{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1229980146"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1229980146","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Finite Element Model of Shape and Density Adaptation in Engineered Bone","abstract":"A finite element method is combined with control theory and used to model bone’s shape and density adaptations. The model is implemented using Simulink (The MathWorks Inc., Natick, MA) along with functions from MATLAB (The MathWorks Inc., Natick, MA) and COMSOL (COMSOL Inc., Burlington, MA). Regulators of shape and density adaptations are user-definable as a function of time or as a function of a mechanical signal such as strain. The described technique is used to simulate the adaptations in a tissue engineered bone graft, or bone flap. First, the functionality of each of the remodeling rules is demonstrated. Then, shape and density remodeling is combined to replicate the bone flap’s adaptations and compared to experimental data. Finally, the model is used to theorize how the bone flap may behave when reimplanted during a maxilla reconstruction.","abstract_html":"A finite element method is combined with control theory and used to model bone’s shape and density adaptations. The model is implemented using Simulink (The MathWorks Inc., Natick, MA) along with functions from MATLAB (The MathWorks Inc., Natick, MA) and COMSOL (COMSOL Inc., Burlington, MA). Regulators of shape and density adaptations are user-definable as a function of time or as a function of a mechanical signal such as strain. The described technique is used to simulate the adaptations in a tissue engineered bone graft, or bone flap. First, the functionality of each of the remodeling rules is demonstrated. Then, shape and density remodeling is combined to replicate the bone flap’s adaptations and compared to experimental data. Finally, the model is used to theorize how the bone flap may behave when reimplanted during a maxilla reconstruction.","abstract_has_math":false,"creators":["Jansen, Rebecca M."],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Hart, Richard T."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T04:34:02Z","subjects":["Biomedical Research","Engineering","Mechanical Engineering","finite element","bone flap","shape adaptation","density adaptation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1229980146","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1229980146","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1229980146","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1229980146","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hart, Richard T."]},{"key":"dc:creator","label":"Author","values":["Jansen, Rebecca M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Engineering","Mechanical Engineering","finite element","bone flap","shape adaptation","density adaptation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1229980146"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A finite element method is combined with control theory and used to model bone’s shape and density adaptations. The model is implemented using Simulink (The MathWorks Inc., Natick, MA) along with functions from MATLAB (The MathWorks Inc., Natick, MA) and COMSOL (COMSOL Inc., Burlington, MA). Regulators of shape and density adaptations are user-definable as a function of time or as a function of a mechanical signal such as strain. The described technique is used to simulate the adaptations in a tissue engineered bone graft, or bone flap. First, the functionality of each of the remodeling rules is demonstrated. Then, shape and density remodeling is combined to replicate the bone flap’s adaptations and compared to experimental data. Finally, the model is used to theorize how the bone flap may behave when reimplanted during a maxilla reconstruction."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.175","4.89 MB"]},{"key":"dc:title","label":"Title","values":["Finite Element Model of Shape and Density Adaptation in Engineered Bone"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hart, Richard T."],"dc:creator":["Jansen, Rebecca M."],"dc:date":["2008"],"dc:description":["A finite element method is combined with control theory and used to model bone’s shape and density adaptations. The model is implemented using Simulink (The MathWorks Inc., Natick, MA) along with functions from MATLAB (The MathWorks Inc., Natick, MA) and COMSOL (COMSOL Inc., Burlington, MA). Regulators of shape and density adaptations are user-definable as a function of time or as a function of a mechanical signal such as strain. The described technique is used to simulate the adaptations in a tissue engineered bone graft, or bone flap. First, the functionality of each of the remodeling rules is demonstrated. Then, shape and density remodeling is combined to replicate the bone flap’s adaptations and compared to experimental data. Finally, the model is used to theorize how the bone flap may behave when reimplanted during a maxilla reconstruction."],"dc:format":["application/pdf","p.175","4.89 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1229980146"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Engineering","Mechanical Engineering","finite element","bone flap","shape adaptation","density adaptation"],"dc:title":["Finite Element Model of Shape and Density Adaptation in Engineered Bone"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:34:02Z"}