{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1452224451"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1452224451","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Liver Segmentation by Geometric and Texture features using Support Vector Machine (LiGTS)","abstract":"Magnetic resonance elastography (MRE) is a novel, non-invasive technique to measure the stiffness of soft tissue. In MRE, mechanical vibrations are induced in the region of interest (ROI), which are then encoded in the phase of an MR image. These wave images are further processed to obtain a spatial stiffness map. The work presented in this thesis is focused on segmenting the liver to facilitate stiffness quantification for staging liver fibrosis. The current practice requires an expert radiologist to segment the liver in MRE scans so that the stiffness computation can be performed within the liver. In addition to being labor intensive, this manual intervention causes inter- and intra-observer variability in drawing the boundaries of the liver and thus impacts the computed stiffness values. Hence, there is a need to increase the consistency of the stiffness computation process, which will enhance the clinical effectiveness of the MRE-based stiffness computation. Automating the segmentation process can improve repeatability and eliminate inter- and intra-observer variability, providing the desired consistency for MRE-based stiffness quantification. In this work, an automated method for liver segmentation is presented. The method is based on supervised learning and employs a combination of geometric and texture-based features in conjunction with support vector machine-based classification. For validation, liver MRE is performed in 14 healthy volunteers. For performance evaluation, results from automated segmentation are analyzed in terms of error rate, sensitivity, specificity, and precision, with manual segmentation providing the ground truth. The results show that the proposed automated segmentation method has an error rate of less than 4%. Also, the mean stiffness values derived from the proposed method are in good agreement with the values obtained from a manually drawn ROI. In summary, this study demonstrates and validates a new segmentation method for liver MRE.","abstract_html":"Magnetic resonance elastography (MRE) is a novel, non-invasive technique to measure the stiffness of soft tissue. In MRE, mechanical vibrations are induced in the region of interest (ROI), which are then encoded in the phase of an MR image. These wave images are further processed to obtain a spatial stiffness map. The work presented in this thesis is focused on segmenting the liver to facilitate stiffness quantification for staging liver fibrosis. The current practice requires an expert radiologist to segment the liver in MRE scans so that the stiffness computation can be performed within the liver. In addition to being labor intensive, this manual intervention causes inter- and intra-observer variability in drawing the boundaries of the liver and thus impacts the computed stiffness values. Hence, there is a need to increase the consistency of the stiffness computation process, which will enhance the clinical effectiveness of the MRE-based stiffness computation. Automating the segmentation process can improve repeatability and eliminate inter- and intra-observer variability, providing the desired consistency for MRE-based stiffness quantification. In this work, an automated method for liver segmentation is presented. The method is based on supervised learning and employs a combination of geometric and texture-based features in conjunction with support vector machine-based classification. For validation, liver MRE is performed in 14 healthy volunteers. For performance evaluation, results from automated segmentation are analyzed in terms of error rate, sensitivity, specificity, and precision, with manual segmentation providing the ground truth. The results show that the proposed automated segmentation method has an error rate of less than 4%. Also, the mean stiffness values derived from the proposed method are in good agreement with the values obtained from a manually drawn ROI. In summary, this study demonstrates and validates a new segmentation method for liver MRE.","abstract_has_math":false,"creators":["Bhatnagar, Kovid"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Kolipaka, Arun","Ahmad, Rizwan"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-06-08","date_published":"2016-06-08","updated_at":"2026-11-27T04:40:52Z","subjects":["Electrical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1452224451","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1452224451","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1452224451","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1452224451","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kolipaka, Arun","Ahmad, Rizwan"]},{"key":"dc:creator","label":"Author","values":["Bhatnagar, Kovid"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-06-08"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1452224451"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Magnetic resonance elastography (MRE) is a novel, non-invasive technique to measure the stiffness of soft tissue. In MRE, mechanical vibrations are induced in the region of interest (ROI), which are then encoded in the phase of an MR image. These wave images are further processed to obtain a spatial stiffness map. The work presented in this thesis is focused on segmenting the liver to facilitate stiffness quantification for staging liver fibrosis. The current practice requires an expert radiologist to segment the liver in MRE scans so that the stiffness computation can be performed within the liver. In addition to being labor intensive, this manual intervention causes inter- and intra-observer variability in drawing the boundaries of the liver and thus impacts the computed stiffness values. Hence, there is a need to increase the consistency of the stiffness computation process, which will enhance the clinical effectiveness of the MRE-based stiffness computation. Automating the segmentation process can improve repeatability and eliminate inter- and intra-observer variability, providing the desired consistency for MRE-based stiffness quantification. In this work, an automated method for liver segmentation is presented. The method is based on supervised learning and employs a combination of geometric and texture-based features in conjunction with support vector machine-based classification. For validation, liver MRE is performed in 14 healthy volunteers. For performance evaluation, results from automated segmentation are analyzed in terms of error rate, sensitivity, specificity, and precision, with manual segmentation providing the ground truth. The results show that the proposed automated segmentation method has an error rate of less than 4%. Also, the mean stiffness values derived from the proposed method are in good agreement with the values obtained from a manually drawn ROI. In summary, this study demonstrates and validates a new segmentation method for liver MRE."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.67","6.95 MB"]},{"key":"dc:title","label":"Title","values":["Liver Segmentation by Geometric and Texture features using Support Vector Machine (LiGTS)"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kolipaka, Arun","Ahmad, Rizwan"],"dc:creator":["Bhatnagar, Kovid"],"dc:date":["2016-06-08"],"dc:description":["Magnetic resonance elastography (MRE) is a novel, non-invasive technique to measure the stiffness of soft tissue. In MRE, mechanical vibrations are induced in the region of interest (ROI), which are then encoded in the phase of an MR image. These wave images are further processed to obtain a spatial stiffness map. The work presented in this thesis is focused on segmenting the liver to facilitate stiffness quantification for staging liver fibrosis. The current practice requires an expert radiologist to segment the liver in MRE scans so that the stiffness computation can be performed within the liver. In addition to being labor intensive, this manual intervention causes inter- and intra-observer variability in drawing the boundaries of the liver and thus impacts the computed stiffness values. Hence, there is a need to increase the consistency of the stiffness computation process, which will enhance the clinical effectiveness of the MRE-based stiffness computation. Automating the segmentation process can improve repeatability and eliminate inter- and intra-observer variability, providing the desired consistency for MRE-based stiffness quantification. In this work, an automated method for liver segmentation is presented. The method is based on supervised learning and employs a combination of geometric and texture-based features in conjunction with support vector machine-based classification. For validation, liver MRE is performed in 14 healthy volunteers. For performance evaluation, results from automated segmentation are analyzed in terms of error rate, sensitivity, specificity, and precision, with manual segmentation providing the ground truth. The results show that the proposed automated segmentation method has an error rate of less than 4%. Also, the mean stiffness values derived from the proposed method are in good agreement with the values obtained from a manually drawn ROI. In summary, this study demonstrates and validates a new segmentation method for liver MRE."],"dc:format":["application/pdf","p.67","6.95 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1452224451"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Electrical Engineering"],"dc:title":["Liver Segmentation by Geometric and Texture features using Support Vector Machine (LiGTS)"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:40:52Z"}