{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1388356167"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1388356167","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Gas Tungsten Arc Welding of 304L and 21-6-9 Austenitic Stainless Steel with Penetration Enhancing Compounds","abstract":"The penetration capability of gas tungsten arc (GTA) welding of stainless steels is influenced greatly by small amounts of trace elements, such as sulfur and oxygen. Due to the small amounts of sulfur in modern austenitic stainless steels, a shallow weld penetration occurs through a surface tension related phenomena, known as the Marangoni effect. Increasing the penetration efficiency and reducing variations of GTA welds has been investigated since the 1960s using a number of different oxide combinations including the three used in this study; TiO2, SiO2, and Cr2O3. ASM has identified these oxides as penetration enhancing compounds (PEC) and the process has been given the name A-TIG or activated TIG. The use of PECs has been shown to increase penetration in GTA welding through arc constriction and surface tension driven fluid flow resulting in a favorable Marangoni effect for penetration. The process of adding PECs to the GTA welding process has relied upon a paint based application method requiring additional processing steps and adequate use of quality control methods to maintain paint deposition consistency. Precise control is necessary to reduce the amount of weld penetration variability. The development of a 308L composition PEC cored wire eliminates the additional steps required during setup of the paint on process, and allows for consistent weld pool application.A comprehensive analysis of the A-TIG process and microstructure of welds with PEC additions were evaluated using 304L and 21-6-9 base materials. PEC flux cored wire of 0.045 inch diameter was used along with 308L solid wire for comparison of weld microstructures. A small loss in penetration capability with the use of cored wire was surpassed through ease of application. A penetration enhancement of 293% was measured in welds of low sulfur 304L. A single pass, full penetration tube weld on 304L of 3/8 inch wall thickness was successfully developed. Internal pressurization of the backing gas was required and achieved using a multi-stage pressure regulator on the supply of argon, with a back pressure regulator and Magnehelic gauge on the exit side of the weld purge system. A back pressure of 3 to 5 inches of water column (InWC) was required to support the 3/8 inch full penetration weld puddle in the weld joint.Microstructural analysis of the resultant welds was completed using standard metallographic preparation techniques various etching techniques. Optical microscopy, macro and micro hardness indentations, as well as ferrite content analyses were used to examine the welds. Advanced microscopy and chemical analysis techniques were also used, including scanning electron microscopy, electron dispersive spectroscopy and laser ablation mass spectroscopy. Increased alloying of PEC constituents in full penetration welds resulted in a max of 0.78 wt% titanium measured at the root of the weld. Partial penetration welds of similar heat input have reduced alloying of PEC constituents resulting in a max of 0.03 wt% titanium. The entrapment of slag elements or formations of intermetallic compounds were not seen in welds with PEC addition.","abstract_html":"The penetration capability of gas tungsten arc (GTA) welding of stainless steels is influenced greatly by small amounts of trace elements, such as sulfur and oxygen. Due to the small amounts of sulfur in modern austenitic stainless steels, a shallow weld penetration occurs through a surface tension related phenomena, known as the Marangoni effect. Increasing the penetration efficiency and reducing variations of GTA welds has been investigated since the 1960s using a number of different oxide combinations including the three used in this study; TiO2, SiO2, and Cr2O3. ASM has identified these oxides as penetration enhancing compounds (PEC) and the process has been given the name A-TIG or activated TIG. The use of PECs has been shown to increase penetration in GTA welding through arc constriction and surface tension driven fluid flow resulting in a favorable Marangoni effect for penetration. The process of adding PECs to the GTA welding process has relied upon a paint based application method requiring additional processing steps and adequate use of quality control methods to maintain paint deposition consistency. Precise control is necessary to reduce the amount of weld penetration variability. The development of a 308L composition PEC cored wire eliminates the additional steps required during setup of the paint on process, and allows for consistent weld pool application.A comprehensive analysis of the A-TIG process and microstructure of welds with PEC