{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1462889408"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1462889408","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"RELAP5 Model Benchmark for Thermal Performance of DRACS Test Facilities","abstract":"Direct Reactor Auxiliary Cooling System (DRACS), a passive safety system proposed for Fluoride-salt-cooled High-temperature Reactors (FHRs), is driven by natural convection/circulation to remove the decay heat during accidents. Two test facilities were designed and built following a scaling analysis at The Ohio State University to test the thermal performance of the DRACS, including a low-temperature DRACS test facility (LTDF) and a high-temperature DRACS test facility (HTDF). RELAP5 MOD 4.0 is utilized to model the DRACS thermal performance and predict the heat removal capability of the LTDF and HTDF. The code results are benchmarked with the experimental data obtained from the LTDF, which uses water as a surrogate for both primary and secondary fluids in DRACS. Two transient scenarios have been investigated, including a startup scenario and a pump trip scenario. Comparisons between the experimental data and simulation results from the RELAP5 show good agreement.The HTDF uses FLiNaK and KF-ZrF4, respectively, as the working fluids for the scaled down DRACS primary and secondary loops. Fluid properties of FLiNaK and KF-ZrF4 have been implemented into the RELAP5 code. Startup and pump trip scenarios in the HTDF are also simulated by the code.","abstract_html":"Direct Reactor Auxiliary Cooling System (DRACS), a passive safety system proposed for Fluoride-salt-cooled High-temperature Reactors (FHRs), is driven by natural convection/circulation to remove the decay heat during accidents. Two test facilities were designed and built following a scaling analysis at The Ohio State University to test the thermal performance of the DRACS, including a low-temperature DRACS test facility (LTDF) and a high-temperature DRACS test facility (HTDF). RELAP5 MOD 4.0 is utilized to model the DRACS thermal performance and predict the heat removal capability of the LTDF and HTDF. The code results are benchmarked with the experimental data obtained from the LTDF, which uses water as a surrogate for both primary and secondary fluids in DRACS. Two transient scenarios have been investigated, including a startup scenario and a pump trip scenario. Comparisons between the experimental data and simulation results from the RELAP5 show good agreement.The HTDF uses FLiNaK and KF-ZrF4, respectively, as the working fluids for the scaled down DRACS primary and secondary loops. Fluid properties of FLiNaK and KF-ZrF4 have been implemented into the RELAP5 code. Startup and pump trip scenarios in the HTDF are also simulated by the code.","abstract_has_math":false,"creators":["Lin, Hsun-Chia"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Nuclear Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sun, Xiaodong"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-10-24","date_published":"2016-10-24","updated_at":"2026-11-27T04:41:05Z","subjects":["Nuclear Engineering","DRACS, FHR, RELAP5, AHTR"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1462889408","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1462889408","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1462889408","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1462889408","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sun, Xiaodong"]},{"key":"dc:creator","label":"Author","values":["Lin, Hsun-Chia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-10-24"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Engineering","DRACS, FHR, RELAP5, AHTR"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1462889408"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Direct Reactor Auxiliary Cooling System (DRACS), a passive safety system proposed for Fluoride-salt-cooled High-temperature Reactors (FHRs), is driven by natural convection/circulation to remove the decay heat during accidents. Two test facilities were designed and built following a scaling analysis at The Ohio State University to test the thermal performance of the DRACS, including a low-temperature DRACS test facility (LTDF) and a high-temperature DRACS test facility (HTDF). RELAP5 MOD 4.0 is utilized to model the DRACS thermal performance and predict the heat removal capability of the LTDF and HTDF. The code results are benchmarked with the experimental data obtained from the LTDF, which uses water as a surrogate for both primary and secondary fluids in DRACS. Two transient scenarios have been investigated, including a startup scenario and a pump trip scenario. Comparisons between the experimental data and simulation results from the RELAP5 show good agreement.The HTDF uses FLiNaK and KF-ZrF4, respectively, as the working fluids for the scaled down DRACS primary and secondary loops. Fluid properties of FLiNaK and KF-ZrF4 have been implemented into the RELAP5 code. Startup and pump trip scenarios in the HTDF are also simulated by the code."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.117","4.78 MB"]},{"key":"dc:title","label":"Title","values":["RELAP5 Model Benchmark for Thermal Performance of DRACS Test Facilities"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sun, Xiaodong"],"dc:creator":["Lin, Hsun-Chia"],"dc:date":["2016-10-24"],"dc:description":["Direct Reactor Auxiliary Cooling System (DRACS), a passive safety system proposed for Fluoride-salt-cooled High-temperature Reactors (FHRs), is driven by natural convection/circulation to remove the decay heat during accidents. Two test facilities were designed and built following a scaling analysis at The Ohio State University to test the thermal performance of the DRACS, including a low-temperature DRACS test facility (LTDF) and a high-temperature DRACS test facility (HTDF). RELAP5 MOD 4.0 is utilized to model the DRACS thermal performance and predict the heat removal capability of the LTDF and HTDF. The code results are benchmarked with the experimental data obtained from the LTDF, which uses water as a surrogate for both primary and secondary fluids in DRACS. Two transient scenarios have been investigated, including a startup scenario and a pump trip scenario. Comparisons between the experimental data and simulation results from the RELAP5 show good agreement.The HTDF uses FLiNaK and KF-ZrF4, respectively, as the working fluids for the scaled down DRACS primary and secondary loops. Fluid properties of FLiNaK and KF-ZrF4 have been implemented into the RELAP5 code. Startup and pump trip scenarios in the HTDF are also simulated by the code."],"dc:format":["application/pdf","p.117","4.78 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1462889408"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Nuclear Engineering","DRACS, FHR, RELAP5, AHTR"],"dc:title":["RELAP5 Model Benchmark for Thermal Performance of DRACS Test Facilities"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Nuclear Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:41:05Z"}