{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1243628129"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1243628129","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Experimental Evaluation of Reinforcement Methods for Concrete Beam-Column Joints","abstract":"<p>Prefabricated Cage System (PCS), a new method of reinforcement for concrete members, has recently been proposed as an alternative to traditional steel reinforcing bar (rebar) cage reinforcement. PCS involves the fabrication of a reinforcing cage cut from a hollow steel tube. The result is a monolithic reinforcing cage free from tied joints and hooked bars currently found in rebar cages. A criticism of PCS reinforcement to date has been a lack of research demonstrating the ability of the reinforcement to be used in a structural system, in which beams, columns, walls and floor slabs must all frame together and work concurrently to resist loadings. </p><p>Six beam-column joint specimens were constructed and tested under reverse cyclic loading to failure. The six specimens are divided into three groups, each group representing a different joint design. Within each of the three groups are equivalent PCS and rebar reinforced specimens. The overall load and deformation capacities of the PCS joints are compared to those of equivalent rebar joints. The results of the present study show that the PCS joints had a slightly higher strength and significantly greater deformation capacities than the equivalent rebar joints.</p>","abstract_html":"&lt;p&gt;Prefabricated Cage System (PCS), a new method of reinforcement for concrete members, has recently been proposed as an alternative to traditional steel reinforcing bar (rebar) cage reinforcement. PCS involves the fabrication of a reinforcing cage cut from a hollow steel tube. The result is a monolithic reinforcing cage free from tied joints and hooked bars currently found in rebar cages. A criticism of PCS reinforcement to date has been a lack of research demonstrating the ability of the reinforcement to be used in a structural system, in which beams, columns, walls and floor slabs must all frame together and work concurrently to resist loadings. &lt;/p&gt;&lt;p&gt;Six beam-column joint specimens were constructed and tested under reverse cyclic loading to failure. The six specimens are divided into three groups, each group representing a different joint design. Within each of the three groups are equivalent PCS and rebar reinforced specimens. The overall load and deformation capacities of the PCS joints are compared to those of equivalent rebar joints. The results of the present study show that the PCS joints had a slightly higher strength and significantly greater deformation capacities than the equivalent rebar joints.&lt;/p&gt;","abstract_has_math":false,"creators":["Fisher, Matthew John"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sezen, Halil"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-09-03","date_published":"2009-09-03","updated_at":"2026-11-27T04:34:13Z","subjects":["Engineering","Beam-column joints","steel reinforcement","reinforced concrete","shear failure"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1243628129","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1243628129","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1243628129","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1243628129","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sezen, Halil"]},{"key":"dc:creator","label":"Author","values":["Fisher, Matthew John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-09-03"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Beam-column joints","steel reinforcement","reinforced concrete","shear failure"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1243628129"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Prefabricated Cage System (PCS), a new method of reinforcement for concrete members, has recently been proposed as an alternative to traditional steel reinforcing bar (rebar) cage reinforcement. PCS involves the fabrication of a reinforcing cage cut from a hollow steel tube. The result is a monolithic reinforcing cage free from tied joints and hooked bars currently found in rebar cages. A criticism of PCS reinforcement to date has been a lack of research demonstrating the ability of the reinforcement to be used in a structural system, in which beams, columns, walls and floor slabs must all frame together and work concurrently to resist loadings. </p><p>Six beam-column joint specimens were constructed and tested under reverse cyclic loading to failure. The six specimens are divided into three groups, each group representing a different joint design. Within each of the three groups are equivalent PCS and rebar reinforced specimens. The overall load and deformation capacities of the PCS joints are compared to those of equivalent rebar joints. The results of the present study show that the PCS joints had a slightly higher strength and significantly greater deformation capacities than the equivalent rebar joints.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.188","32.72 MB"]},{"key":"dc:title","label":"Title","values":["Experimental Evaluation of Reinforcement Methods for Concrete Beam-Column Joints"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sezen, Halil"],"dc:creator":["Fisher, Matthew John"],"dc:date":["2009-09-03"],"dc:description":["<p>Prefabricated Cage System (PCS), a new method of reinforcement for concrete members, has recently been proposed as an alternative to traditional steel reinforcing bar (rebar) cage reinforcement. PCS involves the fabrication of a reinforcing cage cut from a hollow steel tube. The result is a monolithic reinforcing cage free from tied joints and hooked bars currently found in rebar cages. A criticism of PCS reinforcement to date has been a lack of research demonstrating the ability of the reinforcement to be used in a structural system, in which beams, columns, walls and floor slabs must all frame together and work concurrently to resist loadings. </p><p>Six beam-column joint specimens were constructed and tested under reverse cyclic loading to failure. The six specimens are divided into three groups, each group representing a different joint design. Within each of the three groups are equivalent PCS and rebar reinforced specimens. The overall load and deformation capacities of the PCS joints are compared to those of equivalent rebar joints. The results of the present study show that the PCS joints had a slightly higher strength and significantly greater deformation capacities than the equivalent rebar joints.</p>"],"dc:format":["application/pdf","p.188","32.72 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1243628129"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","Beam-column joints","steel reinforcement","reinforced concrete","shear failure"],"dc:title":["Experimental Evaluation of Reinforcement Methods for Concrete Beam-Column Joints"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:34:13Z"}