{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1240445960"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1240445960","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Accommodative microfluctuations, crystalline lens tension, ciliary body thickness, and refractive error in children","abstract":"<p>Purpose: To investigate the relationship between microfluctuations in accommodation, resting tension on the crystalline lens, ciliary body thickness, and refractive error in children.</p><p>Methods: Subjects were 49 children, ages eight to 15 years. Subjects wore habitual correction over their left eye and an infrared filter over the right eye during accommodative measurements. Monocular accommodation was measured continuously for two, 30-second periods using a PowerRef I at a sampling rate of 25 Hz while subjects viewed a high-contrast target at 0.25 m. The high (1.0-2.3 Hz) and low (0-0.6 Hz) frequency components of the power spectrum from a Fast Fourier Transform of the accommodative response were used in analysis. Resting tension on the crystalline lens was assessed by measuring the amplitude of the oscillations of the crystalline lens following a rightward 20° saccadic eye movement. Ciliary body thickness was measured two millimeters posterior to the scleral spur from images obtained with a Zeiss Visante™ OCT. Cycloplegic spherical equivalent refractive error was obtained with the Grand Seiko autorefractor.</p><p>Results: The mean ± SD spherical equivalent refractive error was -1.00 D ± 2.25 (range -6.00 D to +3.44 D). Greater power in the high-frequency component of accommodative microfluctuations was associated with thinner ciliary bodies, lower ages and more hyperopic refractive errors. No statistically significant relationship was found for the low-frequency component or root mean square of accommodative microfluctuations and refractive error.</p><p>Conclusions: High-frequency microfluctuations of accommodation appear to be suppressed with thicker ciliary bodies. These variations in accommodation need to be observed in a longitudinal study to better assess the functional significance of their relationship to ciliary body size and refractive error.</p>","abstract_html":"&lt;p&gt;Purpose: To investigate the relationship between microfluctuations in accommodation, resting tension on the crystalline lens, ciliary body thickness, and refractive error in children.&lt;/p&gt;&lt;p&gt;Methods: Subjects were 49 children, ages eight to 15 years. Subjects wore habitual correction over their left eye and an infrared filter over the right eye during accommodative measurements. Monocular accommodation was measured continuously for two, 30-second periods using a PowerRef I at a sampling rate of 25 Hz while subjects viewed a high-contrast target at 0.25 m. The high (1.0-2.3 Hz) and low (0-0.6 Hz) frequency components of the power spectrum from a Fast Fourier Transform of the accommodative response were used in analysis. Resting tension on the crystalline lens was assessed by measuring the amplitude of the oscillations of the crystalline lens following a rightward 20° saccadic eye movement. Ciliary body thickness was measured two millimeters posterior to the scleral spur from images obtained with a Zeiss Visante™ OCT. Cycloplegic spherical equivalent refractive error was obtained with the Grand Seiko autorefractor.&lt;/p&gt;&lt;p&gt;Results: The mean ± SD spherical equivalent refractive error was -1.00 D ± 2.25 (range -6.00 D to +3.44 D). Greater power in the high-frequency component of accommodative microfluctuations was associated with thinner ciliary bodies, lower ages and more hyperopic refractive errors. No statistically significant relationship was found for the low-frequency component or root mean square of accommodative microfluctuations and refractive error.&lt;/p&gt;&lt;p&gt;Conclusions: High-frequency microfluctuations of accommodation appear to be suppressed with thicker ciliary bodies. These variations in accommodation need to be observed in a longitudinal study to better assess the functional significance of their relationship to ciliary body size and refractive error.&lt;/p&gt;","abstract_has_math":false,"creators":["Schultz, Kristin E."],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Vision Science","degree_department":null,"school":null,"contributors":[],"advisors":["Bailey, Melissa"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-06-26","date_published":"2009-06-26","updated_at":"2026-11-27T04:34:08Z","subjects":["Ophthalmology","Optics","myopia","accommodation","crystalline lens","ciliary body","children"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1240445960","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1240445960","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1240445960","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1240445960","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bailey, Melissa"]},{"key":"dc:creator","label":"Author","values":["Schultz, Kristin E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-06-26"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Vision Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ophthalmology","Optics","myopia","accommodation","crystalline lens","ciliary body","children"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1240445960"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Purpose: To investigate the relationship between microfluctuations in accommodation, resting tension on the crystalline lens, ciliary body thickness, and refractive error in children.