{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1293736583"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1293736583","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Application of Fast-Responding Pressure-Sensitive Paint to a Hemispherical Dome in Unsteady Transonic Flow","abstract":"<p>The current work focuses on the application of fast-responding polymer/ceramic pressure-sensitive paint (PSP) as an advanced surface pressure measurement technique for the study of unsteady flow fields in large-scale wind tunnels. Three different PSP experimental methods are demonstrated to resolve the surface pressure distribution over a hemispherical dome placed in subsonic flow with freestream Mach number of 0.6 and a total pressure of 71.8 kPa, where the Reynolds Number based on dome diameter (0.254 m) is 2.4 x 10<sup>6</sup>. At this flow condition, a predominant shear layer oscillating at 400 Hz over the test model is observed. Three different PSP methods were employed to study this phenomenon: phase-averaged, real-time, and single-shot. In the phase-averaging technique, LED arrays are phase-locked to the shear layer frequency so that the strobed illumination freezes the motion of the oscillating fluid in one instant and the camera shutter stays open long enough to average the fluid motion over many cycles. In the real-time approach, a high-speed camera was used to capture the shear layer frequency at a shutter speed of 10 kHz without any averaging of the images. In the lifetime-based single-shot approach, the PSP information was acquired from one single laser pulse, which was also able to provide instantaneous surface pressures with high spatial resolution. An assessment of the three test methods is presented, with the advantage and disadvantage of each technique evaluated through example.</p>To study the unsteady fluid dynamic problem in this work using PSP, it is important to demonstrate that the PSP formulation has the capability to accurately resolve the unsteady pressure changes. The response time of the polymer/ceramic PSP was characterized with a dynamic calibration technique using a loudspeaker. The quantitative point-measurement results show that the amplitude response of the PSP behaved like a 4th order dynamic system, with a frequency response of 3700 Hz. The dynamic calibration setup and results are presented.","abstract_html":"&lt;p&gt;The current work focuses on the application of fast-responding polymer/ceramic pressure-sensitive paint (PSP) as an advanced surface pressure measurement technique for the study of unsteady flow fields in large-scale wind tunnels. Three different PSP experimental methods are demonstrated to resolve the surface pressure distribution over a hemispherical dome placed in subsonic flow with freestream Mach number of 0.6 and a total pressure of 71.8 kPa, where the Reynolds Number based on dome diameter (0.254 m) is 2.4 x 10&lt;sup&gt;6&lt;/sup&gt;. At this flow condition, a predominant shear layer oscillating at 400 Hz over the test model is observed. Three different PSP methods were employed to study this phenomenon: phase-averaged, real-time, and single-shot. In the phase-averaging technique, LED arrays are phase-locked to the shear layer frequency so that the strobed illumination freezes the motion of the oscillating fluid in one instant and the camera shutter stays open long enough to average the fluid motion over many cycles. In the real-time approach, a high-speed camera was used to capture the shear layer frequency at a shutter speed of 10 kHz without any averaging of the images. In the lifetime-based single-shot approach, the PSP information was acquired from one single laser pulse, which was also able to provide instantaneous surface pressures with high spatial resolution. An assessment of the three test methods is presented, with the advantage and disadvantage of each technique evaluated through example.&lt;/p&gt;To study the unsteady fluid dynamic problem in this work using PSP, it is important to demonstrate that the PSP formulation has the capability to accurately resolve the unsteady pressure changes. The response time of the polymer/ceramic PSP was characterized with a dynamic calibration technique using a loudspeaker. The quantitative point-measurement results show that the amplitude response of the PSP behaved like a 4th order dynamic system, with a frequency response of 3700 Hz. The dynamic calibration setup and results are presented.","abstract_has_math":false,"creators":["Fang, Shuo"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Aero/Astro Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gregory, James"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T04:35:10Z","subjects":["Aerospace Engineering","pressure-sensitive paint","paint","aerodynamics","hemisphere","hemispherical dome","phase-averaging","real-time","lifetime"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1293736583","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1293736583","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1293736583","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1293736583","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gregory, James"]},{"key":"dc:creator","label":"Author","values":["Fang, Shuo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aero/Astro Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerospace