{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1372104885"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1372104885","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Antibody/Cell Binding and Magnetic Transport in a Microfluidic Device","abstract":"The advancement of micro-total analysis systems is increasing the ability to perform multiple functions in one microfluidic device. These systems have several advantages in biomedical applications, including lower equipment and personnel costs, reduced power requirements, faster separations, and smaller sample and reagent volume requirements. Because of this, there has been a growing interest in the study of particle motion in micro and nanochannels. The Automated Cell to Biomolecule Analysis (ACBA) device labels, sorts, and analyzes cancer cells in an enriched blood sample. Understanding transport methods and the behaviour of particles in microfluidic lab-on-a-chip or micro-total analysis systems is important to the advancement of system applications.Stochastic equations are used to characterize magnetic microbead motion, and the effect of the Stokes drag force on magnetic microbeads is analyzed. Stochastic differential equations specifically the Langevin and Fokker-Planck equations are used to characterize the probability density distribution of a microbead in a microfluidic channel. The results show that due to the size of the microbead these equations the binding probability of a magnetic microbead to a circulating tumor cell. However the results do indicate that under different conditions the probability equation can be used if the Peclet number, Pe = 10 100.The capture area of a magnetic microbead with and without a cell attached to it is analyzed to see if the effect of the change of Stokes drag force on the magnetic microbead effects the magnetic capture area. It is concluded that the added drag from the attached circulating tumor cell does in fact affect the capture area of the magnetic microbead in the presence of a magnetic with a constant magnetic field.","abstract_html":"The advancement of micro-total analysis systems is increasing the ability to perform multiple functions in one microfluidic device. These systems have several advantages in biomedical applications, including lower equipment and personnel costs, reduced power requirements, faster separations, and smaller sample and reagent volume requirements. Because of this, there has been a growing interest in the study of particle motion in micro and nanochannels. The Automated Cell to Biomolecule Analysis (ACBA) device labels, sorts, and analyzes cancer cells in an enriched blood sample. Understanding transport methods and the behaviour of particles in microfluidic lab-on-a-chip or micro-total analysis systems is important to the advancement of system applications.Stochastic equations are used to characterize magnetic microbead motion, and the effect of the Stokes drag force on magnetic microbeads is analyzed. Stochastic differential equations specifically the Langevin and Fokker-Planck equations are used to characterize the probability density distribution of a microbead in a microfluidic channel. The results show that due to the size of the microbead these equations the binding probability of a magnetic microbead to a circulating tumor cell. However the results do indicate that under different conditions the probability equation can be used if the Peclet number, Pe = 10 100.The capture area of a magnetic microbead with and without a cell attached to it is analyzed to see if the effect of the change of Stokes drag force on the magnetic microbead effects the magnetic capture area. It is concluded that the added drag from the attached circulating tumor cell does in fact affect the capture area of the magnetic microbead in the presence of a magnetic with a constant magnetic field.","abstract_has_math":false,"creators":["Adams, Shauna"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Conlisk, A. T"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-08-29","date_published":"2013-08-29","updated_at":"2026-11-27T04:12:58Z","subjects":["Mechanical Engineering","Electromagnetism","Mathematics","Microfluidics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1372104885","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1372104885","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1372104885","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1372104885","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Conlisk, A. T"]},{"key":"dc:creator","label":"Author","values":["Adams, Shauna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-08-29"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Electromagnetism","Mathematics","Microfluidics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1372104885"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The advancement of micro-total analysis systems is increasing the ability to perform multiple functions in one microfluidic device. These systems have several advantages in biomedical applications, including lower equipment and personnel costs, reduced power requirements, faster separations, and smaller sample and reagent volume requirements. Because of this, there has been a growing interest in the study of particle motion in micro and nanochannels. The Automated Cell to Biomolecule Analysis (ACBA) device labels, sorts, and analyzes cancer cells in an enriched blood sample. Understanding transport methods and the behaviour of particles in microfluidic lab-on-a-chip or micro-total analysis systems is important to the advancement of system applications.Stochastic equations are used to characterize magnetic microbead motion, and the effect of the Stokes drag force on magnetic microbeads is analyzed. Stochastic differential equations specifically the Langevin and Fokker-Planck equations are used to characterize the probability density distribution of a microbead in a microfluidic channel. The results show that due to the size of the microbead these equations the binding probability of a magnetic microbead to a circulating tumor cell. However the results do indicate that under different conditions the probability equation can be used if the Peclet number, Pe = 10 100.The capture area of a magnetic microbead with and without a cell attached to it is analyzed to see if the effect of the change of Stokes drag force on the magnetic microbead effects the magnetic capture area. It is concluded that the added drag from the attached circulating tumor cell does in fact affect the capture area of the magnetic microbead in the presence of a magnetic with a constant magnetic field."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.55 MB"]},{"key":"dc:title","label":"Title","values":["Antibody/Cell Binding and Magnetic Transport in a Microfluidic Device"]}]}],"canonical_facts":{"dc:contributor.advisor":["Conlisk, A. T"],"dc:creator":["Adams, Shauna"],"dc:date":["2013-08-29"],"dc:description":["The advancement of micro-total analysis systems is increasing the ability to perform multiple functions in one microfluidic device. These systems have several advantages in biomedical applications, including lower equipment and personnel costs, reduced power requirements, faster separations, and smaller sample and reagent volume requirements. Because of this, there has been a growing interest in the study of particle motion in micro and nanochannels. The Automated Cell to Biomolecule Analysis (ACBA) device labels, sorts, and analyzes cancer cells in an enriched blood sample. Understanding transport methods and the behaviour of particles in microfluidic lab-on-a-chip or micro-total analysis systems is important to the advancement of system applications.Stochastic equations are used to characterize magnetic microbead motion, and the effect of the Stokes drag force on magnetic microbeads is analyzed. Stochastic differential equations specifically the Langevin and Fokker-Planck equations are used to characterize the probability density distribution of a microbead in a microfluidic channel. The results show that due to the size of the microbead these equations the binding probability of a magnetic microbead to a circulating tumor cell. However the results do indicate that under different conditions the probability equation can be used if the Peclet number, Pe = 10 100.The capture area of a magnetic microbead with and without a cell attached to it is analyzed to see if the effect of the change of Stokes drag force on the magnetic microbead effects the magnetic capture area. It is concluded that the added drag from the attached circulating tumor cell does in fact affect the capture area of the magnetic microbead in the presence of a magnetic with a constant magnetic field."],"dc:format":["application/pdf","1.55 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1372104885"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Electromagnetism","Mathematics","Microfluidics"],"dc:title":["Antibody/Cell Binding and Magnetic Transport in a Microfluidic Device"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:12:58Z"}