{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1430747355"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1430747355","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Dynamic Moments on the Cervical Spine Imposed by Head-Mounted Equipment","abstract":"Head-mounted equipment has been suggested as a risk factor for cervical spine disorders (CSDs), but the dynamic effects of wearing head-mounted equipment under non-impulse conditions have not yet been modelled biomechanically. The goal of this research was to evaluate the relative risk of CSDs associated with some common head-mounted equipment configurations worn by pararescue jumpers (PJs).Twenty-four male subjects completed six different head-motion tasks while wearing each of six different equipment configurations. Optical motion capture (MOCAP) was used to quantify the motion and drive a biomechanical model, from which exposed moments could be derived.The addition of head-mounted equipment always led to an increase in resultant moment over wearing no equipment, up to 106%. The minimal equipment accounted for (56-95%) of the total increase in load, with NVG (and associated batteries, if any) accounting for the remainder. When subjects were required to look through the NVG, sagittal flexion on certain tasks increased by up to 14 degrees.There is evidence that the risk of CSDs is increased as a result of wearing head-mounted equipment, and that these risks could potentially be reduced by modifying the head-mounted equipment. The results of this study can inform the development of head-mounted equipment. A multitude of other tasks could be evaluated with respect to risk of CSDs using this technique.","abstract_html":"Head-mounted equipment has been suggested as a risk factor for cervical spine disorders (CSDs), but the dynamic effects of wearing head-mounted equipment under non-impulse conditions have not yet been modelled biomechanically. The goal of this research was to evaluate the relative risk of CSDs associated with some common head-mounted equipment configurations worn by pararescue jumpers (PJs).Twenty-four male subjects completed six different head-motion tasks while wearing each of six different equipment configurations. Optical motion capture (MOCAP) was used to quantify the motion and drive a biomechanical model, from which exposed moments could be derived.The addition of head-mounted equipment always led to an increase in resultant moment over wearing no equipment, up to 106%. The minimal equipment accounted for (56-95%) of the total increase in load, with NVG (and associated batteries, if any) accounting for the remainder. When subjects were required to look through the NVG, sagittal flexion on certain tasks increased by up to 14 degrees.There is evidence that the risk of CSDs is increased as a result of wearing head-mounted equipment, and that these risks could potentially be reduced by modifying the head-mounted equipment. The results of this study can inform the development of head-mounted equipment. A multitude of other tasks could be evaluated with respect to risk of CSDs using this technique.","abstract_has_math":false,"creators":["Aurand, Alexander M."],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Industrial and Systems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Marras, William"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-08-27","date_published":"2015-08-27","updated_at":"2026-11-27T04:40:22Z","subjects":["Aerospace Engineering","Armed Forces","Biomechanics","Engineering","Environmental Health","Industrial Engineering","Kinesiology","Occupational Health","Occupational Safety","biomechanics, cervical spine, risk, neck, moment, load, helmet, night vision goggles, NVG, head-mounted equipment"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1430747355","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1430747355","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1430747355","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1430747355","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marras, William"]},{"key":"dc:creator","label":"Author","values":["Aurand, Alexander M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-08-27"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerospace Engineering","Armed Forces","Biomechanics","Engineering","Environmental Health","Industrial Engineering","Kinesiology","Occupational Health","Occupational Safety","biomechanics, cervical spine, risk, neck, moment, load, helmet, night vision goggles, NVG, head-mounted equipment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1430747355"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Head-mounted equipment has been suggested as a risk factor for cervical spine disorders (CSDs), but the dynamic effects of wearing head-mounted equipment under non-impulse conditions have not yet been modelled biomechanically. The goal of this research was to evaluate the relative risk of CSDs associated with some common head-mounted equipment configurations worn by pararescue jumpers (PJs).Twenty-four male subjects completed six different head-motion tasks while wearing each of six different equipment configurations. Optical motion capture (MOCAP) was used to quantify the motion and drive a biomechanical model, from which exposed moments could be derived.The addition of head-mounted equipment always led to an increase in resultant moment over wearing no equipment, up to 106%. The minimal equipment accounted for (56-95%) of the total increase in load, with NVG (and associated batteries, if any) accounting for the remainder. When subjects were required to look through the NVG, sagittal flexion on certain tasks increased by up to 14 degrees.There is evidence that the risk of CSDs is increased as a result of wearing head-mounted equipment, and that these risks could potentially be reduced by modifying the head-mounted equipment. The results of this study can inform the development of head-mounted equipment. A multitude of other tasks could be evaluated with respect to risk of CSDs using this technique."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.85","2.65 MB"]},{"key":"dc:title","label":"Title","values":["Dynamic Moments on the Cervical Spine Imposed by Head-Mounted Equipment"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marras, William"],"dc:creator":["Aurand, Alexander M."],"dc:date":["2015-08-27"],"dc:description":["Head-mounted equipment has been suggested as a risk factor for cervical spine disorders (CSDs), but the dynamic effects of wearing head-mounted equipment under non-impulse conditions have not yet been modelled biomechanically. The goal of this research was to evaluate the relative risk of CSDs associated with some common head-mounted equipment configurations worn by pararescue jumpers (PJs).Twenty-four male subjects completed six different head-motion tasks while wearing each of six different equipment configurations. Optical motion capture (MOCAP) was used to quantify the motion and drive a biomechanical model, from which exposed moments could be derived.The addition of head-mounted equipment always led to an increase in resultant moment over wearing no equipment, up to 106%. The minimal equipment accounted for (56-95%) of the total increase in load, with NVG (and associated batteries, if any) accounting for the remainder. When subjects were required to look through the NVG, sagittal flexion on certain tasks increased by up to 14 degrees.There is evidence that the risk of CSDs is increased as a result of wearing head-mounted equipment, and that these risks could potentially be reduced by modifying the head-mounted equipment. The results of this study can inform the development of head-mounted equipment. A multitude of other tasks could be evaluated with respect to risk of CSDs using this technique."],"dc:format":["application/pdf","p.85","2.65 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1430747355"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Aerospace Engineering","Armed Forces","Biomechanics","Engineering","Environmental Health","Industrial Engineering","Kinesiology","Occupational Health","Occupational Safety","biomechanics, cervical spine, risk, neck, moment, load, helmet, night vision goggles, NVG, head-mounted equipment"],"dc:title":["Dynamic Moments on the Cervical Spine Imposed by Head-Mounted Equipment"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Industrial and Systems Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:40:22Z"}