{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1306360901"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1306360901","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Quantifying Uncertainty in Reactor Flux/Power Distributions","abstract":"The design and development of a conceptual system for power measurements in a reactor core using in-core sensors has been an ongoing focus of research performed at The Ohio State University. Previous work focused on the development of software that constructs three-dimensional core power distribution using signals from an array of Constant Temperature Power Sensors distributed in the reactor core. The monitoring system processes the sensor signals from the reactor core in such a manner that probabilistic information, in the form of probability distribution functions (pdfs), of reactor power density is obtained at the sensor locations. The desired pdfs of power density at sensor locations were obtained through the implementation of the estimation algorithm Dynamic System Doctor (DSD). Additional work in this area proposed methods to interpolate the pdfs at the measurement points for uniform core compositions. The interpolation methods presented in this thesis extend estimation of the uncertainty in power/flux distribution to heterogeneous cores by combining the knowledge from in-core sensors and reactor core neutron transport calculations. Two significant benefits of such an estimation process are the following:1. It allows quantification of the uncertainty on peaking factors as well as global power/flux distributions and hence evaluation of potential for power upgrades2. It provides data for a best-estimate quantification of design margins.The interpolation method is an adaptation of an interpolation procedure presented by L. Read and utilizes the flux/power distributions obtained from a realistic reactor core model as interpolating functions. The pdfs at the interpolated power/flux values are calculated using a weighted linear interpolation of the sensor pdfs. Four weighting schemes are considered for the power/flux interpolation algorithm. The proposed interpolation methods and each weighting scheme are tested using flux data from models of the Ohio State University Research Reactor (OSURR). The objective of the testing of each scheme is to determine its accuracy/conservatism, and to gauge whether the interpolation is physically representative of the process under consideration. Different methods are compared as to their ability to accurately estimate the pdfs at different positions in the reactor core. In view of the uncertainty in the current material composition of OSURR due to burnup of fuel during the past two decades, the Monte Carlo code MCNP5 is used to generate the “experimental data”. This approach also allows control of the uncertainty on the tally results by changing the number of neutron simulations performed. For the test problems, the OSURR core model flux distributions used as distribution interpolating functions (DIF) were generated by PENTRAN (Parallel Environment Neutral particle Transport) 3-D discrete ordinates code (version 9.36k). Three example problems were used to test the linear interpolation schemes. In these three examples the interpolating method is applied to the flux distribution in and around the Central Irradiation Facility (CIF) of the OSURR. A forward flux based interpolation scheme was found to be accurate in estimating the uncertainty in all three example cases. The results indicate that the detector configuration and the fidelity of the reactor core model which supplied the DIF are the key features in determining the accuracy of all four of the interpolation schemes examined.","abstract_html":"The design and development of a conceptual system for power measurements in a reactor core using in-core sensors has been an ongoing focus of research performed at The Ohio State University. Previous work focused on the development of software that constructs three-dimensional core power distribution using signals from an array of Constant Temperature Power Sensors distributed in the reactor core. The monitoring system processes the sensor signals from the reactor core in such a manner that probabilistic information, in the form of probability distribution functions (pdfs), of reactor power density is obtained at the sensor locations. The desired pdfs of power density at sensor locations were obtained through the implementation of the estimation algorithm Dynamic System Doctor (DSD). Additional work in this area proposed methods to interpolate the pdfs at the measurement points for uniform core compositions. The interpolation methods presented in this thesis extend estimation of the uncertainty in power/flux distribution to heterogeneous cores by combining the knowledge from in-core sensors and reactor core neutron transport calculations. Two significant benefits of such an estimation process are the following:1. It allows quantification of the uncertainty on peaking factors as well as global power/flux distributions and hence evaluation of potential for power upgrades2. It provides data for a best-estimate quantification of design margins.The interpolation method is an adaptation of an interpolation procedure presented by L. Read and utilizes the flux/power distributions obtained from