additions were evaluated using 304L and 21-6-9 base materials. PEC flux cored wire of 0.045 inch diameter was used along with 308L solid wire for comparison of weld microstructures. A small loss in penetration capability with the use of cored wire was surpassed through ease of application. A penetration enhancement of 293% was measured in welds of low sulfur 304L. A single pass, full penetration tube weld on 304L of 3/8 inch wall thickness was successfully developed. Internal pressurization of the backing gas was required and achieved using a multi-stage pressure regulator on the supply of argon, with a back pressure regulator and Magnehelic gauge on the exit side of the weld purge system. A back pressure of 3 to 5 inches of water column (InWC) was required to support the 3/8 inch full penetration weld puddle in the weld joint.Microstructural analysis of the resultant welds was completed using standard metallographic preparation techniques various etching techniques. Optical microscopy, macro and micro hardness indentations, as well as ferrite content analyses were used to examine the welds. Advanced microscopy and chemical analysis techniques were also used, including scanning electron microscopy, electron dispersive spectroscopy and laser ablation mass spectroscopy. Increased alloying of PEC constituents in full penetration welds resulted in a max of 0.78 wt% titanium measured at the root of the weld. Partial penetration welds of similar heat input have reduced alloying of PEC constituents resulting in a max of 0.03 wt% titanium. The entrapment of slag elements or formations of intermetallic compounds were not seen in welds with PEC addition.","abstract_has_math":false,"creators":["Faraone, Kevin Michael"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Lippold, John"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-06-02","date_published":"2014-06-02","updated_at":"2026-11-27T04:39:15Z","subjects":["Engineering","GTA, TIG, A-TIG, PEC, Austenitic Stainless Steel, Welding, Weld Variability, PEC Cored Wire"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1388356167","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1388356167","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1388356167","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1388356167","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lippold, John"]},{"key":"dc:creator","label":"Author","values":["Faraone, Kevin Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-06-02"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","GTA, TIG, A-TIG, PEC, Austenitic Stainless Steel, Welding, Weld Variability, PEC Cored Wire"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1388356167"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The penetration capability of gas tungsten arc (GTA) welding of stainless steels is influenced greatly by small amounts of trace elements, such as sulfur and oxygen. Due to the small amounts of sulfur in modern austenitic stainless steels, a shallow weld penetration occurs through a surface tension related phenomena, known as the Marangoni effect. Increasing the penetration efficiency and reducing variations of GTA welds has been investigated since the 1960s using a number of different oxide combinations including the three used in this study; TiO2, SiO2, and Cr2O3. ASM has identified these oxides as penetration enhancing compounds (PEC) and the process has been given the name A-TIG or activated TIG. The use of PECs has been shown to increase penetration in GTA welding through arc constriction and surface tension driven fluid flow resulting in a favorable Marangoni effect for penetration. The process of adding PECs to the GTA welding process has relied upon a paint based application method requiring additional processing steps and adequate use of quality control methods to maintain paint deposition consistency. Precise control is necessary to reduce the amount of weld penetration variability. The development of a 308L composition PEC cored wire eliminates the additional steps required during setup of the paint on process, and allows for consistent weld pool application.A comprehensive analysis of the A-TIG process and microstructure of welds with PEC additions were evaluated using 304L and 21-6-9 base materials. PEC flux cored wire of 0.045 inch diameter was used along with 308L solid wire for comparison of weld microstructures. A small loss in penetration capability with the use of cored wire was surpassed through ease of application. A penetration enhancement of 293% was measured in welds of low sulfur 304L. A single pass, full penetration tube weld on 304L of 3/8 inch wall thickness was successfully developed. Internal pressurization of the backing gas was required and achieved using a multi-stage pressure regulator on the supply of argon, with a back pressure regulator and Magnehelic gauge on the exit side of the weld purge system. A