{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1281581537"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1281581537","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Steady and Harmonic Predictions for a Single-Stage Fully Cooled Turbine","abstract":"<p>The research described in this thesis was supported under the NASA/DoD URETI program, and is designed to advance the state-of-the-art in the area of the aerodynamic and heat-transfer performance of a single stage, high-pressure, fully cooled turbine. This particular study is an important computational component of a combined experimental and computational research program conducted at The Ohio State University Gas Turbine Laboratory (OSU GTL). The computational model enhancements included in this particular phase of the overall investigation (Using Numeca’s FINE/Turbo code to generate fully cooled predictions) are a new, highly gridded mesh, the ability of the new code to run isothermal wall solutions, a more correct representation of the experimental geometry, the introduction of film cooling, and finally, generating both steady-state and unsteady harmonic solutions. The code FINE/Turbo has been used by the GTL for several years, and has proven to be a useful predictive tool.</p><p>Several modeling details are considered when performing these computations; attention to detail is shown to be especially important when attempting to acquire heat-transfer predictions. A y+ sensitivity study shows that surface static-pressure predictions are relatively insensitive to y+, but heat-transfer predictions are very sensitive to changes in the y+ range. All computations utilize y+ values in the range of 1 to 10, which is required by the Spalart-Allmaras turbulence model. This study uses the distributed source term injection approach to model film cooling. </p><p>For the configuration - both geometry and instrumentation rake locations - of the turbine stage used for this work, two computational models are described; a short channel that does not model the complete experimental configuration, and a new full channel mesh that does model the complete experimental domain. It is found that incorporating the inlet channel (upstream of the vane) does impact the blade heat-transfer predictions by as much a 45%. This difference between the short and full channel heat-transfer predictions is most noticeable on the blade suction surface, below 20% span and above 70% span.</p><p>Results are obtained for five different cases. These cases represent variations of the following parameters; cooled vs. un-cooled; short vs. full channel; steady vs. harmonic. For each case, static pressure and surface heat-transfer predictions are presented for the vane and the blade. Comparisons between these predictions are also presented. In general, it is found that both the un-cooled and cooled static-pressure predictions demonstrated good agreement with the data. It is now considered possible to make comparisons between fully cooled computations and fully cooled experimental results. For the heat-transfer, these new predictions represent an improvement over previous predictions; however agreement with the experimental results is still not considered to be good. The most noticeable deviation between the heat-transfer predictions and the data occurs on the blade pressure surface, at approximately 50% wetted distance.</p>","abstract_html":"&lt;p&gt;The research described in this thesis was supported under the NASA/DoD URETI program, and is designed to advance the state-of-the-art in the area of the aerodynamic and heat-transfer performance of a single stage, high-pressure, fully cooled turbine. This particular study is an important computational component of a combined experimental and computational research program conducted at The Ohio State University Gas Turbine Laboratory (OSU GTL). The computational model enhancements included in this particular phase of the overall investigation (Using Numeca’s FINE/Turbo code to generate fully cooled predictions) are a new, highly gridded mesh, the ability of the new code to run isothermal wall solutions, a more correct representation of the experimental geometry, the introduction of film cooling, and finally, generating both steady-state and unsteady harmonic solutions. The code FINE/Turbo has been used by the GTL for several years, and has proven to be a useful predictive tool.&lt;/p&gt;&lt;p&gt;Several modeling details are considered when performing these computations; attention to detail is shown to be especially important when attempting to acquire heat-transfer predictions. A y+ sensitivity study shows that surface static-pressure predictions are relatively insensitive to y+, but heat-transfer predictions are very sensitive to changes in the y+ range. All computations utilize y+ values in the range of 1 to 10, which is required by the Spalart-Allmaras turbulence model. This study uses the distributed source term injection approach to model film cooling. &lt;/p&gt;&lt;p&gt;For the configuration - both geometry and instrumentation rake locations - of the turbine stage used for this work, two computational models are described; a short channel that does not model the complete experimental configuration, and a new full channel mesh that does model the complete experimental domain. It is found that incorporating the inlet channel (upstream of the vane) does impact the blade heat-transfer predictions by as much a 45%. This difference between the short and full channel heat-transfer predictions is most noticeable on the blade suction surface, below 20% span and above 70% span.&lt;/p&gt;&lt;p&gt;Results are obtained for five different cases. These cases represent variations of the following parameters; cooled vs. un-cooled; short vs. full channel; steady vs. harmonic. For each case, static pressure and surface heat-transfer predictions are presented for the vane and the blade. Comparisons between these predictions are also presented. In general, it is found that both the un-cooled and cooled static-pressure predictions demonstrated good agreement with the data. It is now considered possible to make comparisons between fully cooled computations and fully cooled experimental results. For the heat-transfer, these new predictions represent an improvement over previous predictions; however agreement with the experimental results is still not considered to be good. The most noticeable deviation between the heat-transfer predictions and the data occurs on the blade pressure surface, at approximately 50% wetted distance.