a realistic reactor core model as interpolating functions. The pdfs at the interpolated power/flux values are calculated using a weighted linear interpolation of the sensor pdfs. Four weighting schemes are considered for the power/flux interpolation algorithm. The proposed interpolation methods and each weighting scheme are tested using flux data from models of the Ohio State University Research Reactor (OSURR). The objective of the testing of each scheme is to determine its accuracy/conservatism, and to gauge whether the interpolation is physically representative of the process under consideration. Different methods are compared as to their ability to accurately estimate the pdfs at different positions in the reactor core. In view of the uncertainty in the current material composition of OSURR due to burnup of fuel during the past two decades, the Monte Carlo code MCNP5 is used to generate the “experimental data”. This approach also allows control of the uncertainty on the tally results by changing the number of neutron simulations performed. For the test problems, the OSURR core model flux distributions used as distribution interpolating functions (DIF) were generated by PENTRAN (Parallel Environment Neutral particle Transport) 3-D discrete ordinates code (version 9.36k). Three example problems were used to test the linear interpolation schemes. In these three examples the interpolating method is applied to the flux distribution in and around the Central Irradiation Facility (CIF) of the OSURR. A forward flux based interpolation scheme was found to be accurate in estimating the uncertainty in all three example cases. The results indicate that the detector configuration and the fidelity of the reactor core model which supplied the DIF are the key features in determining the accuracy of all four of the interpolation schemes examined.","abstract_has_math":false,"creators":["Kennedy, Ryanne Ariel"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Nuclear Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Aldemir, Tunc"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-07-22","date_published":"2011-07-22","updated_at":"2026-11-27T04:35:19Z","subjects":["Nuclear Engineering","nuclear reactor","flux","uncertainty quantification","reactor physics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1306360901","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1306360901","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1306360901","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1306360901","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Aldemir, Tunc"]},{"key":"dc:creator","label":"Author","values":["Kennedy, Ryanne Ariel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-07-22"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Engineering","nuclear reactor","flux","uncertainty quantification","reactor physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1306360901"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The design and development of a conceptual system for power measurements in a reactor core using in-core sensors has been an ongoing focus of research performed at The Ohio State University. Previous work focused on the development of software that constructs three-dimensional core power distribution using signals from an array of Constant Temperature Power Sensors distributed in the reactor core. The monitoring system processes the sensor signals from the reactor core in such a manner that probabilistic information, in the form of probability distribution functions (pdfs), of reactor power density is obtained at the sensor locations. The desired pdfs of power density at sensor locations were obtained through the implementation of the estimation algorithm Dynamic System Doctor (DSD). Additional work in this area proposed methods to interpolate the pdfs at the measurement points for uniform core compositions. The interpolation methods presented in this thesis extend estimation of the uncertainty in power/flux distribution to heterogeneous cores by combining the knowledge from in-core sensors and reactor core neutron transport calculations. Two significant benefits of such an estimation process are the following:1. It allows quantification of the uncertainty on peaking factors as well as global power/flux distributions and hence evaluation of potential for power upgrades2. It provides data for a best-estimate quantification of design margins.The interpolation method is an adaptation of an interpolation procedure presented by L. Read and utilizes the flux/power distributions obtained from a realistic reactor core model as interpolating functions. The pdfs at the interpolated power/flux values are calculated using a weighted linear interpolation of the sensor pdfs. Four weighting schemes are considered for the power/flux interpolation algorithm. The proposed interpolation methods and each weighting scheme are tested using flux data from models of the Ohio State University Research Reactor (OSURR). The objective of the testing of each scheme is to determine its accuracy/conservatism, and to gauge whether the interpolation is physically representative of the process under consideration. Different methods are compared as to their ability to accurately estimate the pdfs at different positions in the reactor core. In view of the