{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1343170555"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1343170555","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Comparison of the GiViTI Calibration Belt to Hosmer-Lemeshow Goodness of Fit","abstract":"The most commonly used method of determining calibration of logistic models is through the use of the Hosmer-Lemeshow goodness-of fit test (H-L test). However, a new method of calibration has been presented, known as the GiViTI Calibration Belt (GCB). Through the use of artificial and observational datasets from the GiViTI ICU study and from the Ohio State University Medical Center (OSUMC) patient readmission study, we present a comparison of the two methods of determining calibration. We have found that the GCB is most useful for identifying specific regions of miscalibration rather than an overall test of calibration. It is of particular importance in models where miscalibration is to be expected as it can identify regions of poor calibration due to insufficient numbers of observations. In models that are properly calibrated, the GCB matches the H-L test in concluding that there are no major regions of miscalibration regardless of the number of observations the model is based upon. The GCB shows promise as a tool for recalibrating models to adjust for changes in hospital practices that may have occurred after the model’s development.","abstract_html":"The most commonly used method of determining calibration of logistic models is through the use of the Hosmer-Lemeshow goodness-of fit test (H-L test). However, a new method of calibration has been presented, known as the GiViTI Calibration Belt (GCB). Through the use of artificial and observational datasets from the GiViTI ICU study and from the Ohio State University Medical Center (OSUMC) patient readmission study, we present a comparison of the two methods of determining calibration. We have found that the GCB is most useful for identifying specific regions of miscalibration rather than an overall test of calibration. It is of particular importance in models where miscalibration is to be expected as it can identify regions of poor calibration due to insufficient numbers of observations. In models that are properly calibrated, the GCB matches the H-L test in concluding that there are no major regions of miscalibration regardless of the number of observations the model is based upon. The GCB shows promise as a tool for recalibrating models to adjust for changes in hospital practices that may have occurred after the model’s development.","abstract_has_math":false,"creators":["Wasserman, Jared Robert"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Public Health","degree_department":null,"school":null,"contributors":[],"advisors":["Lemeshow, Stanley"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08-16","date_published":"2012-08-16","updated_at":"2026-11-27T04:36:00Z","subjects":["Biostatistics","calibration","hosmer-lemeshow","goodness of fit"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1343170555","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1343170555","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1343170555","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1343170555","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lemeshow, Stanley"]},{"key":"dc:creator","label":"Author","values":["Wasserman, Jared Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-08-16"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Public Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biostatistics","calibration","hosmer-lemeshow","goodness of fit"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1343170555"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The most commonly used method of determining calibration of logistic models is through the use of the Hosmer-Lemeshow goodness-of fit test (H-L test). However, a new method of calibration has been presented, known as the GiViTI Calibration Belt (GCB). Through the use of artificial and observational datasets from the GiViTI ICU study and from the Ohio State University Medical Center (OSUMC) patient readmission study, we present a comparison of the two methods of determining calibration. We have found that the GCB is most useful for identifying specific regions of miscalibration rather than an overall test of calibration. It is of particular importance in models where miscalibration is to be expected as it can identify regions of poor calibration due to insufficient numbers of observations. In models that are properly calibrated, the GCB matches the H-L test in concluding that there are no major regions of miscalibration regardless of the number of observations the model is based upon. The GCB shows promise as a tool for recalibrating models to adjust for changes in hospital practices that may have occurred after the model’s development."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.28","694.2 KB"]},{"key":"dc:title","label":"Title","values":["A Comparison of the GiViTI Calibration Belt to Hosmer-Lemeshow Goodness of Fit"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lemeshow, Stanley"],"dc:creator":["Wasserman, Jared Robert"],"dc:date":["2012-08-16"],"dc:description":["The most commonly used method of determining calibration of logistic models is through the use of the Hosmer-Lemeshow goodness-of fit test (H-L test). However, a new method of calibration has been presented, known as the GiViTI Calibration Belt (GCB). Through the use of artificial and observational datasets from the GiViTI ICU study and from the Ohio State University Medical Center (OSUMC) patient readmission study, we present a comparison of the two methods of determining calibration. We have found that the GCB is most useful for identifying specific regions of miscalibration rather than an overall test of calibration. It is of particular importance in models where miscalibration is to be expected as it can identify regions of poor calibration due to insufficient numbers of observations. In models that are properly calibrated, the GCB matches the H-L test in concluding that there are no major regions of miscalibration regardless of the number of observations the model is based upon. The GCB shows promise as a tool for recalibrating models to adjust for changes in hospital practices that may have occurred after the model’s development."],"dc:format":["application/pdf","p.28","694.2 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1343170555"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biostatistics","calibration","hosmer-lemeshow","goodness of fit"],"dc:title":["A Comparison of the GiViTI Calibration Belt to Hosmer-Lemeshow Goodness of Fit"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Public Health"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:36:00Z"}