{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1312379529"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1312379529","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Prediction of Transient Cooling Behavior in Short-Duration Facilities","abstract":"<p>For many years designers have been pushing turbine inlet temperatures to higher and higher levels in order to create more efficient gas turbine engines. To keep hot section components from melting, advancements in turbine materials and cooling schemes are being explored. One area of research has been focused on the internal passages for cooled turbine vanes and blades. The Ohio State University Gas Turbine Laboratory (OSU GTL) is currently conducting an experimental program to investigate the heat transfer characteristics for internal coolant passages using a multiple passage serpentine channel configuration.</p><p>The internal heat transfer experimental configuration requires cooling gas at a specific temperature. Traditionally at OSU GTL, coolant gas is supplied from a supply tank operating in a blowdown mode. It has proven difficult to maintain the cooling gas at the desired temperature due to the heating effect of the supply tubing and internal passages. </p><p>This thesis develops a model that utilizes a simplified form of the non-dimensional heat exchanger equations to predict fluid temperatures for cooling supply components operating over a wide range of conditions and geometries. Heat exchangers are typically designed with long non-dimensional lengths and short non-dimensional times. However, short non-dimensional lengths and long non-dimensional times are characteristics of cooling system components. Even though the two types of components have drastically different physical geometries and non-dimensional quantities, the simplified non-dimensional equations can be used to model both components. By providing an analytical understanding of the problem as well as a numerical design code, various components undergoing transient heat transfer can be modeled and unique designs can be evaluated. The application of the numerical code reaches beyond the internal heat transfer program and can be applied to a variety of different heat transfer projects at the OSU GTL.</p>","abstract_html":"&lt;p&gt;For many years designers have been pushing turbine inlet temperatures to higher and higher levels in order to create more efficient gas turbine engines. To keep hot section components from melting, advancements in turbine materials and cooling schemes are being explored. One area of research has been focused on the internal passages for cooled turbine vanes and blades. The Ohio State University Gas Turbine Laboratory (OSU GTL) is currently conducting an experimental program to investigate the heat transfer characteristics for internal coolant passages using a multiple passage serpentine channel configuration.&lt;/p&gt;&lt;p&gt;The internal heat transfer experimental configuration requires cooling gas at a specific temperature. Traditionally at OSU GTL, coolant gas is supplied from a supply tank operating in a blowdown mode. It has proven difficult to maintain the cooling gas at the desired temperature due to the heating effect of the supply tubing and internal passages. &lt;/p&gt;&lt;p&gt;This thesis develops a model that utilizes a simplified form of the non-dimensional heat exchanger equations to predict fluid temperatures for cooling supply components operating over a wide range of conditions and geometries. Heat exchangers are typically designed with long non-dimensional lengths and short non-dimensional times. However, short non-dimensional lengths and long non-dimensional times are characteristics of cooling system components. Even though the two types of components have drastically different physical geometries and non-dimensional quantities, the simplified non-dimensional equations can be used to model both components. By providing an analytical understanding of the problem as well as a numerical design code, various components undergoing transient heat transfer can be modeled and unique designs can be evaluated. The application of the numerical code reaches beyond the internal heat transfer program and can be applied to a variety of different heat transfer projects at the OSU GTL.&lt;/p&gt;","abstract_has_math":false,"creators":["Parsons, Mitchell William"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Dunn, Michael"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-09-26","date_published":"2011-09-26","updated_at":"2026-11-26T04:19:54Z","subjects":["Mechanical Engineering","cooling","transient","short-duration"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1312379529","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1312379529","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1312379529","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1312379529","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dunn, Michael"]},{"key":"dc:creator","label":"Author","values":["Parsons, Mitchell William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-09-26"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","cooling","transient","short-duration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1312379529"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>For many years designers have been pushing turbine inlet temperatures to higher and higher levels in order to create more efficient gas turbine engines. To keep hot section components from melting, advancements in turbine materials and cooling schemes are being explored. One area of research has been focused on the internal passages for cooled turbine vanes and blades. The Ohio State University Gas Turbine Laboratory (OSU GTL) is currently conducting an experimental program to investigate the heat transfer characteristics for internal coolant passages using a multiple passage serpentine channel configuration.</p><p>The internal heat transfer experimental configuration requires cooling gas at a specific temperature. Traditionally at OSU GTL, coolant gas is supplied from a supply tank operating in a blowdown mode. It has proven difficult to maintain the cooling gas at the desired temperature due to the heating effect of the supply tubing and internal passages. </p><p>This thesis develops a model that utilizes a simplified form of the non-dimensional heat exchanger equations to predict fluid temperatures for cooling supply components operating over a wide range of conditions and geometries. Heat exchangers are typically designed with long non-dimensional lengths and short non-dimensional times. However, short non-dimensional lengths and long non-dimensional times are characteristics of cooling system components. Even though the two types of components have drastically different physical geometries and non-dimensional quantities, the simplified non-dimensional equations can be used to model both components. By providing an analytical understanding of the problem as well as a numerical design code, various components undergoing transient heat transfer can be modeled and unique designs can be evaluated. The application of the numerical code reaches beyond the internal heat transfer program and can be applied to a variety of different heat transfer projects at the OSU GTL.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.106","2.84 MB"]},{"key":"dc:title","label":"Title","values":["Prediction of Transient Cooling Behavior in Short-Duration Facilities"]}]}],"canonical_facts":{"dc:contributor":["Dunn, Michael"],"dc:creator":["Parsons, Mitchell William"],"dc:date":["2011-09-26"],"dc:description":["<p>For many years designers have been pushing turbine inlet temperatures to higher and higher levels in order to create more efficient gas turbine engines. To keep hot section components from melting, advancements in turbine materials and cooling schemes are being explored. One area of research has been focused on the internal passages for cooled turbine vanes and blades. The Ohio State University Gas Turbine Laboratory (OSU GTL) is currently conducting an experimental program to investigate the heat transfer characteristics for internal coolant passages using a multiple passage serpentine channel configuration.</p><p>The internal heat transfer experimental configuration requires cooling gas at a specific temperature. Traditionally at OSU GTL, coolant gas is supplied from a supply tank operating in a blowdown mode. It has proven difficult to maintain the cooling gas at the desired temperature due to the heating effect of the supply tubing and internal passages. </p><p>This thesis develops a model that utilizes a simplified form of the non-dimensional heat exchanger equations to predict fluid temperatures for cooling supply components operating over a wide range of conditions and geometries. Heat exchangers are typically designed with long non-dimensional lengths and short non-dimensional times. However, short non-dimensional lengths and long non-dimensional times are characteristics of cooling system components. Even though the two types of components have drastically different physical geometries and non-dimensional quantities, the simplified non-dimensional equations can be used to model both components. By providing an analytical understanding of the problem as well as a numerical design code, various components undergoing transient heat transfer can be modeled and unique designs can be evaluated. The application of the numerical code reaches beyond the internal heat transfer program and can be applied to a variety of different heat transfer projects at the OSU GTL.</p>"],"dc:format":["application/pdf","p.106","2.84 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1312379529"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","cooling","transient","short-duration"],"dc:title":["Prediction of Transient Cooling Behavior in Short-Duration Facilities"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-26T04:19:54Z"}