1Pd alloy mainly consisted of outer Ni-hydroxide and inner oxide, but the noble elements of Pd and Cu did not contribute to the formation of the passive film. However, Pd catalyzed the reduction of Cu at the bottom of the artificial pit, which enhanced the cathodic reaction and thus ennobled the deactivation potential making stable pit growth more difficult."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.220","3.63 MB"]},{"key":"dc:title","label":"Title","values":["Chromium-free consumable for welding stainless steel: corrosion perspective"]}]}],"canonical_facts":{"dc:contributor.advisor":["Frankel, Gerald"],"dc:creator":["Kim, Yeong Ho"],"dc:date":["2005-12-02"],"dc:description":["Arc welding of stainless steels generates welding fumes containing carcinogenic hexavalent chromium. To mitigate this problem, a Cr-free filler metal needs to be developed to reduce the health risks for welding stainless steel. Ni-Cu alloy, Monel K400, was selected initially based on its galvanic compatibility with types 304 and 316 SS in chloride environments Type 304L (UNS S30403) stainless steel plate was successfully welded with Monel filler wire, resulting in high quality welds with no cracks. The welds survived long term exposure in 0.1 M NaCl with no evidence of corrosion. However, segregated regions in weld that are rich in Cu are the weak spots for corrosion susceptibility. The effects of alloying elements on the corrosion properties of Ni-Cu alloy were investigated to optimize the composition of a Cr-free consumable for welding of stainless steels. Cyclic polarization experiments were performed in 0.1 M NaCl on Ni-base alloys containing different amounts of Cu, Pd, Mo, Fe, and Cr. The localized corrosion behavior improved as the Cu content decreased from 30 to 5 wt%. The addition of 1 wt% Pd ennobled the alloy and greatly improved the localized corrosion properties. The optimized composition is a Ni-based alloy containing 5-10 wt% Cu and 1 wt% Pd. Ni-10Cu-1Pd alloy across the entire dilution range exhibited higher repassivation potential than Type 304L stainless steel in 0.1 M NaCl solution. The repassivation potential was also higher in aerated solutions with chloride concentrations of 105 through 35000 ppm. The breakdown behavior of Bead-On-Plate weld was similar to that of Type 308L welds. After 31 days exposure of samples with crevice-formers in 500 and 1000 ppm chloride solutions, the Bead-On-Plate weld showed much shallower attack than the 308L weld. The passive film on Ni-10Cu-1Pd alloy mainly consisted of outer Ni-hydroxide and inner oxide, but the noble elements of Pd and Cu did not contribute to the formation of the passive film. However, Pd catalyzed the reduction of Cu at the bottom of the artificial pit, which enhanced the cathodic reaction and thus ennobled the deactivation potential making stable pit growth more difficult."],"dc:format":["application/pdf","p.220","3.63 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1133285376"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Materials Science","stainless steel","corrosion","weld","hexavalent chromium","nickel","alloy","copper","palladium","molybdenum","dilution","segregation","localized corrosion","breakdown","artificial pit electrode","repassivation","deactivation"],"dc:title":["Chromium-free consumable for welding stainless steel: corrosion perspective"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:33:02Z"}