{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1244049980"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1244049980","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A COMPARISON OF RESISTANCE TO FRACTURE AND DEFORMATION BETWEEN ONE AND TWO-PIECE SMALL DIAMETER DENTAL IMPLANTS","abstract":"Small diameter dental implants have been developed to overcome clinical settings of limited bone and dental spacing. These small diameter implants are available as a two-piece implant and prosthetic abutment or a one-piece implant. A concern with small diameter implants is an increased predisposition to implant and abutment fracture. The purpose of this research is to explore the strength characteristics of one and two-piece small diameter implants. 10 Astra Tech OsseoSpeed Ø3.0 x 13mm implants with Ø4.0 2mm TiDesign abutments (two-piece) where compared with 10 BioHorizons one-piece Ø3.0 x 15mm implants (one-piece). The implants were secured in a rigid clamp and subjected to static loading. The mean peak load was recorded for the specimens as well as load/displacement data. The mean peak load values for the one and two-piece implants were 414 N and 187 N respectively. The one-piece implants were significantly stronger than the two-piece implants. The practitioner should utilize careful patient selection when using two-piece small diameter implants.","abstract_html":"Small diameter dental implants have been developed to overcome clinical settings of limited bone and dental spacing. These small diameter implants are available as a two-piece implant and prosthetic abutment or a one-piece implant. A concern with small diameter implants is an increased predisposition to implant and abutment fracture. The purpose of this research is to explore the strength characteristics of one and two-piece small diameter implants. 10 Astra Tech OsseoSpeed Ø3.0 x 13mm implants with Ø4.0 2mm TiDesign abutments (two-piece) where compared with 10 BioHorizons one-piece Ø3.0 x 15mm implants (one-piece). The implants were secured in a rigid clamp and subjected to static loading. The mean peak load was recorded for the specimens as well as load/displacement data. The mean peak load values for the one and two-piece implants were 414 N and 187 N respectively. The one-piece implants were significantly stronger than the two-piece implants. The practitioner should utilize careful patient selection when using two-piece small diameter implants.","abstract_has_math":false,"creators":["Jacobs, James Owen"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":[],"advisors":["Larsen, Peter"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-09-08","date_published":"2009-09-08","updated_at":"2026-11-27T04:34:13Z","subjects":["Dental Care","Small-diameter dental implant fatigue strength"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1244049980","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1244049980","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1244049980","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1244049980","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Larsen, Peter"]},{"key":"dc:creator","label":"Author","values":["Jacobs, James Owen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-09-08"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dental Care","Small-diameter dental implant fatigue strength"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1244049980"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Small diameter dental implants have been developed to overcome clinical settings of limited bone and dental spacing. These small diameter implants are available as a two-piece implant and prosthetic abutment or a one-piece implant. A concern with small diameter implants is an increased predisposition to implant and abutment fracture. The purpose of this research is to explore the strength characteristics of one and two-piece small diameter implants. 10 Astra Tech OsseoSpeed Ø3.0 x 13mm implants with Ø4.0 2mm TiDesign abutments (two-piece) where compared with 10 BioHorizons one-piece Ø3.0 x 15mm implants (one-piece). The implants were secured in a rigid clamp and subjected to static loading. The mean peak load was recorded for the specimens as well as load/displacement data. The mean peak load values for the one and two-piece implants were 414 N and 187 N respectively. The one-piece implants were significantly stronger than the two-piece implants. The practitioner should utilize careful patient selection when using two-piece small diameter implants."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.30","428.2 KB"]},{"key":"dc:title","label":"Title","values":["A COMPARISON OF RESISTANCE TO FRACTURE AND DEFORMATION BETWEEN ONE AND TWO-PIECE SMALL DIAMETER DENTAL IMPLANTS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Larsen, Peter"],"dc:creator":["Jacobs, James Owen"],"dc:date":["2009-09-08"],"dc:description":["Small diameter dental implants have been developed to overcome clinical settings of limited bone and dental spacing. These small diameter implants are available as a two-piece implant and prosthetic abutment or a one-piece implant. A concern with small diameter implants is an increased predisposition to implant and abutment fracture. The purpose of this research is to explore the strength characteristics of one and two-piece small diameter implants. 10 Astra Tech OsseoSpeed Ø3.0 x 13mm implants with Ø4.0 2mm TiDesign abutments (two-piece) where compared with 10 BioHorizons one-piece Ø3.0 x 15mm implants (one-piece). The implants were secured in a rigid clamp and subjected to static loading. The mean peak load was recorded for the specimens as well as load/displacement data. The mean peak load values for the one and two-piece implants were 414 N and 187 N respectively. The one-piece implants were significantly stronger than the two-piece implants. The practitioner should utilize careful patient selection when using two-piece small diameter implants."],"dc:format":["application/pdf","p.30","428.2 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1244049980"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Dental Care","Small-diameter dental implant fatigue strength"],"dc:title":["A COMPARISON OF RESISTANCE TO FRACTURE AND DEFORMATION BETWEEN ONE AND TWO-PIECE SMALL DIAMETER DENTAL IMPLANTS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:34:13Z"}