{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1440451065"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1440451065","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Wastewater Reuse: Comprehensive Study about Treatment System Efficiency and Potential Public Health Concerns","abstract":"One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat wastewater while minimizing the public health risks and the contamination of water resources in rural areas not only of Ohio, but also of regions with the similar climate and soil conditions across the world.","abstract_html":"One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat wastewater while minimizing the public health risks and the contamination of water resources in rural areas not only of Ohio, but also of regions with the similar climate and soil conditions across the world.","abstract_has_math":false,"creators":["Park, Eunyoung"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Public Health","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Lee, Jiyoung","Mancl, Karen"],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-27T04:40:38Z","subjects":["Environmental Health","Public Health","Water Resource Management","Wastewater reuse","soil","groundwater","onsite wastewater reuse system","batch chlorination","peat biotreatment","pathogen removal","coliphage","Clostridium perfringens"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1440451065","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1440451065","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1440451065","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1440451065","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Lee, Jiyoung","Mancl, Karen"]},{"key":"dc:creator","label":"Author","values":["Park, Eunyoung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Public Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Environmental Health","Public Health","Water Resource Management","Wastewater reuse","soil","groundwater","onsite wastewater reuse system","batch chlorination","peat biotreatment","pathogen removal","coliphage","Clostridium perfringens"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1440451065"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat wastewater while minimizing the public health risks and the contamination of water resources in rural areas not only of Ohio, but also of regions with the similar climate and soil conditions across the world."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.151","1.87 MB"]},{"key":"dc:title","label":"Title","values":["Wastewater Reuse: Comprehensive Study about Treatment System Efficiency and Potential Public Health Concerns"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Lee, Jiyoung","Mancl, Karen"],"dc:creator":["Park, Eunyoung"],"dc:date":["2015"],"dc:description":["One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat One important ecosystem service of soil is water purification. Soil-based septic systems serve 25 % of population in US. Climatic factors and soil condition play a significant role in functioning such systems. Shallow depths and seasonal saturation characterized by US Midwest soils raise the concern in using shallow soils for treating wastewater. Ohio Department of Health sets the requirement of the soil depth as little as 15 cm (6 inches) to treat wastewater containing at least 103 coliform CFU/100mL when perched seasonal water table is present. This dissertation explored several concerns associated with this regulation: 1) is 15 cm of unsaturated soil sufficient to protect ground water? 2) is wastewater reuse through spray irrigation safe when shallow water tables are present? 3) do subsurface drainage system enhance or limit the removal or transport of pathogens to ground and surface water? 4) is disinfection of reused wastewater effective in protecting the public health? Soil microcosms were established to investigate the effects of soil depth to remove microbial pollutants under winter soil conditions. This study demonstrated that very shallow soils (15 cm) did not achieve three orders of magnitude of E. coli. The 22.5 and 30 cm of soil depths did not increase removal efficiency of E. coli. This result showed that using very shallow soils (15cm) may not provide adequate attenuation to protect ground water. The additional disinfection methods need to be applied when use 15 cm of soil. Natural movement of microbial pollutants through subsurface drainage system and groundwater was monitored at the Deer Creek State Park irrigation field. The soil depth at 60 ~ 90 cm had no capacity to remove microbial pollutants potentially due to higher application rate, preferential flow and seasonally high water table. The potential for ground water contamination exists and subsurface drainage water can become a nonpoint source of microbial pollution to receiving water bodies when irrigation applies.Evaluating the efficiency of an onsite wastewater reuse system (OWRS) is required to meet onsite disinfection needs and protect public health. The OWRS with batch chlorination achieved the complete removal of E. coli and moderate removal of F-specific coliphages and C. perfringens. Molecular-based analyses showed that OWRS removed 3.1 and 2.3 orders of magnitude of pathogenic bacteria and antimicrobial resistance bacteria. This result demonstrated that OWRS with batch chlorination can be a useful option to treat wastewater in addition to soils under wet and cold conditions.The microbial risks associated with landscape irrigation were characterized using quantitative microbial risk assessment (QMRA). QMRA results showed that disinfected reclaimed water don’t pose bacterial infection risks. The indirect ingestion by touching plants and lawns and inhalation by aerosolized can pose viral and protozoan infection risks. For those viruses and protozoa, additional protection means/regulation such as barrier and sufficient setback distance will be required to prevent the human exposure to them and thus to minimize the potential health risks associated with them. In summary, this dissertation indicates the potential health risks using very shallow and seasonally wet and cold soils and recommends the efficient and sustainable interventions to treat wastewater while minimizing the public health risks and the contamination of water resources in rural areas not only of Ohio, but also of regions with the similar climate and soil conditions across the world."],"dc:format":["application/pdf","p.151","1.87 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1440451065"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Environmental Health","Public Health","Water Resource Management","Wastewater reuse","soil","groundwater","onsite wastewater reuse system","batch chlorination","peat biotreatment","pathogen removal","coliphage","Clostridium perfringens"],"dc:title":["Wastewater Reuse: Comprehensive Study about Treatment System Efficiency and Potential Public Health Concerns"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Public Health"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:40:38Z"}