{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1293632071"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1293632071","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Super Resolution in Ultra High Field MRI - A Comparison","abstract":"High resolution isotropic 3D scanning for MR imaging is practically limited by thelength of the scan for in vivo applications. The common practice for acquiring 3Dvolumes in MRI is to acquire 2D slices and stack the slices to get a 3D volume. How-ever, the through-plane resolution in these 3D volumes is typically much poorer thanthat achieved in-plane by a factor of 5-10. Super resolution is a technique that hasbeen proposed to improve the through-plane resolution in 2D multi-slice images. Themain objective of this study is to compare super resolution 3D volumes reconstructedusing dierent low-resolution acquisition geometries versus isotropically acquired 3DMRI (gold standard), and to demonstrate the technique in in vivo settings. Bothqualitative and quantitative comparisons are carried out to evaluate the performanceof the algorithms.","abstract_html":"High resolution isotropic 3D scanning for MR imaging is practically limited by thelength of the scan for in vivo applications. The common practice for acquiring 3Dvolumes in MRI is to acquire 2D slices and stack the slices to get a 3D volume. How-ever, the through-plane resolution in these 3D volumes is typically much poorer thanthat achieved in-plane by a factor of 5-10. Super resolution is a technique that hasbeen proposed to improve the through-plane resolution in 2D multi-slice images. Themain objective of this study is to compare super resolution 3D volumes reconstructedusing dierent low-resolution acquisition geometries versus isotropically acquired 3DMRI (gold standard), and to demonstrate the technique in in vivo settings. Bothqualitative and quantitative comparisons are carried out to evaluate the performanceof the algorithms.","abstract_has_math":false,"creators":["Manivannan, Niranchana"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Clymer, Dr.Bradley"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T04:35:10Z","subjects":["Biomedical Research","Electrical Engineering","Medical Imaging","Super resolution","9.4T","orthogonal","isotropic 3D","through-plane","MRI"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1293632071","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1293632071","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1293632071","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1293632071","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Clymer, Dr.Bradley"]},{"key":"dc:creator","label":"Author","values":["Manivannan, Niranchana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Electrical Engineering","Medical Imaging","Super resolution","9.4T","orthogonal","isotropic 3D","through-plane","MRI"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1293632071"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["High resolution isotropic 3D scanning for MR imaging is practically limited by thelength of the scan for in vivo applications. The common practice for acquiring 3Dvolumes in MRI is to acquire 2D slices and stack the slices to get a 3D volume. How-ever, the through-plane resolution in these 3D volumes is typically much poorer thanthat achieved in-plane by a factor of 5-10. Super resolution is a technique that hasbeen proposed to improve the through-plane resolution in 2D multi-slice images. Themain objective of this study is to compare super resolution 3D volumes reconstructedusing dierent low-resolution acquisition geometries versus isotropically acquired 3DMRI (gold standard), and to demonstrate the technique in in vivo settings. Bothqualitative and quantitative comparisons are carried out to evaluate the performanceof the algorithms."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.93 MB"]},{"key":"dc:title","label":"Title","values":["Super Resolution in Ultra High Field MRI - A Comparison"]}]}],"canonical_facts":{"dc:contributor.advisor":["Clymer, Dr.Bradley"],"dc:creator":["Manivannan, Niranchana"],"dc:date":["2010"],"dc:description":["High resolution isotropic 3D scanning for MR imaging is practically limited by thelength of the scan for in vivo applications. The common practice for acquiring 3Dvolumes in MRI is to acquire 2D slices and stack the slices to get a 3D volume. How-ever, the through-plane resolution in these 3D volumes is typically much poorer thanthat achieved in-plane by a factor of 5-10. Super resolution is a technique that hasbeen proposed to improve the through-plane resolution in 2D multi-slice images. Themain objective of this study is to compare super resolution 3D volumes reconstructedusing dierent low-resolution acquisition geometries versus isotropically acquired 3DMRI (gold standard), and to demonstrate the technique in in vivo settings. Bothqualitative and quantitative comparisons are carried out to evaluate the performanceof the algorithms."],"dc:format":["application/pdf","1.93 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1293632071"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Electrical Engineering","Medical Imaging","Super resolution","9.4T","orthogonal","isotropic 3D","through-plane","MRI"],"dc:title":["Super Resolution in Ultra High Field MRI - A Comparison"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:10Z"}