{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1154710169"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1154710169","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Interactive, quantitative 3D stress echocardiography and myocardial perfusion spect for improved diagnosis of coronary artery disease","abstract":"Coronary artery disease (CAD), which involves narrowing of the vessels supplying blood to the heart, is the leading cause of death in the United States. Stress testing is a common approach for diagnosing myocardial ischemia, a state of blood supply-demand imbalance resulting from CAD. Physical exercise or pharmacologic agents raise the heart’s oxygen demand, failure to meet which sets in myocardial ischemia leading to left ventricular (LV) dysfunction. Stress echocardiography (echo) and stress single photon emission computed tomography (SPECT), which provide complementary anatomical and perfusion information about the heart, remain the two most commonly prescribed cardiac stress testing procedures. Stress echo manifests the LV dysfunction as abnormal myocardial wall motion and thickening, whereas stress SPECT shows the myocardial perfusion defects. However, these two procedures remain limited in their sensitivity and specificity. This dissertation utilizes real-time three-dimensional (RT-3D) ultrasound - an emerging innovation in ultrasound imaging, and focuses on development of automatic image analysis techniques that will increase the diagnostic accuracy of cardiac stress testing using echo and SPECT. The first hypothesis in this dissertation is that a truly quantitative 3D stress echo procedure, that utilizes advanced quantitative image analysis techniques together with RT-3D ultrasound, is capable of overcoming many of the limitations of conventional stress echo and therefore improving diagnostic accuracy. The current research involves the development of a novel interactive and quantitative stress echo software that combines, for the first time, fully automatic tools for accurate pre-/post-stress image alignment, LV myocardial segmentation and quantification of global and regional left ventricular (LV) function for RT-3D echo images. The second hypothesis states that simultaneous improvement in sensitivity and specificity for detecting CAD can be achieved with a multimodality stress testing approach, wherein diagnosis is based on accurately correlated (temporally and spatially) complementary functional and perfusion information available from RT-3D echo and SPECT, respectively. This dissertation includes development of techniques, including a novel elastic image registration algorithm and quantitative analysis techniques, for automatic multimodality analysis of RT-3D echo and SPECT images. Preliminary validation studies have been described that evaluate the feasibility and effectiveness of the novel procedures for diagnosis of CAD.","abstract_html":"Coronary artery disease (CAD), which involves narrowing of the vessels supplying blood to the heart, is the leading cause of death in the United States. Stress testing is a common approach for diagnosing myocardial ischemia, a state of blood supply-demand imbalance resulting from CAD. Physical exercise or pharmacologic agents raise the heart’s oxygen demand, failure to meet which sets in myocardial ischemia leading to left ventricular (LV) dysfunction. Stress echocardiography (echo) and stress single photon emission computed tomography (SPECT), which provide complementary anatomical and perfusion information about the heart, remain the two most commonly prescribed cardiac stress testing procedures. Stress echo manifests the LV dysfunction as abnormal myocardial wall motion and thickening, whereas stress SPECT shows the myocardial perfusion defects. However, these two procedures remain limited in their sensitivity and specificity. This dissertation utilizes real-time three-dimensional (RT-3D) ultrasound - an emerging innovation in ultrasound imaging, and focuses on development of automatic image analysis techniques that will increase the diagnostic accuracy of cardiac stress testing using echo and SPECT. The first hypothesis in this dissertation is that a truly quantitative 3D stress echo procedure, that utilizes advanced quantitative image analysis techniques together with RT-3D ultrasound, is capable of overcoming many of the limitations of conventional stress echo and therefore improving diagnostic accuracy. The current research involves the development of a novel interactive and quantitative stress echo software that combines, for the first time, fully automatic tools for accurate pre-/post-stress image alignment, LV myocardial segmentation and quantification of global and regional left ventricular (LV) function for RT-3D echo images. The second hypothesis states that simultaneous improvement in sensitivity and specificity for detecting CAD can be achieved with a multimodality stress testing approach, wherein diagnosis is based on accurately correlated (temporally and spatially) complementary functional and perfusion information available from RT-3D echo and SPECT, respectively. This dissertation includes development of techniques, including a novel elastic image registration algorithm and quantitative analysis techniques, for automatic multimodality analysis of RT-3D echo and SPECT images. Preliminary validation studies have been described that evaluate the feasibility and effectiveness of the novel procedures for diagnosis of CAD.","abstract_has_math":false,"creators":["Walimbe, Vivek S."],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Roberts, Cynthia"],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-09-20","date_published":"2006-09-20","updated_at":"2026-11-27T04:33:11Z","subjects":["Engineering, Biomedical","stress echocardiography","myocardial perfusion SPECT","real-time 3D echocardiography","coronary artery disease","elastic image registration","segmentation","interactive image analysis","quantitative image analysis"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1154710169","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1154710169","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1154710169","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1154710169","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roberts, Cynthia"]},{"key":"dc:creator","label":"Author","values":["Walimbe, Vivek S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-09-20"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","stress