Engineering","pressure-sensitive paint","paint","aerodynamics","hemisphere","hemispherical dome","phase-averaging","real-time","lifetime"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1293736583"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The current work focuses on the application of fast-responding polymer/ceramic pressure-sensitive paint (PSP) as an advanced surface pressure measurement technique for the study of unsteady flow fields in large-scale wind tunnels. Three different PSP experimental methods are demonstrated to resolve the surface pressure distribution over a hemispherical dome placed in subsonic flow with freestream Mach number of 0.6 and a total pressure of 71.8 kPa, where the Reynolds Number based on dome diameter (0.254 m) is 2.4 x 10<sup>6</sup>. At this flow condition, a predominant shear layer oscillating at 400 Hz over the test model is observed. Three different PSP methods were employed to study this phenomenon: phase-averaged, real-time, and single-shot. In the phase-averaging technique, LED arrays are phase-locked to the shear layer frequency so that the strobed illumination freezes the motion of the oscillating fluid in one instant and the camera shutter stays open long enough to average the fluid motion over many cycles. In the real-time approach, a high-speed camera was used to capture the shear layer frequency at a shutter speed of 10 kHz without any averaging of the images. In the lifetime-based single-shot approach, the PSP information was acquired from one single laser pulse, which was also able to provide instantaneous surface pressures with high spatial resolution. An assessment of the three test methods is presented, with the advantage and disadvantage of each technique evaluated through example.</p>To study the unsteady fluid dynamic problem in this work using PSP, it is important to demonstrate that the PSP formulation has the capability to accurately resolve the unsteady pressure changes. The response time of the polymer/ceramic PSP was characterized with a dynamic calibration technique using a loudspeaker. The quantitative point-measurement results show that the amplitude response of the PSP behaved like a 4th order dynamic system, with a frequency response of 3700 Hz. The dynamic calibration setup and results are presented."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.111","1.49 MB"]},{"key":"dc:title","label":"Title","values":["Application of Fast-Responding Pressure-Sensitive Paint to a Hemispherical Dome in Unsteady Transonic Flow"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gregory, James"],"dc:creator":["Fang, Shuo"],"dc:date":["2010"],"dc:description":["<p>The current work focuses on the application of fast-responding polymer/ceramic pressure-sensitive paint (PSP) as an advanced surface pressure measurement technique for the study of unsteady flow fields in large-scale wind tunnels. Three different PSP experimental methods are demonstrated to resolve the surface pressure distribution over a hemispherical dome placed in subsonic flow with freestream Mach number of 0.6 and a total pressure of 71.8 kPa, where the Reynolds Number based on dome diameter (0.254 m) is 2.4 x 10<sup>6</sup>. At this flow condition, a predominant shear layer oscillating at 400 Hz over the test model is observed. Three different PSP methods were employed to study this phenomenon: phase-averaged, real-time, and single-shot. In the phase-averaging technique, LED arrays are phase-locked to the shear layer frequency so that the strobed illumination freezes the motion of the oscillating fluid in one instant and the camera shutter stays open long enough to average the fluid motion over many cycles. In the real-time approach, a high-speed camera was used to capture the shear layer frequency at a shutter speed of 10 kHz without any averaging of the images. In the lifetime-based single-shot approach, the PSP information was acquired from one single laser pulse, which was also able to provide instantaneous surface pressures with high spatial resolution. An assessment of the three test methods is presented, with the advantage and disadvantage of each technique evaluated through example.</p>To study the unsteady fluid dynamic problem in this work using PSP, it is important to demonstrate that the PSP formulation has the capability to accurately resolve the unsteady pressure changes. The response time of the polymer/ceramic PSP was characterized with a dynamic calibration technique using a loudspeaker. The quantitative point-measurement results show that the amplitude response of the PSP behaved like a 4th order dynamic system, with a frequency response of 3700 Hz. The dynamic calibration setup and results are presented."],"dc:format":["application/pdf","p.111","1.49 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1293736583"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Aerospace Engineering","pressure-sensitive paint","paint","aerodynamics","hemisphere","hemispherical dome","phase-averaging","real-time","lifetime"],"dc:title":["Application of Fast-Responding Pressure-Sensitive Paint to a Hemispherical Dome in Unsteady Transonic Flow"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Aero/Astro Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:10Z"}