back pressure of 3 to 5 inches of water column (InWC) was required to support the 3/8 inch full penetration weld puddle in the weld joint.Microstructural analysis of the resultant welds was completed using standard metallographic preparation techniques various etching techniques. Optical microscopy, macro and micro hardness indentations, as well as ferrite content analyses were used to examine the welds. Advanced microscopy and chemical analysis techniques were also used, including scanning electron microscopy, electron dispersive spectroscopy and laser ablation mass spectroscopy. Increased alloying of PEC constituents in full penetration welds resulted in a max of 0.78 wt% titanium measured at the root of the weld. Partial penetration welds of similar heat input have reduced alloying of PEC constituents resulting in a max of 0.03 wt% titanium. The entrapment of slag elements or formations of intermetallic compounds were not seen in welds with PEC addition."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.218","23.32 MB"]},{"key":"dc:title","label":"Title","values":["Gas Tungsten Arc Welding of 304L and 21-6-9 Austenitic Stainless Steel with Penetration Enhancing Compounds"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lippold, John"],"dc:creator":["Faraone, Kevin Michael"],"dc:date":["2014-06-02"],"dc:description":["The penetration capability of gas tungsten arc (GTA) welding of stainless steels is influenced greatly by small amounts of trace elements, such as sulfur and oxygen. Due to the small amounts of sulfur in modern austenitic stainless steels, a shallow weld penetration occurs through a surface tension related phenomena, known as the Marangoni effect. Increasing the penetration efficiency and reducing variations of GTA welds has been investigated since the 1960s using a number of different oxide combinations including the three used in this study; TiO2, SiO2, and Cr2O3. ASM has identified these oxides as penetration enhancing compounds (PEC) and the process has been given the name A-TIG or activated TIG. The use of PECs has been shown to increase penetration in GTA welding through arc constriction and surface tension driven fluid flow resulting in a favorable Marangoni effect for penetration. The process of adding PECs to the GTA welding process has relied upon a paint based application method requiring additional processing steps and adequate use of quality control methods to maintain paint deposition consistency. Precise control is necessary to reduce the amount of weld penetration variability. The development of a 308L composition PEC cored wire eliminates the additional steps required during setup of the paint on process, and allows for consistent weld pool application.A comprehensive analysis of the A-TIG process and microstructure of welds with PEC additions were evaluated using 304L and 21-6-9 base materials. PEC flux cored wire of 0.045 inch diameter was used along with 308L solid wire for comparison of weld microstructures. A small loss in penetration capability with the use of cored wire was surpassed through ease of application. A penetration enhancement of 293% was measured in welds of low sulfur 304L. A single pass, full penetration tube weld on 304L of 3/8 inch wall thickness was successfully developed. Internal pressurization of the backing gas was required and achieved using a multi-stage pressure regulator on the supply of argon, with a back pressure regulator and Magnehelic gauge on the exit side of the weld purge system. A back pressure of 3 to 5 inches of water column (InWC) was required to support the 3/8 inch full penetration weld puddle in the weld joint.Microstructural analysis of the resultant welds was completed using standard metallographic preparation techniques various etching techniques. Optical microscopy, macro and micro hardness indentations, as well as ferrite content analyses were used to examine the welds. Advanced microscopy and chemical analysis techniques were also used, including scanning electron microscopy, electron dispersive spectroscopy and laser ablation mass spectroscopy. Increased alloying of PEC constituents in full penetration welds resulted in a max of 0.78 wt% titanium measured at the root of the weld. Partial penetration welds of similar heat input have reduced alloying of PEC constituents resulting in a max of 0.03 wt% titanium. The entrapment of slag elements or formations of intermetallic compounds were not seen in welds with PEC addition."],"dc:format":["application/pdf","p.218","23.32 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1388356167"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","GTA, TIG, A-TIG, PEC, Austenitic Stainless Steel, Welding, Weld Variability, PEC Cored Wire"],"dc:title":["Gas Tungsten Arc Welding of 304L and 21-6-9 Austenitic Stainless Steel with Penetration Enhancing Compounds"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:39:15Z"}