{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1211920104"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1211920104","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF THE IN VIVO HUMAN CORNEA","abstract":"The goal of the research is to investigate corneal hysteresis as measured by the Reichert Ocular Response Analyzer (ORA) and to develop new methods for evaluating the biomechanical properties of the human cornea through the analysis of its deformation in response to an air pulse from the ORA. A mathematical model was developed to simulate the viscoelastic behavior of the cornea during an ORA measurement. The model was validated by comparing the strain behavior of the model to that of a corneal phantom using high speed photography. The model was used to investigate the effects of changes to elasticity or viscosity on hysteresis. High speed photography was used to evaluate and compare the size and symmetry of the corneal deformations between normal corneas and those with keratoconus. The model and high speed photography were used to measure the viscosity and elasticity of the in vivo human. The model utilizes the values for the air pressure applied to the cornea by the ORA, the deformation recorded with the high speed photography to calculate viscosity and elasticity. The high speed photography revealed that the deformation area of keratoconic corneas is smaller than normals and the area correlates with features of the ORA signal. The results for the elasticity and viscosity of normal and glaucomatous corneas were compared, and it was found that the elasticity of glaucomatous corneas is higher than normal corneas. The ability to evaluate in vivo biomechanical properties of the human cornea may useful in differentiating disease states and evaluating response to surgical interventions.","abstract_html":"The goal of the research is to investigate corneal hysteresis as measured by the Reichert Ocular Response Analyzer (ORA) and to develop new methods for evaluating the biomechanical properties of the human cornea through the analysis of its deformation in response to an air pulse from the ORA. A mathematical model was developed to simulate the viscoelastic behavior of the cornea during an ORA measurement. The model was validated by comparing the strain behavior of the model to that of a corneal phantom using high speed photography. The model was used to investigate the effects of changes to elasticity or viscosity on hysteresis. High speed photography was used to evaluate and compare the size and symmetry of the corneal deformations between normal corneas and those with keratoconus. The model and high speed photography were used to measure the viscosity and elasticity of the in vivo human. The model utilizes the values for the air pressure applied to the cornea by the ORA, the deformation recorded with the high speed photography to calculate viscosity and elasticity. The high speed photography revealed that the deformation area of keratoconic corneas is smaller than normals and the area correlates with features of the ORA signal. The results for the elasticity and viscosity of normal and glaucomatous corneas were compared, and it was found that the elasticity of glaucomatous corneas is higher than normal corneas. The ability to evaluate in vivo biomechanical properties of the human cornea may useful in differentiating disease states and evaluating response to surgical interventions.","abstract_has_math":false,"creators":["Glass, Dianne Henry"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Roberts, Cynthia J."],"committee_members":[],"year":2008,"date_issued":"2008-06-24","date_published":"2008-06-24","updated_at":"2026-11-27T04:33:48Z","subjects":["Accounting","Biomedical Research","Engineering","Mechanics","Ophthalmology","cornea","biomechanics","elasticity","viscosity","viscoelasticity","hysteresis","keratoconus","glaucoma"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1211920104","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1211920104","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1211920104","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1211920104","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Roberts, Cynthia J."]},{"key":"dc:creator","label":"Author","values":["Glass, Dianne Henry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-06-24"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Accounting","Biomedical Research","Engineering","Mechanics","Ophthalmology","cornea","biomechanics","elasticity","viscosity","viscoelasticity","hysteresis","keratoconus","glaucoma"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1211920104"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The goal of the research is to investigate corneal hysteresis as measured by the Reichert Ocular Response Analyzer (ORA) and to develop new methods for evaluating the biomechanical properties of the human cornea through the analysis of its deformation in response to an air pulse from the ORA. A mathematical model was developed to simulate the viscoelastic behavior of the cornea during an ORA measurement. The model was validated by comparing the strain behavior of the model to that of a corneal phantom using high speed photography. The model was used to investigate the effects of changes to elasticity or viscosity on hysteresis. High speed photography was used to evaluate and compare the size and symmetry of the corneal deformations between normal corneas and those with keratoconus. The model and high speed photography were used to measure the viscosity and elasticity of the in vivo human. The model utilizes the values for the air pressure applied to the cornea by the ORA, the deformation recorded with the high speed photography to calculate viscosity and elasticity. The high speed photography revealed that the deformation area of keratoconic corneas is smaller than normals and the area correlates with features of the ORA signal. The results for the elasticity and viscosity of normal and glaucomatous corneas were compared, and it was found that the elasticity of glaucomatous corneas is higher than normal corneas. The ability to evaluate in vivo biomechanical properties of the human cornea may useful in differentiating disease states and evaluating response to surgical interventions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.72","2.87 MB"]},{"key":"dc:title","label":"Title","values":["CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF THE IN VIVO HUMAN CORNEA"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Roberts, Cynthia J."],"dc:creator":["Glass, Dianne Henry"],"dc:date":["2008-06-24"],"dc:description":["The goal of the research is to investigate corneal hysteresis as measured by the Reichert Ocular Response Analyzer (ORA) and to develop new methods for evaluating the biomechanical properties of the human cornea through the analysis of its deformation in response to an air pulse from the ORA. A mathematical model was developed to simulate the viscoelastic behavior of the cornea during an ORA measurement. The model was validated by comparing the strain behavior of the model to that of a corneal phantom using high speed photography. The model was used to investigate the effects of changes to elasticity or viscosity on hysteresis. High speed photography was used to evaluate and compare the size and symmetry of the corneal deformations between normal corneas and those with keratoconus. The model and high speed photography were used to measure the viscosity and elasticity of the in vivo human. The model utilizes the values for the air pressure applied to the cornea by the ORA, the deformation recorded with the high speed photography to calculate viscosity and elasticity. The high speed photography revealed that the deformation area of keratoconic corneas is smaller than normals and the area correlates with features of the ORA signal. The results for the elasticity and viscosity of normal and glaucomatous corneas were compared, and it was found that the elasticity of glaucomatous corneas is higher than normal corneas. The ability to evaluate in vivo biomechanical properties of the human cornea may useful in differentiating disease states and evaluating response to surgical interventions."],"dc:format":["application/pdf","p.72","2.87 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1211920104"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Accounting","Biomedical Research","Engineering","Mechanics","Ophthalmology","cornea","biomechanics","elasticity","viscosity","viscoelasticity","hysteresis","keratoconus","glaucoma"],"dc:title":["CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF THE IN VIVO HUMAN CORNEA"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:33:48Z"}