{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1219938403"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1219938403","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"MRI-Based Attenuation Correction for PET Reconstruction","abstract":"In this study we proposed and developed a simple attenuation mapping approachbased on magnetic resonance imaging (MRI) for the purpose of reconstructing positron emission tomography (PET) images in PET/MRI imaging devices. After experimental development, an in vivo calibration was performed by whole body scanning of five beagles on both a PET/CT and MRI. The attenuation was determined by using an automatic segmentation algorithm to segment regions of air, lung, soft tissue, and bone and assigning them values of 0.002 cm-1, 0.030 cm-1, 0.098 cm-1, and 0.130 cm-1 respectively. The CT attenuated PET images and the MRI attenuated PET images were very similar, and average standardized uptake values (SUV) for mostregions of interest differed by 1% - 6%. Also, mean relative differences (MRD) between the images were between 5% and 9% for most regions. The only exception isbone, where the three region MRI attenuated PET images had an SUV 9% less on average than the CT attenuation images, and the MRD averaged 14%. Also, additionalsegmentation of bone in the four region MRI attenuated PET images reduced the SUV difference to 3% and the MRD to 6%. However, the differences between the CT and 3 region attenuations were much smaller than the differences between CT attenuated and unattenuated PET images, which had average SUVs of 1-37% and MRDs of 10-45%. In particular the spine had an average SUV difference of 29% and MRD of 45%. Therefore, despite the improvements in the four region segmentation, the three region segmentation without delineation of osseous tissues produces high quality images that are sufficient for most expected clinical purposes.","abstract_html":"In this study we proposed and developed a simple attenuation mapping approachbased on magnetic resonance imaging (MRI) for the purpose of reconstructing positron emission tomography (PET) images in PET/MRI imaging devices. After experimental development, an in vivo calibration was performed by whole body scanning of five beagles on both a PET/CT and MRI. The attenuation was determined by using an automatic segmentation algorithm to segment regions of air, lung, soft tissue, and bone and assigning them values of 0.002 cm-1, 0.030 cm-1, 0.098 cm-1, and 0.130 cm-1 respectively. The CT attenuated PET images and the MRI attenuated PET images were very similar, and average standardized uptake values (SUV) for mostregions of interest differed by 1% - 6%. Also, mean relative differences (MRD) between the images were between 5% and 9% for most regions. The only exception isbone, where the three region MRI attenuated PET images had an SUV 9% less on average than the CT attenuation images, and the MRD averaged 14%. Also, additionalsegmentation of bone in the four region MRI attenuated PET images reduced the SUV difference to 3% and the MRD to 6%. However, the differences between the CT and 3 region attenuations were much smaller than the differences between CT attenuated and unattenuated PET images, which had average SUVs of 1-37% and MRDs of 10-45%. In particular the spine had an average SUV difference of 29% and MRD of 45%. Therefore, despite the improvements in the four region segmentation, the three region segmentation without delineation of osseous tissues produces high quality images that are sufficient for most expected clinical purposes.","abstract_has_math":false,"creators":["Steinberg, Jeffrey"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Honscheid, Klaus","Knopp, Michael"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-09-12","date_published":"2008-09-12","updated_at":"2026-11-27T04:33:54Z","subjects":["Radiology","magnetic resonance imaging","positron emission tomography","attenuation correction","segmentation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1219938403","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1219938403","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1219938403","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1219938403","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Honscheid, Klaus","Knopp, Michael"]},{"key":"dc:creator","label":"Author","values":["Steinberg, Jeffrey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-09-12"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiology","magnetic resonance imaging","positron emission tomography","attenuation correction","segmentation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1219938403"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this study we proposed and developed a simple attenuation mapping approachbased on magnetic resonance imaging (MRI) for the purpose of reconstructing positron emission tomography (PET) images in PET/MRI imaging devices. After experimental development, an in vivo calibration was performed by whole body scanning of five beagles on both a PET/CT and MRI. The attenuation was determined by using an automatic segmentation algorithm to segment regions of air, lung, soft tissue, and bone and assigning them values of 0.002 cm-1, 0.030 cm-1, 0.098 cm-1, and 0.130 cm-1 respectively. The CT attenuated PET images and the MRI attenuated PET images were very similar, and average standardized uptake values (SUV) for mostregions of interest differed by 1% - 6%. Also, mean relative differences (MRD) between the images were between 5% and 9% for most regions. The only exception isbone, where the three region MRI attenuated PET images had an SUV 9% less on average than the CT attenuation images, and the MRD averaged 14%. Also, additionalsegmentation of bone in the four region MRI attenuated PET images reduced the SUV difference to 3% and the MRD to 6%. However, the differences between the CT and 3 region attenuations were much smaller than the differences between CT attenuated and unattenuated PET images, which had average SUVs of 1-37% and MRDs of 10-45%. In particular the spine had an average SUV difference of 29% and MRD of 45%. Therefore, despite the improvements in the four region segmentation, the three region segmentation without delineation of osseous tissues produces high quality images that are sufficient for most expected clinical purposes."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.97","2.97 MB"]},{"key":"dc:title","label":"Title","values":["MRI-Based Attenuation Correction for PET Reconstruction"]}]}],"canonical_facts":{"dc:contributor.advisor":["Honscheid, Klaus","Knopp, Michael"],"dc:creator":["Steinberg, Jeffrey"],"dc:date":["2008-09-12"],"dc:description":["In this study we proposed and developed a simple attenuation mapping approachbased on magnetic resonance imaging (MRI) for the purpose of reconstructing positron emission tomography (PET) images in PET/MRI imaging devices. After experimental development, an in vivo calibration was performed by whole body scanning of five beagles on both a PET/CT and MRI. The attenuation was determined by using an automatic segmentation algorithm to segment regions of air, lung, soft tissue, and bone and assigning them values of 0.002 cm-1, 0.030 cm-1, 0.098 cm-1, and 0.130 cm-1 respectively. The CT attenuated PET images and the MRI attenuated PET images were very similar, and average standardized uptake values (SUV) for mostregions of interest differed by 1% - 6%. Also, mean relative differences (MRD) between the images were between 5% and 9% for most regions. The only exception isbone, where the three region MRI attenuated PET images had an SUV 9% less on average than the CT attenuation images, and the MRD averaged 14%. Also, additionalsegmentation of bone in the four region MRI attenuated PET images reduced the SUV difference to 3% and the MRD to 6%. However, the differences between the CT and 3 region attenuations were much smaller than the differences between CT attenuated and unattenuated PET images, which had average SUVs of 1-37% and MRDs of 10-45%. In particular the spine had an average SUV difference of 29% and MRD of 45%. Therefore, despite the improvements in the four region segmentation, the three region segmentation without delineation of osseous tissues produces high quality images that are sufficient for most expected clinical purposes."],"dc:format":["application/pdf","p.97","2.97 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1219938403"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Radiology","magnetic resonance imaging","positron emission tomography","attenuation correction","segmentation"],"dc:title":["MRI-Based Attenuation Correction for PET Reconstruction"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:33:54Z"}