{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1398696323"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1398696323","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"EFFECTIVENESS OF PRE-RINSE DURING IN-PLACE CLEANING OF STAINLESS STEEL PIPE LINES","abstract":"Clean-In-Place (CIP) is a widely-used process that provides a high level of repeatability and safety with a lower labor cost. The high consumption of water and energy used with current CIP methods places an economic and ecologic stress on industry. The objective of this study was to measure the parameters of CIP pre-rinse (flow rate, flow temperature and contact time) and the impact of each on effectiveness of cleaning, then develop recommendations on the parameters needed to achieve rinse effectiveness while reducing water and energy demands. A pilot-scale CIP system was operated under combinations of the parameters to clean stainless steel pipes soiled by reconstituted skim milk. Rinse effectiveness was quantified by comparing the protein content remaining on pipe surface after pre-rinse with the initial protein content. The rinse effectiveness of pre-rinse varied from 70% to 95%. High velocity was linked to a higher level of rinse effectiveness. Increasing temperature from 23C to 45C improved rinse effectiveness dramatically (P<0.05). However, this trend was less obvious when the temperature was increased to 67C. Similarly, extending the contact time provided no improvement on rinse effectiveness under high temperature and high velocity. The water efficiency sharply decreased within the launching phase of pre-rinse. The parameters used in this study indicate the limit of CIP pre-rinse effectiveness are due to the strong molecule-surface binding of the milk soil which could not be removed completely by water alone. This study shows that optimization of CIP pre-rinse time, flow and temperature parameters is a viable approach to reduce water and energy costs.","abstract_html":"Clean-In-Place (CIP) is a widely-used process that provides a high level of repeatability and safety with a lower labor cost. The high consumption of water and energy used with current CIP methods places an economic and ecologic stress on industry. The objective of this study was to measure the parameters of CIP pre-rinse (flow rate, flow temperature and contact time) and the impact of each on effectiveness of cleaning, then develop recommendations on the parameters needed to achieve rinse effectiveness while reducing water and energy demands. A pilot-scale CIP system was operated under combinations of the parameters to clean stainless steel pipes soiled by reconstituted skim milk. Rinse effectiveness was quantified by comparing the protein content remaining on pipe surface after pre-rinse with the initial protein content. The rinse effectiveness of pre-rinse varied from 70% to 95%. High velocity was linked to a higher level of rinse effectiveness. Increasing temperature from 23C to 45C improved rinse effectiveness dramatically (P&lt;0.05). However, this trend was less obvious when the temperature was increased to 67C. Similarly, extending the contact time provided no improvement on rinse effectiveness under high temperature and high velocity. The water efficiency sharply decreased within the launching phase of pre-rinse. The parameters used in this study indicate the limit of CIP pre-rinse effectiveness are due to the strong molecule-surface binding of the milk soil which could not be removed completely by water alone. This study shows that optimization of CIP pre-rinse time, flow and temperature parameters is a viable approach to reduce water and energy costs.","abstract_has_math":false,"creators":["Fan, Mengyuan"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Food Science and Technology","degree_department":null,"school":null,"contributors":[],"advisors":["heldman, dennis"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-10-02","date_published":"2014-10-02","updated_at":"2026-11-27T04:39:37Z","subjects":["Food Science","clean-in-place, stainless steel, milk deposit"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1398696323","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1398696323","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1398696323","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1398696323","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["heldman, dennis"]},{"key":"dc:creator","label":"Author","values":["Fan, Mengyuan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-10-02"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Food Science and Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Food Science","clean-in-place, stainless steel, milk deposit"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1398696323"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Clean-In-Place (CIP) is a widely-used process that provides a high level of repeatability and safety with a lower labor cost. The high consumption of water and energy used with current CIP methods places an economic and ecologic stress on industry. The objective of this study was to measure the parameters of CIP pre-rinse (flow rate, flow temperature and contact time) and the impact of each on effectiveness of cleaning, then develop recommendations on the parameters needed to achieve rinse effectiveness while reducing water and energy demands. A pilot-scale CIP system was operated under combinations of the parameters to clean stainless steel pipes soiled by reconstituted skim milk. Rinse effectiveness was quantified by comparing the protein content remaining on pipe surface after pre-rinse with the initial protein content. The rinse effectiveness of pre-rinse varied from 70% to 95%. High velocity was linked to a higher level of rinse effectiveness. Increasing temperature from 23C to 45C improved rinse effectiveness dramatically (P<0.05). However, this trend was less obvious when the temperature was increased to 67C. Similarly, extending the contact time provided no improvement on rinse effectiveness under high temperature and high velocity. The water efficiency sharply decreased within the launching phase of pre-rinse. The parameters used in this study indicate the limit of CIP pre-rinse effectiveness are due to the strong molecule-surface binding of the milk soil which could not be removed completely by water alone. This study shows that optimization of CIP pre-rinse time, flow and temperature parameters is a viable approach to reduce water and energy costs."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.94","1.69 MB"]},{"key":"dc:title","label":"Title","values":["EFFECTIVENESS OF PRE-RINSE DURING IN-PLACE CLEANING OF STAINLESS STEEL PIPE LINES"]}]}],"canonical_facts":{"dc:contributor.advisor":["heldman, dennis"],"dc:creator":["Fan, Mengyuan"],"dc:date":["2014-10-02"],"dc:description":["Clean-In-Place (CIP) is a widely-used process that provides a high level of repeatability and safety with a lower labor cost. The high consumption of water and energy used with current CIP methods places an economic and ecologic stress on industry. The objective of this study was to measure the parameters of CIP pre-rinse (flow rate, flow temperature and contact time) and the impact of each on effectiveness of cleaning, then develop recommendations on the parameters needed to achieve rinse effectiveness while reducing water and energy demands. A pilot-scale CIP system was operated under combinations of the parameters to clean stainless steel pipes soiled by reconstituted skim milk. Rinse effectiveness was quantified by comparing the protein content remaining on pipe surface after pre-rinse with the initial protein content. The rinse effectiveness of pre-rinse varied from 70% to 95%. High velocity was linked to a higher level of rinse effectiveness. Increasing temperature from 23C to 45C improved rinse effectiveness dramatically (P<0.05). However, this trend was less obvious when the temperature was increased to 67C. Similarly, extending the contact time provided no improvement on rinse effectiveness under high temperature and high velocity. The water efficiency sharply decreased within the launching phase of pre-rinse. The parameters used in this study indicate the limit of CIP pre-rinse effectiveness are due to the strong molecule-surface binding of the milk soil which could not be removed completely by water alone. This study shows that optimization of CIP pre-rinse time, flow and temperature parameters is a viable approach to reduce water and energy costs."],"dc:format":["application/pdf","p.94","1.69 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1398696323"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Food Science","clean-in-place, stainless steel, milk deposit"],"dc:title":["EFFECTIVENESS OF PRE-RINSE DURING IN-PLACE CLEANING OF STAINLESS STEEL PIPE LINES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Food Science and Technology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:39:37Z"}