echocardiography","myocardial perfusion SPECT","real-time 3D echocardiography","coronary artery disease","elastic image registration","segmentation","interactive image analysis","quantitative image analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1154710169"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Coronary artery disease (CAD), which involves narrowing of the vessels supplying blood to the heart, is the leading cause of death in the United States. Stress testing is a common approach for diagnosing myocardial ischemia, a state of blood supply-demand imbalance resulting from CAD. Physical exercise or pharmacologic agents raise the heart’s oxygen demand, failure to meet which sets in myocardial ischemia leading to left ventricular (LV) dysfunction. Stress echocardiography (echo) and stress single photon emission computed tomography (SPECT), which provide complementary anatomical and perfusion information about the heart, remain the two most commonly prescribed cardiac stress testing procedures. Stress echo manifests the LV dysfunction as abnormal myocardial wall motion and thickening, whereas stress SPECT shows the myocardial perfusion defects. However, these two procedures remain limited in their sensitivity and specificity. This dissertation utilizes real-time three-dimensional (RT-3D) ultrasound - an emerging innovation in ultrasound imaging, and focuses on development of automatic image analysis techniques that will increase the diagnostic accuracy of cardiac stress testing using echo and SPECT. The first hypothesis in this dissertation is that a truly quantitative 3D stress echo procedure, that utilizes advanced quantitative image analysis techniques together with RT-3D ultrasound, is capable of overcoming many of the limitations of conventional stress echo and therefore improving diagnostic accuracy. The current research involves the development of a novel interactive and quantitative stress echo software that combines, for the first time, fully automatic tools for accurate pre-/post-stress image alignment, LV myocardial segmentation and quantification of global and regional left ventricular (LV) function for RT-3D echo images. The second hypothesis states that simultaneous improvement in sensitivity and specificity for detecting CAD can be achieved with a multimodality stress testing approach, wherein diagnosis is based on accurately correlated (temporally and spatially) complementary functional and perfusion information available from RT-3D echo and SPECT, respectively. This dissertation includes development of techniques, including a novel elastic image registration algorithm and quantitative analysis techniques, for automatic multimodality analysis of RT-3D echo and SPECT images. Preliminary validation studies have been described that evaluate the feasibility and effectiveness of the novel procedures for diagnosis of CAD."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.48 MB"]},{"key":"dc:title","label":"Title","values":["Interactive, quantitative 3D stress echocardiography and myocardial perfusion spect for improved diagnosis of coronary artery disease"]}]}],"canonical_facts":{"dc:contributor.advisor":["Roberts, Cynthia"],"dc:creator":["Walimbe, Vivek S."],"dc:date":["2006-09-20"],"dc:description":["Coronary artery disease (CAD), which involves narrowing of the vessels supplying blood to the heart, is the leading cause of death in the United States. Stress testing is a common approach for diagnosing myocardial ischemia, a state of blood supply-demand imbalance resulting from CAD. Physical exercise or pharmacologic agents raise the heart’s oxygen demand, failure to meet which sets in myocardial ischemia leading to left ventricular (LV) dysfunction. Stress echocardiography (echo) and stress single photon emission computed tomography (SPECT), which provide complementary anatomical and perfusion information about the heart, remain the two most commonly prescribed cardiac stress testing procedures. Stress echo manifests the LV dysfunction as abnormal myocardial wall motion and thickening, whereas stress SPECT shows the myocardial perfusion defects. However, these two procedures remain limited in their sensitivity and specificity. This dissertation utilizes real-time three-dimensional (RT-3D) ultrasound - an emerging innovation in ultrasound imaging, and focuses on development of automatic image analysis techniques that will increase the diagnostic accuracy of cardiac stress testing using echo and SPECT. The first hypothesis in this dissertation is that a truly quantitative 3D stress echo procedure, that utilizes advanced quantitative image analysis techniques together with RT-3D ultrasound, is capable of overcoming many of the limitations of conventional stress echo and therefore improving diagnostic accuracy. The current research involves the development of a novel interactive and quantitative stress echo software that combines, for the first time, fully automatic tools for accurate pre-/post-stress image alignment, LV myocardial segmentation and quantification of global and regional left ventricular (LV) function for RT-3D echo images. The second hypothesis states that simultaneous improvement in sensitivity and specificity for detecting CAD can be achieved with a multimodality stress testing approach, wherein diagnosis is based on accurately correlated (temporally and spatially) complementary functional and perfusion information available from RT-3D echo and SPECT, respectively. This dissertation includes development of techniques, including a novel elastic image registration algorithm and quantitative analysis techniques, for automatic multimodality analysis of RT-3D echo and SPECT images. Preliminary validation studies have been described that evaluate the feasibility and effectiveness of the novel procedures for diagnosis of CAD."],"dc:format":["application/pdf","2.48 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1154710169"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","stress echocardiography","myocardial perfusion SPECT","real-time 3D echocardiography","coronary artery disease","elastic image registration","segmentation","interactive image analysis","quantitative image analysis"],"dc:title":["Interactive, quantitative 3D stress echocardiography and myocardial perfusion spect for improved diagnosis of coronary artery disease"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:33:11Z"}