{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1243977349"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1243977349","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Effects of Localized Blade Endwall Suction on Surface Heat Transfer","abstract":"Two methods of flow control were designed to mitigate the effects of the horseshoe vortex structure (HV) at an airfoil/endwall junction. An experimental study was conducted in a low-speed wind tunnel to quantify the effects of localized boundary layer removal on surface heat transfer. A transient infrared technique was used to measure theconvective heat transfer values along the surrounding surface. Particle image velocimetry was used to collect the time-mean velocity vectors of the flow field adjacent to the endwall along three planes of interest. Boundary layer suction was applied through a thin slot, in the leading edge of the airfoil at two heights. The first height, referred to as Method 1, was immediately along the endwall, the second height, Method 2, was locatedat ~1/3 of the approaching boundary layer height. Five suction rates were tested, 0%, 6.5%, 11%, 15% and 20% of the boundary layer mass flow was removed at a constant rate. Both methods reduced the effects of the HV with increasing suction on the symmetry, 0.5-D and 1-D planes. Method 2 performed better at reducing the surface heattransfer but Method 1 outperformed Method 2 aerodynamically by completely removing the HV structure when the 11% suction rate was applied. This method however produced other adverse effects such as high surface shear stress and localized areas of high heat transfer near the slot edges at high suction rates.","abstract_html":"Two methods of flow control were designed to mitigate the effects of the horseshoe vortex structure (HV) at an airfoil/endwall junction. An experimental study was conducted in a low-speed wind tunnel to quantify the effects of localized boundary layer removal on surface heat transfer. A transient infrared technique was used to measure theconvective heat transfer values along the surrounding surface. Particle image velocimetry was used to collect the time-mean velocity vectors of the flow field adjacent to the endwall along three planes of interest. Boundary layer suction was applied through a thin slot, in the leading edge of the airfoil at two heights. The first height, referred to as Method 1, was immediately along the endwall, the second height, Method 2, was locatedat ~1/3 of the approaching boundary layer height. Five suction rates were tested, 0%, 6.5%, 11%, 15% and 20% of the boundary layer mass flow was removed at a constant rate. Both methods reduced the effects of the HV with increasing suction on the symmetry, 0.5-D and 1-D planes. Method 2 performed better at reducing the surface heattransfer but Method 1 outperformed Method 2 aerodynamically by completely removing the HV structure when the 11% suction rate was applied. This method however produced other adverse effects such as high surface shear stress and localized areas of high heat transfer near the slot edges at high suction rates.","abstract_has_math":false,"creators":["Hollis, Rebecca M."],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Aeronautical and Astronautical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Bons, Jeffrey P."],"committee_members":[],"year":2009,"date_issued":"2009-09-08","date_published":"2009-09-08","updated_at":"2026-11-27T04:34:13Z","subjects":["Fluid Dynamics","horseshoe vortex","flow control","boundary layer removal","heat transfer"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1243977349","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1243977349","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1243977349","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1243977349","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Bons, Jeffrey P."]},{"key":"dc:creator","label":"Author","values":["Hollis, Rebecca M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-09-08"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical and Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluid Dynamics","horseshoe vortex","flow control","boundary layer removal","heat transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1243977349"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Two methods of flow control were designed to mitigate the effects of the horseshoe vortex structure (HV) at an airfoil/endwall junction. An experimental study was conducted in a low-speed wind tunnel to quantify the effects of localized boundary layer removal on surface heat transfer. A transient infrared technique was used to measure theconvective heat transfer values along the surrounding surface. Particle image velocimetry was used to collect the time-mean velocity vectors of the flow field adjacent to the endwall along three planes of interest. Boundary layer suction was applied through a thin slot, in the leading edge of the airfoil at two heights. The first height, referred to as Method 1, was immediately along the endwall, the second height, Method 2, was locatedat ~1/3 of the approaching boundary layer height. Five suction rates were tested, 0%, 6.5%, 11%, 15% and 20% of the boundary layer mass flow was removed at a constant rate. Both methods reduced the effects of the HV with increasing suction on the symmetry, 0.5-D and 1-D planes. Method 2 performed better at reducing the surface heattransfer but Method 1 outperformed Method 2 aerodynamically by completely removing the HV structure when the 11% suction rate was applied. This method however produced other adverse effects such as high surface shear stress and localized areas of high heat transfer near the slot edges at high suction rates."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.139","2.88 MB"]},{"key":"dc:title","label":"Title","values":["The Effects of Localized Blade Endwall Suction on Surface Heat Transfer"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Bons, Jeffrey P."],"dc:creator":["Hollis, Rebecca M."],"dc:date":["2009-09-08"],"dc:description":["Two methods of flow control were designed to mitigate the effects of the horseshoe vortex structure (HV) at an airfoil/endwall junction. An experimental study was conducted in a low-speed wind tunnel to quantify the effects of localized boundary layer removal on surface heat transfer. A transient infrared technique was used to measure theconvective heat transfer values along the surrounding surface. Particle image velocimetry was used to collect the time-mean velocity vectors of the flow field adjacent to the endwall along three planes of interest. Boundary layer suction was applied through a thin slot, in the leading edge of the airfoil at two heights. The first height, referred to as Method 1, was immediately along the endwall, the second height, Method 2, was locatedat ~1/3 of the approaching boundary layer height. Five suction rates were tested, 0%, 6.5%, 11%, 15% and 20% of the boundary layer mass flow was removed at a constant rate. Both methods reduced the effects of the HV with increasing suction on the symmetry, 0.5-D and 1-D planes. Method 2 performed better at reducing the surface heattransfer but Method 1 outperformed Method 2 aerodynamically by completely removing the HV structure when the 11% suction rate was applied. This method however produced other adverse effects such as high surface shear stress and localized areas of high heat transfer near the slot edges at high suction rates."],"dc:format":["application/pdf","p.139","2.88 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1243977349"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Fluid Dynamics","horseshoe vortex","flow control","boundary layer removal","heat transfer"],"dc:title":["The Effects of Localized Blade Endwall Suction on Surface Heat Transfer"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Aeronautical and Astronautical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:34:13Z"}