{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1315013452"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1315013452","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Heat-Flux Measurements for a Realistic Cooling Hole Pattern and Different Flow Conditions","abstract":"<p>For many years turbine designers have utilized advancements in film-cooling technology to allow for increased high-pressure turbine inlet temperature. Prediction tools, used to predict the cooling effectiveness of the representative cooling-hole and cooling-hole pattern designs have been successful in keeping the engines on wing for a large number of operational hours, but there is room for and a desire for improvement in the technology. Therefore, a study was undertaken at the OSU GTL to find a way to obtain basic data needed to help improve CFD prediction capability. The particular facility utilized for this work is a medium-duration blowdown facility to which significant improvements in the operational procedure of the cooling system have been made for the purposes of this work and both the facility and the improvements will be described in detail in this thesis. </p><p>In order to keep the CFD validation simple, a flat plate configuration with a realistic cooling hole pattern, representative of a high-pressure turbine blade for which measurements obtained as part of a full-stage experiment were obtained, was utilized along with flow properties of current interest to the industry. The measurements reported in this thesis yielded high response heat-flux measurements along the axial direction of the plate, including locations between the individual rows of cooling holes. The influence of Reynolds numbers on heat transfer to the plate was also explored. Lastly, the temperature of the main flow and the test section walls were varied to determine the effect of cooling on the local adiabatic wall temperature.</p>","abstract_html":"&lt;p&gt;For many years turbine designers have utilized advancements in film-cooling technology to allow for increased high-pressure turbine inlet temperature. Prediction tools, used to predict the cooling effectiveness of the representative cooling-hole and cooling-hole pattern designs have been successful in keeping the engines on wing for a large number of operational hours, but there is room for and a desire for improvement in the technology. Therefore, a study was undertaken at the OSU GTL to find a way to obtain basic data needed to help improve CFD prediction capability. The particular facility utilized for this work is a medium-duration blowdown facility to which significant improvements in the operational procedure of the cooling system have been made for the purposes of this work and both the facility and the improvements will be described in detail in this thesis. &lt;/p&gt;&lt;p&gt;In order to keep the CFD validation simple, a flat plate configuration with a realistic cooling hole pattern, representative of a high-pressure turbine blade for which measurements obtained as part of a full-stage experiment were obtained, was utilized along with flow properties of current interest to the industry. The measurements reported in this thesis yielded high response heat-flux measurements along the axial direction of the plate, including locations between the individual rows of cooling holes. The influence of Reynolds numbers on heat transfer to the plate was also explored. Lastly, the temperature of the main flow and the test section walls were varied to determine the effect of cooling on the local adiabatic wall temperature.&lt;/p&gt;","abstract_has_math":false,"creators":["Davis, Shanon Marie"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Dunn, Michael"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-10-20","date_published":"2011-10-20","updated_at":"2026-11-27T04:35:36Z","subjects":["Aerospace Engineering","Mechanical Engineering","film cooling","flat plate","heat transfer","heat-flux","engine design","CFD","medium-duration","blowdown"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1315013452","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1315013452","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1315013452","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1315013452","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dunn, Michael"]},{"key":"dc:creator","label":"Author","values":["Davis, Shanon Marie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-10-20"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerospace Engineering","Mechanical Engineering","film cooling","flat plate","heat transfer","heat-flux","engine design","CFD","medium-duration","blowdown"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1315013452"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>For many years turbine designers have utilized advancements in film-cooling technology to allow for increased high-pressure turbine inlet temperature. Prediction tools, used to predict the cooling effectiveness of the representative cooling-hole and cooling-hole pattern designs have been successful in keeping the engines on wing for a large number of operational hours, but there is room for and a desire for improvement in the technology. Therefore, a study was undertaken at the OSU GTL to find a way to obtain basic data needed to help improve CFD prediction capability. The particular facility utilized for this work is a medium-duration blowdown facility to which significant improvements in the operational procedure of the cooling system have been made for the purposes of this work and both the facility and the improvements will be described in detail in this thesis. </p><p>In order to keep the CFD validation simple, a flat plate configuration with a realistic cooling hole pattern, representative of a high-pressure turbine blade for which measurements obtained as part of a full-stage experiment were obtained, was utilized along with flow properties of current interest to the industry. The measurements reported in this thesis yielded high response heat-flux measurements along the axial direction of the plate, including locations between the individual rows of cooling holes. The influence of Reynolds numbers on heat transfer to the plate was also explored. Lastly, the temperature of the main flow and the test section walls were varied to determine the effect of cooling on the local adiabatic wall temperature.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.121","7.92 MB"]},{"key":"dc:title","label":"Title","values":["Heat-Flux Measurements for a Realistic Cooling Hole Pattern and Different Flow Conditions"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dunn, Michael"],"dc:creator":["Davis, Shanon Marie"],"dc:date":["2011-10-20"],"dc:description":["<p>For many years turbine designers have utilized advancements in film-cooling technology to allow for increased high-pressure turbine inlet temperature. Prediction tools, used to predict the cooling effectiveness of the representative cooling-hole and cooling-hole pattern designs have been successful in keeping the engines on wing for a large number of operational hours, but there is room for and a desire for improvement in the technology. Therefore, a study was undertaken at the OSU GTL to find a way to obtain basic data needed to help improve CFD prediction capability. The particular facility utilized for this work is a medium-duration blowdown facility to which significant improvements in the operational procedure of the cooling system have been made for the purposes of this work and both the facility and the improvements will be described in detail in this thesis. </p><p>In order to keep the CFD validation simple, a flat plate configuration with a realistic cooling hole pattern, representative of a high-pressure turbine blade for which measurements obtained as part of a full-stage experiment were obtained, was utilized along with flow properties of current interest to the industry. The measurements reported in this thesis yielded high response heat-flux measurements along the axial direction of the plate, including locations between the individual rows of cooling holes. The influence of Reynolds numbers on heat transfer to the plate was also explored. Lastly, the temperature of the main flow and the test section walls were varied to determine the effect of cooling on the local adiabatic wall temperature.</p>"],"dc:format":["application/pdf","p.121","7.92 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1315013452"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Aerospace Engineering","Mechanical Engineering","film cooling","flat plate","heat transfer","heat-flux","engine design","CFD","medium-duration","blowdown"],"dc:title":["Heat-Flux Measurements for a Realistic Cooling Hole Pattern and Different Flow Conditions"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:36Z"}