&lt;/p&gt;","abstract_has_math":false,"creators":["Wishart, Mark Brody"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Dunn, Michael"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-10-22","date_published":"2010-10-22","updated_at":"2026-11-27T04:35:01Z","subjects":["Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1281581537","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1281581537","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1281581537","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1281581537","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dunn, Michael"]},{"key":"dc:creator","label":"Author","values":["Wishart, Mark Brody"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-22"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1281581537"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The research described in this thesis was supported under the NASA/DoD URETI program, and is designed to advance the state-of-the-art in the area of the aerodynamic and heat-transfer performance of a single stage, high-pressure, fully cooled turbine. This particular study is an important computational component of a combined experimental and computational research program conducted at The Ohio State University Gas Turbine Laboratory (OSU GTL). The computational model enhancements included in this particular phase of the overall investigation (Using Numeca’s FINE/Turbo code to generate fully cooled predictions) are a new, highly gridded mesh, the ability of the new code to run isothermal wall solutions, a more correct representation of the experimental geometry, the introduction of film cooling, and finally, generating both steady-state and unsteady harmonic solutions. The code FINE/Turbo has been used by the GTL for several years, and has proven to be a useful predictive tool.</p><p>Several modeling details are considered when performing these computations; attention to detail is shown to be especially important when attempting to acquire heat-transfer predictions. A y+ sensitivity study shows that surface static-pressure predictions are relatively insensitive to y+, but heat-transfer predictions are very sensitive to changes in the y+ range. All computations utilize y+ values in the range of 1 to 10, which is required by the Spalart-Allmaras turbulence model. This study uses the distributed source term injection approach to model film cooling. </p><p>For the configuration - both geometry and instrumentation rake locations - of the turbine stage used for this work, two computational models are described; a short channel that does not model the complete experimental configuration, and a new full channel mesh that does model the complete experimental domain. It is found that incorporating the inlet channel (upstream of the vane) does impact the blade heat-transfer predictions by as much a 45%. This difference between the short and full channel heat-transfer predictions is most noticeable on the blade suction surface, below 20% span and above 70% span.</p><p>Results are obtained for five different cases. These cases represent variations of the following parameters; cooled vs. un-cooled; short vs. full channel; steady vs. harmonic. For each case, static pressure and surface heat-transfer predictions are presented for the vane and the blade. Comparisons between these predictions are also presented. In general, it is found that both the un-cooled and cooled static-pressure predictions demonstrated good agreement with the data. It is now considered possible to make comparisons between fully cooled computations and fully cooled experimental results. For the heat-transfer, these new predictions represent an improvement over previous predictions; however agreement with the experimental results is still not considered to be good. The most noticeable deviation between the heat-transfer predictions and the data occurs on the blade pressure surface, at approximately 50% wetted distance.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.119","29.76 MB"]},{"key":"dc:title","label":"Title","values":["Steady and Harmonic Predictions for a Single-Stage Fully Cooled Turbine"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dunn, Michael"],"dc:creator":["Wishart, Mark Brody"],"dc:date":["2010-10-22"],"dc:description":["<p>The research described in this thesis was supported under the NASA/DoD URETI program, and is designed to advance the state-of-the-art in the area of the aerodynamic and heat-transfer performance of a single stage, high-pressure, fully cooled turbine. This particular study is an important computational component of a combined experimental and computational research program conducted at The Ohio State University Gas Turbine Laboratory (OSU GTL). The computational model enhancements included in this particular phase of the overall investigation (Using Numeca’s FINE/Turbo code to generate fully cooled predictions) are a new, highly gridded mesh, the ability of the new code to run isothermal wall solutions, a more correct representation of the experimental geometry, the introduction of film cooling, and finally, generating both steady-state and unsteady harmonic solutions. The code FINE/Turbo has been used by the GTL for several years, and has proven to be a useful predictive tool.</p><p>Several modeling details are considered when performing these computations; attention to detail is shown to be especially important when attempting to acquire heat-transfer predictions. A y+ sensitivity study shows that surface static-pressure predictions are relatively insensitive to y+, but heat-transfer predictions are very sensitive to changes in the y+ range. All computations utilize y+ values in the range of 1 to 10, which is required by the Spalart-Allmaras turbulence model. This study uses the distributed source term injection approach to model film cooling. </p><p>For the configuration - both geometry and instrumentation rake locations - of the turbine stage used for this work, two computational models are described; a short channel that does not model the complete experimental configuration, and a new full channel mesh that does model the complete experimental domain. It is found that incorporating the inlet channel (upstream of the vane) does impact the blade heat-transfer predictions by as much a 45%. This difference between the short and full channel heat-transfer predictions is most noticeable on the blade suction surface, below 20% span and above 70% span.</p><p>Results are obtained for five different cases. These cases represent variations of the following parameters; cooled vs. un-cooled; short vs. full channel; steady vs. harmonic. For each case, static pressure and surface heat-transfer predictions are presented for the vane and the blade. Comparisons between these predictions are also presented. In general, it is found that both the un-cooled and cooled static-pressure predictions demonstrated good agreement with the data. It is now considered possible to make comparisons between fully cooled computations and fully cooled experimental results. For the heat-transfer, these new predictions represent an improvement over previous predictions; however agreement with the experimental results is still not considered to be good. The most noticeable deviation between the heat-transfer predictions and the data occurs on the blade pressure surface, at approximately 50% wetted distance.</p>"],"dc:format":["application/pdf","p.119","29.76 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1281581537"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering"],"dc:title":["Steady and Harmonic Predictions for a Single-Stage Fully Cooled Turbine"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:01Z"}