{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1285044595"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1285044595","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of a Single-shot Lifetime PSP Measurement Technique for Rotating Surfaces","abstract":"<p>In this work, the viability of using pressure-sensitive paints as a pressure sensor on rotating surfaces with unsteady pressure fluctuations has been investigated. A lifetime-based single-shot technique is demonstrated on a small prototype rotor with blade-tip speeds on the order of 50 m/s. In the single-shot approach, all of the required intensity information is acquired from excitation by a single pulse of light to avoid any errors caused by non-uniformities of the illumination and paint application on the surface. This technique eliminates the need of image averaging, and provides instantaneous surface pressure even for low-speed applications. PSP with pressure sensitivity of 0.8% change in ratio of image-intensity per kPa, a 532nm PIV laser system, optics, and a fire-wire CCD camera are used for this application. The lifetime sensitivity to oxygen concentration of some widely used pressure-sensitive paints has been investigated using a photomultiplier tube as well as a CCD camera, with respect to possible abilities and limitations of the paints for the discussed application. The results of the phase-locked lifetime measurements in environments having overall surface pressure gradients as small as 3.0 kPa show that this technique is capable of accurately resolving small pressure changes.</p><p>An unrecognized patterned noise is observed when the emission intensity of the PSP is low for the single-shot mode and an analytical filtering is proposed to remove the impact of “patterned noise” in the reduced ratioed image. This filtering approach is based on applying a low-pass filter on the convolution of histogram obtained for the ratioed image along horizontal axis of image which is determined by the direction of “patterned noise”.</p>","abstract_html":"&lt;p&gt;In this work, the viability of using pressure-sensitive paints as a pressure sensor on rotating surfaces with unsteady pressure fluctuations has been investigated. A lifetime-based single-shot technique is demonstrated on a small prototype rotor with blade-tip speeds on the order of 50 m/s. In the single-shot approach, all of the required intensity information is acquired from excitation by a single pulse of light to avoid any errors caused by non-uniformities of the illumination and paint application on the surface. This technique eliminates the need of image averaging, and provides instantaneous surface pressure even for low-speed applications. PSP with pressure sensitivity of 0.8% change in ratio of image-intensity per kPa, a 532nm PIV laser system, optics, and a fire-wire CCD camera are used for this application. The lifetime sensitivity to oxygen concentration of some widely used pressure-sensitive paints has been investigated using a photomultiplier tube as well as a CCD camera, with respect to possible abilities and limitations of the paints for the discussed application. The results of the phase-locked lifetime measurements in environments having overall surface pressure gradients as small as 3.0 kPa show that this technique is capable of accurately resolving small pressure changes.&lt;/p&gt;&lt;p&gt;An unrecognized patterned noise is observed when the emission intensity of the PSP is low for the single-shot mode and an analytical filtering is proposed to remove the impact of “patterned noise” in the reduced ratioed image. This filtering approach is based on applying a low-pass filter on the convolution of histogram obtained for the ratioed image along horizontal axis of image which is determined by the direction of “patterned noise”.&lt;/p&gt;","abstract_has_math":false,"creators":["Kumar, Pradeep"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Aero/Astro Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gregory, James"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11-02","date_published":"2010-11-02","updated_at":"2026-11-27T04:35:05Z","subjects":["Mechanical Engineering","PSP","single-shot","lifetime","measurements","rotating surfaces","rotorcraft"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1285044595","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1285044595","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1285044595","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1285044595","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gregory, James"]},{"key":"dc:creator","label":"Author","values":["Kumar, Pradeep"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-11-02"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aero/Astro Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","PSP","single-shot","lifetime","measurements","rotating surfaces","rotorcraft"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1285044595"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>In this work, the viability of using pressure-sensitive paints as a pressure sensor on rotating surfaces with unsteady pressure fluctuations has been investigated. A lifetime-based single-shot technique is demonstrated on a small prototype rotor with blade-tip speeds on the order of 50 m/s. In the single-shot approach, all of the required intensity information is acquired from excitation by a single pulse of light to avoid any errors caused by non-uniformities of the illumination and paint application on the surface. This technique eliminates the need of image averaging, and provides instantaneous surface pressure even for low-speed applications. PSP with pressure sensitivity of 0.8% change in ratio of image-intensity per kPa, a 532nm PIV laser system, optics, and a fire-wire CCD camera are used for this application. The lifetime sensitivity to oxygen concentration of some widely used pressure-sensitive paints has been investigated using a photomultiplier tube as well as a CCD camera, with respect to possible abilities and limitations of the paints for the discussed application. The results of the phase-locked lifetime measurements in environments having overall surface pressure gradients as small as 3.0 kPa show that this technique is capable of accurately resolving small pressure changes.</p><p>An unrecognized patterned noise is observed when the emission intensity of the PSP is low for the single-shot mode and an analytical filtering is proposed to remove the impact of “patterned noise” in the reduced ratioed image. This filtering approach is based on applying a low-pass filter on the convolution of histogram obtained for the ratioed image along horizontal axis of image which is determined by the direction of “patterned noise”.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.126","2.39 MB"]},{"key":"dc:title","label":"Title","values":["Development of a Single-shot Lifetime PSP Measurement Technique for Rotating Surfaces"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gregory, James"],"dc:creator":["Kumar, Pradeep"],"dc:date":["2010-11-02"],"dc:description":["<p>In this work, the viability of using pressure-sensitive paints as a pressure sensor on rotating surfaces with unsteady pressure fluctuations has been investigated. A lifetime-based single-shot technique is demonstrated on a small prototype rotor with blade-tip speeds on the order of 50 m/s. In the single-shot approach, all of the required intensity information is acquired from excitation by a single pulse of light to avoid any errors caused by non-uniformities of the illumination and paint application on the surface. This technique eliminates the need of image averaging, and provides instantaneous surface pressure even for low-speed applications. PSP with pressure sensitivity of 0.8% change in ratio of image-intensity per kPa, a 532nm PIV laser system, optics, and a fire-wire CCD camera are used for this application. The lifetime sensitivity to oxygen concentration of some widely used pressure-sensitive paints has been investigated using a photomultiplier tube as well as a CCD camera, with respect to possible abilities and limitations of the paints for the discussed application. The results of the phase-locked lifetime measurements in environments having overall surface pressure gradients as small as 3.0 kPa show that this technique is capable of accurately resolving small pressure changes.</p><p>An unrecognized patterned noise is observed when the emission intensity of the PSP is low for the single-shot mode and an analytical filtering is proposed to remove the impact of “patterned noise” in the reduced ratioed image. This filtering approach is based on applying a low-pass filter on the convolution of histogram obtained for the ratioed image along horizontal axis of image which is determined by the direction of “patterned noise”.</p>"],"dc:format":["application/pdf","p.126","2.39 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1285044595"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","PSP","single-shot","lifetime","measurements","rotating surfaces","rotorcraft"],"dc:title":["Development of a Single-shot Lifetime PSP Measurement Technique for Rotating Surfaces"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Aero/Astro Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:05Z"}