{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1284767673"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1284767673","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Transient Aerothermodynamics of Flow Initialization for a Flat Plate Film Cooling Experiment in a Medium Duration Blowdown Wind Tunnel Facility","abstract":"The magnitude of the temperature increase as a result of compression heating during the starting process of a high Reynolds number film cooling experiment was more than initially anticipated, creating a mismatch in the design conditions. A review of the time-accurate data showed that two fluid mechanisms, ingestion into the cooling holes during the starting process and compression heating were the causes of the problem, but in different amounts based on the experimental apparatus and time scales involved. The goal of this thesis is to use one of the facilities, the Small Calibration Facility, in conjunction with an analytical model developed for this task to determine how to properly change the start procedure to rectify the problem. The solution to the problem involved adding extra cooling mass at specific times. Several methods attempted, and this particular approach yielded excellent results. In addition, the rework of the start-up procedure allowed for better tuning of the blowdown facility, which resulted in a more constant blowing ratio throughout the experiment.","abstract_html":"The magnitude of the temperature increase as a result of compression heating during the starting process of a high Reynolds number film cooling experiment was more than initially anticipated, creating a mismatch in the design conditions. A review of the time-accurate data showed that two fluid mechanisms, ingestion into the cooling holes during the starting process and compression heating were the causes of the problem, but in different amounts based on the experimental apparatus and time scales involved. The goal of this thesis is to use one of the facilities, the Small Calibration Facility, in conjunction with an analytical model developed for this task to determine how to properly change the start procedure to rectify the problem. The solution to the problem involved adding extra cooling mass at specific times. Several methods attempted, and this particular approach yielded excellent results. In addition, the rework of the start-up procedure allowed for better tuning of the blowdown facility, which resulted in a more constant blowing ratio throughout the experiment.","abstract_has_math":false,"creators":["Boehler, Michael David"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Aero/Astro Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Dunn, Mike","Haldeman, Charles"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11-01","date_published":"2010-11-01","updated_at":"2026-11-27T04:35:05Z","subjects":["Mechanical Engineering","film cooling","blowdown","flat plate","compression heating","ingestion"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1284767673","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1284767673","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1284767673","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1284767673","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dunn, Mike","Haldeman, Charles"]},{"key":"dc:creator","label":"Author","values":["Boehler, Michael David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-11-01"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aero/Astro Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","film cooling","blowdown","flat plate","compression heating","ingestion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1284767673"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The magnitude of the temperature increase as a result of compression heating during the starting process of a high Reynolds number film cooling experiment was more than initially anticipated, creating a mismatch in the design conditions. A review of the time-accurate data showed that two fluid mechanisms, ingestion into the cooling holes during the starting process and compression heating were the causes of the problem, but in different amounts based on the experimental apparatus and time scales involved. The goal of this thesis is to use one of the facilities, the Small Calibration Facility, in conjunction with an analytical model developed for this task to determine how to properly change the start procedure to rectify the problem. The solution to the problem involved adding extra cooling mass at specific times. Several methods attempted, and this particular approach yielded excellent results. In addition, the rework of the start-up procedure allowed for better tuning of the blowdown facility, which resulted in a more constant blowing ratio throughout the experiment."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.61 MB"]},{"key":"dc:title","label":"Title","values":["Transient Aerothermodynamics of Flow Initialization for a Flat Plate Film Cooling Experiment in a Medium Duration Blowdown Wind Tunnel Facility"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dunn, Mike","Haldeman, Charles"],"dc:creator":["Boehler, Michael David"],"dc:date":["2010-11-01"],"dc:description":["The magnitude of the temperature increase as a result of compression heating during the starting process of a high Reynolds number film cooling experiment was more than initially anticipated, creating a mismatch in the design conditions. A review of the time-accurate data showed that two fluid mechanisms, ingestion into the cooling holes during the starting process and compression heating were the causes of the problem, but in different amounts based on the experimental apparatus and time scales involved. The goal of this thesis is to use one of the facilities, the Small Calibration Facility, in conjunction with an analytical model developed for this task to determine how to properly change the start procedure to rectify the problem. The solution to the problem involved adding extra cooling mass at specific times. Several methods attempted, and this particular approach yielded excellent results. In addition, the rework of the start-up procedure allowed for better tuning of the blowdown facility, which resulted in a more constant blowing ratio throughout the experiment."],"dc:format":["application/pdf","2.61 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1284767673"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","film cooling","blowdown","flat plate","compression heating","ingestion"],"dc:title":["Transient Aerothermodynamics of Flow Initialization for a Flat Plate Film Cooling Experiment in a Medium Duration Blowdown Wind Tunnel Facility"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Aero/Astro Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:05Z"}