</p><p>Methods: Subjects were 49 children, ages eight to 15 years. Subjects wore habitual correction over their left eye and an infrared filter over the right eye during accommodative measurements. Monocular accommodation was measured continuously for two, 30-second periods using a PowerRef I at a sampling rate of 25 Hz while subjects viewed a high-contrast target at 0.25 m. The high (1.0-2.3 Hz) and low (0-0.6 Hz) frequency components of the power spectrum from a Fast Fourier Transform of the accommodative response were used in analysis. Resting tension on the crystalline lens was assessed by measuring the amplitude of the oscillations of the crystalline lens following a rightward 20° saccadic eye movement. Ciliary body thickness was measured two millimeters posterior to the scleral spur from images obtained with a Zeiss Visante™ OCT. Cycloplegic spherical equivalent refractive error was obtained with the Grand Seiko autorefractor.</p><p>Results: The mean ± SD spherical equivalent refractive error was -1.00 D ± 2.25 (range -6.00 D to +3.44 D). Greater power in the high-frequency component of accommodative microfluctuations was associated with thinner ciliary bodies, lower ages and more hyperopic refractive errors. No statistically significant relationship was found for the low-frequency component or root mean square of accommodative microfluctuations and refractive error.</p><p>Conclusions: High-frequency microfluctuations of accommodation appear to be suppressed with thicker ciliary bodies. These variations in accommodation need to be observed in a longitudinal study to better assess the functional significance of their relationship to ciliary body size and refractive error.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.75","503.1 KB"]},{"key":"dc:title","label":"Title","values":["Accommodative microfluctuations, crystalline lens tension, ciliary body thickness, and refractive error in children"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bailey, Melissa"],"dc:creator":["Schultz, Kristin E."],"dc:date":["2009-06-26"],"dc:description":["<p>Purpose: To investigate the relationship between microfluctuations in accommodation, resting tension on the crystalline lens, ciliary body thickness, and refractive error in children.</p><p>Methods: Subjects were 49 children, ages eight to 15 years. Subjects wore habitual correction over their left eye and an infrared filter over the right eye during accommodative measurements. Monocular accommodation was measured continuously for two, 30-second periods using a PowerRef I at a sampling rate of 25 Hz while subjects viewed a high-contrast target at 0.25 m. The high (1.0-2.3 Hz) and low (0-0.6 Hz) frequency components of the power spectrum from a Fast Fourier Transform of the accommodative response were used in analysis. Resting tension on the crystalline lens was assessed by measuring the amplitude of the oscillations of the crystalline lens following a rightward 20° saccadic eye movement. Ciliary body thickness was measured two millimeters posterior to the scleral spur from images obtained with a Zeiss Visante™ OCT. Cycloplegic spherical equivalent refractive error was obtained with the Grand Seiko autorefractor.</p><p>Results: The mean ± SD spherical equivalent refractive error was -1.00 D ± 2.25 (range -6.00 D to +3.44 D). Greater power in the high-frequency component of accommodative microfluctuations was associated with thinner ciliary bodies, lower ages and more hyperopic refractive errors. No statistically significant relationship was found for the low-frequency component or root mean square of accommodative microfluctuations and refractive error.</p><p>Conclusions: High-frequency microfluctuations of accommodation appear to be suppressed with thicker ciliary bodies. These variations in accommodation need to be observed in a longitudinal study to better assess the functional significance of their relationship to ciliary body size and refractive error.</p>"],"dc:format":["application/pdf","p.75","503.1 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1240445960"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Ophthalmology","Optics","myopia","accommodation","crystalline lens","ciliary body","children"],"dc:title":["Accommodative microfluctuations, crystalline lens tension, ciliary body thickness, and refractive error in children"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Vision Science"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:34:08Z"}