{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1337742959"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1337742959","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Thermal Changes in the Dental Pulp During Er,Cr:YSGG Laser Removal of IPS e.max Press Lithium Disilicate Veneers","abstract":"<p>Background: Lasers have become an increasingly popular tool in the field of dentistry due their ability to perform a wide variety of both hard and soft tissue procedures. Recently it has been proposed that lasers may prove to be useful in the removal of some all-ceramic restorations, particularly veneers. The amount of temperature being generated intrapulpally during such a procedure has yet to be studied.</p><p>Methods: Thirty IPS e.max® Press lithium disilicate veneers were cemented to thirty extracted human premolars with Variolink® Veneer resin cement. Veneers were randomly divided into one of five groups, and scanned with an Er,Cr:YSGG laser at either 0W/0Hz, 25W/25Hz, 35W/25Hz, 25W/35Hz, or 35W/35Hz. During laser scanning, intrapulpal temperatures and debonding times were monitored.</p><p>Results: Increasing the laser wattage and/or pulse repetition rate resulted in an increase in the temperature generated intrapulpally. Increasing the wattage and/or decreasing the pulse repetition rate resulted in a reduced debonding time. At both 0W/0Hz and 23W/35Hz veneers we unable to be debonded.</p><p>Conclusions: The laser group at 2.5W/25Hz was the overall safest laser group studied. Based upon the results of this study, laser removal of ceramic veneers should be a safe procedure for the dental pulp if the correct laser settings are used.</p>","abstract_html":"&lt;p&gt;Background: Lasers have become an increasingly popular tool in the field of dentistry due their ability to perform a wide variety of both hard and soft tissue procedures. Recently it has been proposed that lasers may prove to be useful in the removal of some all-ceramic restorations, particularly veneers. The amount of temperature being generated intrapulpally during such a procedure has yet to be studied.&lt;/p&gt;&lt;p&gt;Methods: Thirty IPS e.max® Press lithium disilicate veneers were cemented to thirty extracted human premolars with Variolink® Veneer resin cement. Veneers were randomly divided into one of five groups, and scanned with an Er,Cr:YSGG laser at either 0W/0Hz, 25W/25Hz, 35W/25Hz, 25W/35Hz, or 35W/35Hz. During laser scanning, intrapulpal temperatures and debonding times were monitored.&lt;/p&gt;&lt;p&gt;Results: Increasing the laser wattage and/or pulse repetition rate resulted in an increase in the temperature generated intrapulpally. Increasing the wattage and/or decreasing the pulse repetition rate resulted in a reduced debonding time. At both 0W/0Hz and 23W/35Hz veneers we unable to be debonded.&lt;/p&gt;&lt;p&gt;Conclusions: The laser group at 2.5W/25Hz was the overall safest laser group studied. Based upon the results of this study, laser removal of ceramic veneers should be a safe procedure for the dental pulp if the correct laser settings are used.&lt;/p&gt;","abstract_has_math":false,"creators":["Phillips, Wesley B."],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":[],"advisors":["Peregrina, Alejandro"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06-22","date_published":"2012-06-22","updated_at":"2026-11-27T04:35:51Z","subjects":["Dental Care","Dentistry","Er,Cr:YSGG","laser","dental","pulp","veneer","debonding","removal","temperature","e.max"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1337742959","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1337742959","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1337742959","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1337742959","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peregrina, Alejandro"]},{"key":"dc:creator","label":"Author","values":["Phillips, Wesley B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-06-22"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dental Care","Dentistry","Er,Cr:YSGG","laser","dental","pulp","veneer","debonding","removal","temperature","e.max"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1337742959"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Background: Lasers have become an increasingly popular tool in the field of dentistry due their ability to perform a wide variety of both hard and soft tissue procedures. Recently it has been proposed that lasers may prove to be useful in the removal of some all-ceramic restorations, particularly veneers. The amount of temperature being generated intrapulpally during such a procedure has yet to be studied.</p><p>Methods: Thirty IPS e.max® Press lithium disilicate veneers were cemented to thirty extracted human premolars with Variolink® Veneer resin cement. Veneers were randomly divided into one of five groups, and scanned with an Er,Cr:YSGG laser at either 0W/0Hz, 25W/25Hz, 35W/25Hz, 25W/35Hz, or 35W/35Hz. During laser scanning, intrapulpal temperatures and debonding times were monitored.</p><p>Results: Increasing the laser wattage and/or pulse repetition rate resulted in an increase in the temperature generated intrapulpally. Increasing the wattage and/or decreasing the pulse repetition rate resulted in a reduced debonding time. At both 0W/0Hz and 23W/35Hz veneers we unable to be debonded.</p><p>Conclusions: The laser group at 2.5W/25Hz was the overall safest laser group studied. Based upon the results of this study, laser removal of ceramic veneers should be a safe procedure for the dental pulp if the correct laser settings are used.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.71","774.8 KB"]},{"key":"dc:title","label":"Title","values":["Thermal Changes in the Dental Pulp During Er,Cr:YSGG Laser Removal of IPS e.max Press Lithium Disilicate Veneers"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peregrina, Alejandro"],"dc:creator":["Phillips, Wesley B."],"dc:date":["2012-06-22"],"dc:description":["<p>Background: Lasers have become an increasingly popular tool in the field of dentistry due their ability to perform a wide variety of both hard and soft tissue procedures. Recently it has been proposed that lasers may prove to be useful in the removal of some all-ceramic restorations, particularly veneers. The amount of temperature being generated intrapulpally during such a procedure has yet to be studied.</p><p>Methods: Thirty IPS e.max® Press lithium disilicate veneers were cemented to thirty extracted human premolars with Variolink® Veneer resin cement. Veneers were randomly divided into one of five groups, and scanned with an Er,Cr:YSGG laser at either 0W/0Hz, 25W/25Hz, 35W/25Hz, 25W/35Hz, or 35W/35Hz. During laser scanning, intrapulpal temperatures and debonding times were monitored.</p><p>Results: Increasing the laser wattage and/or pulse repetition rate resulted in an increase in the temperature generated intrapulpally. Increasing the wattage and/or decreasing the pulse repetition rate resulted in a reduced debonding time. At both 0W/0Hz and 23W/35Hz veneers we unable to be debonded.</p><p>Conclusions: The laser group at 2.5W/25Hz was the overall safest laser group studied. Based upon the results of this study, laser removal of ceramic veneers should be a safe procedure for the dental pulp if the correct laser settings are used.</p>"],"dc:format":["application/pdf","p.71","774.8 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1337742959"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Dental Care","Dentistry","Er,Cr:YSGG","laser","dental","pulp","veneer","debonding","removal","temperature","e.max"],"dc:title":["Thermal Changes in the Dental Pulp During Er,Cr:YSGG Laser Removal of IPS e.max Press Lithium Disilicate Veneers"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:35:51Z"}