uncertainty in the current material composition of OSURR due to burnup of fuel during the past two decades, the Monte Carlo code MCNP5 is used to generate the “experimental data”. This approach also allows control of the uncertainty on the tally results by changing the number of neutron simulations performed. For the test problems, the OSURR core model flux distributions used as distribution interpolating functions (DIF) were generated by PENTRAN (Parallel Environment Neutral particle Transport) 3-D discrete ordinates code (version 9.36k). Three example problems were used to test the linear interpolation schemes. In these three examples the interpolating method is applied to the flux distribution in and around the Central Irradiation Facility (CIF) of the OSURR. A forward flux based interpolation scheme was found to be accurate in estimating the uncertainty in all three example cases. The results indicate that the detector configuration and the fidelity of the reactor core model which supplied the DIF are the key features in determining the accuracy of all four of the interpolation schemes examined."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.303","8.81 MB"]},{"key":"dc:title","label":"Title","values":["Quantifying Uncertainty in Reactor Flux/Power Distributions"]}]}],"canonical_facts":{"dc:contributor.advisor":["Aldemir, Tunc"],"dc:creator":["Kennedy, Ryanne Ariel"],"dc:date":["2011-07-22"],"dc:description":["The design and development of a conceptual system for power measurements in a reactor core using in-core sensors has been an ongoing focus of research performed at The Ohio State University. Previous work focused on the development of software that constructs three-dimensional core power distribution using signals from an array of Constant Temperature Power Sensors distributed in the reactor core. The monitoring system processes the sensor signals from the reactor core in such a manner that probabilistic information, in the form of probability distribution functions (pdfs), of reactor power density is obtained at the sensor locations. The desired pdfs of power density at sensor locations were obtained through the implementation of the estimation algorithm Dynamic System Doctor (DSD). Additional work in this area proposed methods to interpolate the pdfs at the measurement points for uniform core compositions. The interpolation methods presented in this thesis extend estimation of the uncertainty in power/flux distribution to heterogeneous cores by combining the knowledge from in-core sensors and reactor core neutron transport calculations. Two significant benefits of such an estimation process are the following:1. It allows quantification of the uncertainty on peaking factors as well as global power/flux distributions and hence evaluation of potential for power upgrades2. It provides data for a best-estimate quantification of design margins.The interpolation method is an adaptation of an interpolation procedure presented by L. Read and utilizes the flux/power distributions obtained from a realistic reactor core model as interpolating functions. The pdfs at the interpolated power/flux values are calculated using a weighted linear interpolation of the sensor pdfs. Four weighting schemes are considered for the power/flux interpolation algorithm. The proposed interpolation methods and each weighting scheme are tested using flux data from models of the Ohio State University Research Reactor (OSURR). The objective of the testing of each scheme is to determine its accuracy/conservatism, and to gauge whether the interpolation is physically representative of the process under consideration. Different methods are compared as to their ability to accurately estimate the pdfs at different positions in the reactor core. In view of the uncertainty in the current material composition of OSURR due to burnup of fuel during the past two decades, the Monte Carlo code MCNP5 is used to generate the “experimental data”. This approach also allows control of the uncertainty on the tally results by changing the number of neutron simulations performed. For the test problems, the OSURR core model flux distributions used as distribution interpolating functions (DIF) were generated by PENTRAN (Parallel Environment Neutral particle Transport) 3-D discrete ordinates code (version 9.36k). Three example problems were used to test the linear interpolation schemes. In these three examples the interpolating method is applied to the flux distribution in and around the Central Irradiation Facility (CIF) of the OSURR. A forward flux based interpolation scheme was found to be accurate in estimating the uncertainty in all three example cases. The results indicate that the detector configuration and the fidelity of the reactor core model which supplied the DIF are the key features in determining the accuracy of all four of the interpolation schemes examined."],"dc:format":["application/pdf","p.303","8.81 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1306360901"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Nuclear Engineering","nuclear reactor","flux","uncertainty quantification","reactor physics"],"dc:title":["Quantifying Uncertainty in Reactor Flux/Power Distributions"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Nuclear Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:19Z"}